HomeMy WebLinkAboutReview Checklist 4 z2 -7 9
TOWN OF YARMOUTH
/' SEWAGE PLAN REVIEW CHECKLIST
. Location: A.M. /�(p Lot 0 Zone of Contribution: In Out Acreage
Commercial: Residential: 1/4---'
Street: /7/ Gf`
Village: Floor Plan: k #Bedrooms: 1
Owner: � s" 444-e- Installer: *e0,:rta(/*-4V/11Address: Phone: -»�j 9 ^ l% �Phone:
Builder: 7 Engineer: � #%,_ ,,,41;t$'
Address: Phone:
Phone: '0 �X r Feee d y-)
N/A YES NO
1.Required# of copies received
2. Date of soils exam and percolation test not older than 2 years � , _
3. 4-5 ft of naturally occurring pervious material, above water table `------ _
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �..---' _
5. Water line 10 ft from septic components Var.: Lam,
6.Benchmark indicated and shown-NGVD if near wetlands (----
7. Septic tank minimum 10 ft from foundation, deck Var.: IL-,
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: `„----.
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -
11.Tank/leaching minimum 10 ft from property line Var.: %.------•
12. System meets all other setback requirements Var.: �-•
13.Uses adjustment for maximum high groundwater Var.: 1,..--.
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: k..--
15.
s15. System not in top or subsoil(A,B horizons) or 5' removal L.,-----
16.Proposed contours are suitable /�44 CM
17. System meets slope requirements-min. 1/8", '/4"preferred , / 1/4._---
18. System meets breakout requirements PVC liner: Wall: L.•
19. Specified tee sizes are proper, gas baffle on outlet tee L�
20. Sewage is under 10,000 gpd for parcel t.-----
21.No garbage disposal L...-----
22. System adequately sized for its intended use �.i
23. Minimum 6"stone or compacted below tank and dbox -
24.Manhole covers within 6"of grade,pump chamber cover to grade �..-•
25. Inspection port on plastic chambers/leach field L_----'
26. Electrical permit for pump chamber/Separate meter for duplexes c.....-----
27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size 4------
28.
_28. Septic tank/pump chamber to be factory waterproofed L---'
29. Vent provided if leaching below 3 feet, under driveway/parking `,_--,
30.Buoyancy calculations for tank/pump chamber ‘......---
31. Engineer to inspect and certify soils: wall: commercial: ..........--
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature �`
33. H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature - �------.
35.Foundation footing min. 2 feet above adjusted ground water for new house ��-
36. Deed Restriction required max. #bedrooms: max. flow: gpd .- -
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03