HomeMy WebLinkAboutReview Checklist TOWN QF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 9f Zone of Contribution: In_ Out '-" Acreage
Commercial: Residential:,o
Street: 6�/1 /i// . - 4*/
Village: (JJ'_ � , Floor Plan: /// # Bedrooms: 5
Owner: I'or l-(-, 4a_ Installer: d daldiC
Address: Phone: c-a- 4 -2 SS,t
Phone: � `
%f ; t41` -- / <¶/rS
'
Builder: Engineer:
V
Address: Phone: 5-- 3G L - �C j -
Phone: Tiij,X /-7-,-.-'3(Y Ck=
,Z4' G7c_.--
N/A YES NO
1. Required#of copies received - 1.40"'
2. Date of soils exam and percolation test not older than 2 years L.-----
3.
_..3. 4-5 ft of naturally occurring pervious material, above water table t......----
4.
../4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: t....-----
6.
_/6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.: L�.i'
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: `.../
11. Tank/leaching minimum 10 ft ,
from property line Var.: ( ,`1!_ 776-(--fZL C _-%' ---'
12. System meets all other setback requirements Var.: tom,/
13. Uses adjustment for maximum high groundwater Var.: �- .
14. Leaching set 4-5 ft above adj. water or bolt of test holes ,Var.: i �,�
15. System not in top or subsoil(A,B horizons) r 5' remgyal'
16.Proposed contours are suitable t.....----
17.
/17. System meets slope requirements-min. 1/8", '/4"preferred k..---
18.
_f18. System meets breakout requirements PVC liner: Wall: ,,/"
19. Specified tee sizes are proper, gas baffle on outlet tee l------
20. Sewage is under 10,000 gpd for parcel t....----
21.No garbage disposal 1/4.....----
,
22. System adequately sized for its intended use ----
23. Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade I„_---
25. Inspection port on plastic chambers/leach field L�--.--
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole,check valve,tee in dbox,pump size .----
28. Septic tank/pump chamber to be factory waterproofed _-----
29. Vent provided if leaching below 3 feet, under driveway/parking
30. Buoyancy calculations for tank/pump chamber �.
31. Engineer to inspect and certify soils: wall: commercial: .------
32.
�32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular,traffic, groundwater ____,--
34.
�34. Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house - ---
36. Deed Restriction required max. #bedrooms: max. flow: gpd_ ------- -,..-
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: cl;
' 6/03/03