Loading...
HomeMy WebLinkAboutReview Checklist = TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST t.Location: A.M. Lot 3 Zone of Contribution: In_ Out creage / Commercial: Residential: ! Street: SMr / / -i �„ Village: Dr15 - QG , Floor Plan: #Bedrooms: 1 vimisw- Owner: (' . 4//S 5;‘,-777-� Installer: 7 Address: Phone: Phone: Builder: Engineer: a(0/6-1911',749,1/,€ €-Zg Address: 7- Phone: _ii) ��"6 't; 3 Phone: /5 k t N/ANO 1.Required#of copies received J 2.Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table Zi^ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �� 5. Water line 10 ft from septic components Var.: t_ 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: (O' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: c_...---9. Leaching minimum 100 ft from wetlands Var.: 7..5,-(--- C___._ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: (......---- 11. ,„ - 11.Tank/leaching minimum 10 ft from property line Var.: e "�r (T C-.-- 12. System meets all other setback requirements Var.: q . : ) J 13.Uses adjustment for maximum high groundwater Var.: j L/ 14.Leaching set 4-5 ft above adj.water or bottomof Var.: v 15. System not in top or subsoil(A,B horizons) o 'rem ;i/" 16.Proposed contours are suitable t-•-'' 17. System meets slope requirements-min. 1/8", ' "preferred 1/' 18. System meets breakout requirements PVC liner:- ( Wall:` -ft i Z/ 19. Specified tee sizes are proper, gas baffle on outlet tee t/'_ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal r 22. System adequately sized for its intended use C 23.Minimum 6"stone or compacted below tank and dbox 1-.-- ' 24.Manhole covers within 6"of grade,pump chamber cover to grade t-/ 25.Inspection port on plastic chambers/leach field L- - 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size t/ 28. Septic tank/pump chamber to be factory waterproofed L. � - 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber U/� 31.Engineer to inspect and certify soils: wall: commercial: V 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �, -" 33.H-20 loading is subject to vehicular traffic, groundwater L� 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house t.�� 36.Deed Restriction required max. #bedrooms: max. flow: gpd (-------- 37. -137.Check area lots for groundwater/Label groundwater in Assessor's Ma to ....-- Plan Plan reviewed by: 6/03/03