Loading...
HomeMy WebLinkAboutReview Checklist ti 1/--77 TOWN OF YARMOUTH X(1/1:-/-17" SEWAGE PLAN REVIEW CHECKLIST f4/4i� 2--) �4e___,7 Location: A.M. /0c. Lot 'R'rZone of Contribution: In -- Acreager / Commercial: Residential: L________,Street: ) TI.:,' i'''' Village: & Floor Plan: V #Bedrooms: a4 Owners "Zee Installer: / 4*.j4Irt Address: Phone: i - 9 Z Phone: Builder: 7.- Engineer: Lo Address: Phone: W. le' l -;c--- �� Phone: ,Pc eke 17 N/A YES 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years /' 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,.........„- 5. ®vim5. Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 1--,/' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: *------ 9. ..i9.Leaching minimum 100 ft from wetlands Var.: c�-->' 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: c---/ 11.Tank/leaching minimum 10 ft from property line Var.: L...:_.--- 12. _--12. System meets all other setback requirements Var.: L_____- 13.Uses adjustment for maximum high groundwater Var.: \---' 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: .k....------- 15. ✓15. System not in top or subsoil(A,B horizons)or 5'removal t= 16.Proposed contours are suitable .4c/ 17. System meets slope requirements-min. 1/8", 1/4"preferred 1.-.-- 18. System meets breakout requirements PVC liner: Wall: \._...--- 19. �19. Specified tee sizes are proper, gas baffle on outlet tee L._ 20. Sewage is under 10,000 gpd for parcel -_._�- 21.No garbage disposal �� 22. System adequately sized for its intended use L____ 23.Minimum 6"stone or compacted below tank and dbox �-.. 24.Manhole covers within 6"of grade,pump chamber cover to grade ----- 25. /25. Inspection port on plastic chambers/leach field .____.-- 26. �26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size - 28. Septic tank/pump chamber to be factory waterproofed �_--- 29.Vent provided if leaching below 3 feet,under driveway/parking ‘..___....--- 30. �30. Buoyancy calculations for tank/pump chamber _ 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature �_ 35.Foundation footing min. 2 feet above adjusted ground water for new house ___-� 36.Deed Restriction required max. #bedrooms: max. flow: gpd ' -- -__- 37.Check area lots for groundwater/Label groundwater in Assessor's Map �i,r� Plan reviewed by: '_ 6/03/03