Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST • Location: AM 2 LOT A/7 Date of Subdivision App val Street .S.3 C . /'s WJ i�c/ Zone of Contribution- Out Village t0• aiyyiiCommercial Residential Owner: Ao,Yf Piaft Installer 7 -64 Builder: Engineer C4.--le,--ea-e-' 775-- 97o-O N/A YES NO 1. Required number of copies received. 2. Date of soils exam and percolation test not older than 2 years. 3. 4 feet of naturally occurring pervious material, above water table(new construction) 4. Foundation 2 feet above high point of fronting road for new construction. x' - 5. Water availability letter from Water Department for new construction. 6. Benchmark indicated and shown-NGVD if near wetlands. 7. Building sewer does not exit center of house. 8. Septic tank a minimum of 10 feet from house and deck. X 9. Leaching a minimum of 20 feet from house and 10 feet from deck. X 10. Leaching a minimum of 100 feet from wetlands. �,i�,K.i vG )(11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. >C 2. S stem me-ts all ether setb.ck r-a u. - • ents. A.,., , , ' AM LI A.<., . _� _ 13. Uses adjustment for maximum hig groundwater. Ne 14. Leaching 4 -5 feet above adjusted water table or bottom of test pit. 15. System not in top or subsoil or 5 foot removal. 16. Proposed contours are suitable. 17. System meets slope requirements - min. 1/8". 1/4" preferred. 18.. System meets breakout requirements- peastone elevation carried out 15 feet minimum. 19. Specified tee sizes are proper. gas baffle on outlet tee. 20:Sewage flow under 10.000 gpd for parcel. -i. 21;No garbage disposal. 22. System adequately sized for its intended use. _1*23.-Minimum 6" stone or mechanically compacted below the tank and d-box. 24. Manhole covers within 6" of grade - septic tank and pump chamber. Y 25. Electrical permit for pump chamber. 26. Pump system - 2" line, weep hole, check valve, sanitary in d-box. alarm on separate circuit. ( 27. Septic tank and pump chamber to be Factory waterproofed. 28. Vent provided if leaching below 3 feet or under driveway orparking. 29. Engineer to inspect and certify : A. clay removal ,?, b. wall construction schedule c. commercial system 30. Engineer and Land Surveyor stamp and signature. 1 31. H2O loading when system subject to vehicular traffic. 32. Title V application and fee signed by a licensed installer. A.4.44-.1 ote-ito-L1,v1_4i ,t4 'X' 33. Foundation footing 2 feet above adjusted water table. 34. Lot subdivided prior to July 31. 1986 - Nitrate Loading. 35. Subdivided prior to April 7. 1989 - Phosphorus Zone 300'. Plan reviewed by: '_/