HomeMy WebLinkAboutEngineered Plan - 2002SLAB SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE <NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM •75' OF COVER OVER PRECAST /_ WITHIN 6' OF FIN• GRADE 2% SLOPE REQUIRED OVER SYSTEM 42,P RUN FOR PIIPE RSTLEVEL 2� bOUBLE WASHED PEASTON EXIST. 1000 �' 40.1' GALLON SEPTIC 40.5'±tTn TANK (H- 10 ) GAS 39.69' o 4' AT SIDES (RE -USE) BAFFLE 39 $6' �� 39.68 0.58' 3' AT ENDS 6' CRUSHED STONE OR MECHANICAL$ bo 39.1' COMPACTION. (15.221 C23)- DEPTH OF FLOW = 4�.__... < 1.5y° SLOPE) (_!_7 SLOPE) TEE SIZES 3/4' TO 1 1/2" DOUBLE WASHED STONE INLET DEPTH = 10' OUTLET DEPTH 14" 4' LEACHING FOUNDATION-- EXIST. SEPTIC TANK 41' -�-- D' BOX 3' FACILITY i USE ADJUSTED WATER AT EL. 35.1' offf 60" 92 i 4T.2 49.0 .102„ / /46.7 L=67.51' \ R=45.53' \ \ (1 / 9 46.3 45.8 6 -- 50.9 136„ 45.2 \ LOT 23 45 19,629± SQ. FT. \\ �1� �' 150" TEST HOLE LOGS ENGINEER. RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: JUNE 12, 2002 PERC. RATE _ < 5 MIN/INCH IN COS CLASS I & II SOILS P# FILL VERC1XZ Y FINE L 2.5Y 6/3 / C2 7.5YR 5/8 1" PLATES BOG IRON C3 COS VERY FINE SAND OBSGW 5Y 6/2 30% FIRM 54 fdG�. 94' 0.3' 29.2' 144„ FILL Bw 0/0 �LNi S /1OYR 5/8 VERY FINE Sc 2.5Y 6/3 C2 COS 2.5Y 6/4 43.3' �D LOCUS I DoT LOCATION MAP NTS ASSESSORS MAP 143 PARCEL 49 WELL: AI W 247 ZONE: 8 ADJ: 5.8' VARIANCES REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1o: REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') 35.4' lb: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' / 44 NO GW OBS. N u I L J / �N 44.3 44.6 \ / 43.9 43 ��\ SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) 1. DATUM IS APPROXIMATED FROM QUAD MAP PRIVATE UNDERGROUND \ -- / 43 t,: - ELECTRIC NOT MARKED AT \ rlti�E OF TEST HOLE D► -SIGN _ FLOW: 3 64DROOMS ( 110 GPD> = 330 GPD 2. MUN C iAL 'WA Ef­ iS_ EXISTING - - 2.8 \�_• U:�E A 330 i GPD DESIGN FL❑4h ° 3. .�IININ:iJM PIPE Pi TCr; I❑ Bt.' i/�3' PER F C1L, 43.x! 43. \\"4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10, \ SEPTIC TANK ,330 GPD < 2 ) 660' 5. PIPE' JOINTS TO BE MADE WATERTIGHT. / " 42.3 43.3 BENCHMARK: USE SLAB �O\ 1000 s / ELEVATION AT 42.5' op, \ U`:E'.A 0 GALLON SEPTIC TANK; (REUSE -EXIST.) 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. / 7 41.9 \ L-1 ACHING ENVIRONMENTAL CODE TITLE V. o \ 2 37.25 °+ 10.83) .58 (.74) - 41 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT �1 \ SIDES: TO BE USED FOR ANY OTHER PURPOSE, 41.6 GRAVEL `w W\ 37.25P x `10.83 (.74) 298 " DRIVE �� v5 \ BI.�TTOM: 8. PIPE FOR SEPTIC SYSTEM T❑ SCH, 40-4 PVC. 18" OAK i 42s ��� FSPG TOTAL: F. 39 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT s3•B S.3,.GPD PSGINSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED �o RC BEAN N 244 EXIST. DWELL. o`� USE 5 STA�JDARD INFILTRATORS WITH 4' STONE AT SIDES FROM BOARD OF HEALTH. �9.8 TH15041.7 PG5 A U D 3' AT 'ENDS 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING _. _. .6 ORANGE E� FAILED LEACH PITS + + 42.2 'h SyR + �a,/ _-L-EGEND T.I TL E 5 SITE PLAN + 43.3 + 18" OAK 100.0 il PROPOSED SPOT ELEVATION OF mss, ARGE P.PINES + 44.3' 11 C OLLI N G WOOD DRIVE + 43. \ 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF: sr� + 1. y 4 s _ 00 PROPOSED CONTOUR YARMOUTH(PORT) + +.0 N$ RE -LOCATE .1 \ 03.8 + 44.1�`�. ---- 100 EXISTING CONTOUR PREPARED FOR: PAULA MacLELLAND SHED \ + 43. \ \ D� EXISTING 1000 GAL. SEPTIC TANK 20 0 20 40 60 \ b�� (RE -USE) BOARD OF HEALTH THX N9) + 4 8. 8 7 ;�VV2 - w MA„ , FSP ROVED DATE SCALE: 1 20 DATE: JUNE 15, 2002 5' REMOVAL OF UNSUITABLE SOIL REOUIRED + 42. 43• AROUND PERIMETER OF LEACHING FACILITY, ' 0 � DOWN TO SUITABLE SOIL (COARSE SAND) off 908-362-4541 _ / p^. _ ._ fax 508 362-9880 Q E C E 9 V E DD LAYER.. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL AA mOF M JUL 2 Z 2002 do wn cape engineering, c, ����" �'�� �tH OF 45.0 Mq o� ARNEyes ���� HEALTH DEPT. CIVIL ENGINEERS oJALA y ALA LA y� e No. 26 8 o VILc- ' . �..:_. ._ .. ,. LAND SURVEYORS �o� '�fCl `�o Qy`� 2 02-- 151 939 main st. yarmouth, ria 02675 ,q g, 0 sin G` .t.S. DATE