Loading...
HomeMy WebLinkAboutReview Checklist 6.- '1) 77 TOWN OF YARMOUTH • SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 7' / Zone of Contribution: In Out_Acreage Commercial: Residential: {D Street: f A i// /// Village: J - / Floor Plan: #Bedrooms: d Owner: max Q Installer: 7 sC f U f e7-7-7Address: �"!� Phone: Phone: Builder: Engineer: 5 ' zit,i" a ll.fr Address: Phone: '7"5-11- c-�--5krP 66 Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years t..------- 3.4-5 .-------3.4-5 ft of naturally occurring pervious material, above water table t_.-✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: (...,-'-- 5. .r.f5.Water line 10 ft from septic components Var.: L---� 6.Benchmark indicated and shown-NGVD if near wetlands (..-/ 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: '" 11.Tank/leaching minimum 10 ft from property line Var.: � -✓ 12.System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: %.--/ • 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: v___-.---- 15.System not in top or subsoil(A,B horizons)or 5' removal 1/4------ 16.Proposed contours are suitable l--� 17. System meets slope requirements-min. 1/8", 1/4"preferred k....---''r 18. System meets breakout requirements PVC liner: Wall: �----- 19. Specified tee sizes are proper, gas baffle on outlet tee c_✓'-- T20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal (.- 22. System adequately sized for its intended use L/' 23.Minimum 6"stone or compacted below tank and dbox C....----- 24. .o_✓24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field -- 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed , - 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: .f ' 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature J 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature •- 35.Foundation footing min.2 feet above adjusted ground water for new house _/ 36.Deed Restriction required max. #bedrooms: max. flow: gpd (-_,-` 37.Check area lots for groundwater/Label groundwater in Assessor's Map -''�! Plan reviewed by: 6/03/03