Loading...
HomeMy WebLinkAboutEngineered Plan - 2019ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. NOTE: A 1955 ROAD LAYOUT TOOK A PORTION OF THIS LOT. LO M IL rn 0 0 M z a J o_ MAX FEASIBLE COMPLIANCE APPROVALS 1. RESERVE AREA NOT .SHOWN. 310CMR 15.248 UTILITY = KIT. BDRM a DNRM m -C BDRM BDRM LVRM FLOOR PLAN NOT TO SCALE LEGEND N /F OCONNOR •-�u,5 g12�± 1 ,,-1 0.4 X 4\9.842 3 1 83 ........ .. 1 0 1 1 1 TING ov 20,00 1 P PRK 1 15 '� sE 'gg11 0 rr 1'�gO20.1 x,10 3 1 / 1`� m V� 1918 19.780 N 20.1 1 _c 20.3 3.0 19.5 x,o LOT 0 111 x 20, 03 19.4 8480 S. F.19..:.1: 71:. 1 N BENCH MARK --TOP SW CORNER OF CONCRETE STOOP=20.03 ASSIGNED N /F WALDRON 1x 15, s\ :.:.. x 20.0511 x 20.0 20.0 EX. :. 1-GAZEBQ- `I .720.1 ti019. ( n 1\ x 20.0- v ` x 19.tr'x 1918 j �o_ \2 1E:0 _ 9.95 r . -�� 8-_- = 19__ 19.90 �� 20.041> o ox:. NT 1 -1 _ .:.9.7 �, 1.51± 20.00 ��.� 3�, -- x 20.0 9.8 19.64 X 19.80i -� 1 1 53-1'9,59 i �-X19.131 Ix 19.97 x 19,63 �--_ I X 19.88 X 19.79 REMOVE EXISTING LEACHING AND CLOGGED STONE WITH IN 5' OF NEW LEACHING TEST HOLE LOCATION, NUMBER WATER LINE FLAGS EXIST. & PROP. ELEVATIONS ('X' MARKS POINT) EXISTING CONTOUR PROPOSED CONTOUR UTILITY POLE (IF SHOWN) EXISTING DRAINAGE CATCH BASIN FENCE (IF SHOWN, NOT ALL SHOWN) TREE (IF SHOWN, NOT ALL SHOWN) BENCH MARK --TOP, BACK, CENTER OF SEPTIC TANK=18.64 ASSIGNED TEST HOLE DATE: April 4, 2019 6" PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: Amy Von Hone, RS, CHO 18" PERC RATE: <2'-00"/inch (C layer) SOIL SURVEY(1993): Carver coarse sand GEOLOGIC MAP(1986): Harwich outwash plain deposits 32"32" Invert 17.22± 2-500 GALLON DRY WELLS Existing Invert 16.97 H-10 Use Gas Baffle Top Units=17.5 Proposed _ min. cover Top Stone=17.1 -- - I-( Existing I S=1 /4" eft f_ _. 6" Max. 1 1000 Gat.=Proposed Septic TankL---------I6" Stone or compact i- 4' 131 ,- I I I-1 a) DESIGN DATA BEDROOMS: 3 GARBAGE GRINDER: - - -- No-- REQUIRED o=- REQUIRED CAPACITY: 330 GPD EXISTING SEPTIC TANK: 1000 GAL. LEACHING AREA: 479 S.F. BOTTOM AREA: (29' X 11')=319 SF SIDE AREA: (29' + 11')2 X 2'=160 SF CAPACITY: 354 GPD 479 SF X 0.74 GPD/SF THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN O-RWANAL RED STAP AND SIGNATURE. HEALTH AGENT APPROVAL Yzrmonth Hen1th Department le "'Imp WE Date 130" 24" T 24" 132" 14.7 5.2' Bottom High Groundwater=9.5 0.7' Adjustment Mash29 Zone A March 2019 Observed Water=8.8 LEACH AREA USE 2 DRY WELLS SET 4' APART WITH APPROX. 3' OF STONE ON THE SIDES AND 4' ON THE ENDS TO MAKE A 29' X 11' X 2' DEEP LEACH AREA. SITE PLAN FOR ANGELA LENTROS A layer 10yr',5/2 loamy sand B1 layer 10yr 5/8 sandy loam B2 layer 1Oyr 5/8 loamy sand C layer 10yr 6/8 med. coarse ',sand i __observed water _ 4 APR. U 5 Z019 i ' i..A1_TH DEPT LOT 10, 30 LOCUST STREET, SOUTH. YARMOUTH, MA APRIL 5, 2019 SCALE: 1 "=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 DATE (508) 775-9700 PAGE 1 OF 1 C- 2016 BY R.J. CADILLAC NOTES Lentros2.dwg St. 1. LOCUS IS A.M. 42, PARCEL 254. F834/20 SB14/57 willow 50 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(OUTSIDE 0.2% RISK) ON FIRM DATED JULY 16, 2014. c o 4. ALL. PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) N fl 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER.r' 0 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. p 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3'., OR VENTING MUST BE PROVIDED. NOT TO COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING SCALE 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND -FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(fee 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 19.6 TEST HOLE DATE: April 4, 2019 6" PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: Amy Von Hone, RS, CHO 18" PERC RATE: <2'-00"/inch (C layer) SOIL SURVEY(1993): Carver coarse sand GEOLOGIC MAP(1986): Harwich outwash plain deposits 32"32" Invert 17.22± 2-500 GALLON DRY WELLS Existing Invert 16.97 H-10 Use Gas Baffle Top Units=17.5 Proposed _ min. cover Top Stone=17.1 -- - I-( Existing I S=1 /4" eft f_ _. 6" Max. 1 1000 Gat.=Proposed Septic TankL---------I6" Stone or compact i- 4' 131 ,- I I I-1 a) DESIGN DATA BEDROOMS: 3 GARBAGE GRINDER: - - -- No-- REQUIRED o=- REQUIRED CAPACITY: 330 GPD EXISTING SEPTIC TANK: 1000 GAL. LEACHING AREA: 479 S.F. BOTTOM AREA: (29' X 11')=319 SF SIDE AREA: (29' + 11')2 X 2'=160 SF CAPACITY: 354 GPD 479 SF X 0.74 GPD/SF THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN O-RWANAL RED STAP AND SIGNATURE. HEALTH AGENT APPROVAL Yzrmonth Hen1th Department le "'Imp WE Date 130" 24" T 24" 132" 14.7 5.2' Bottom High Groundwater=9.5 0.7' Adjustment Mash29 Zone A March 2019 Observed Water=8.8 LEACH AREA USE 2 DRY WELLS SET 4' APART WITH APPROX. 3' OF STONE ON THE SIDES AND 4' ON THE ENDS TO MAKE A 29' X 11' X 2' DEEP LEACH AREA. SITE PLAN FOR ANGELA LENTROS A layer 10yr',5/2 loamy sand B1 layer 10yr 5/8 sandy loam B2 layer 1Oyr 5/8 loamy sand C layer 10yr 6/8 med. coarse ',sand i __observed water _ 4 APR. U 5 Z019 i ' i..A1_TH DEPT LOT 10, 30 LOCUST STREET, SOUTH. YARMOUTH, MA APRIL 5, 2019 SCALE: 1 "=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 DATE (508) 775-9700 PAGE 1 OF 1 C- 2016 BY R.J. CADILLAC