�4e___,7
Location: A.M. /0c. Lot 'R'rZone of Contribution: In -- Acreager
/ Commercial: Residential: L________,Street:
) TI.:,' i''''
Village: & Floor Plan: V #Bedrooms:
a4
Owners "Zee Installer: /
4*.j4Irt
Address: Phone: i - 9 Z
Phone:
Builder: 7.- Engineer: Lo
Address: Phone: W. le' l -;c---
��
Phone: ,Pc eke 17
N/A YES
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years /'
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,.........„-
5.
®vim5. Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: 1--,/'
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: *------
9.
..i9.Leaching minimum 100 ft from wetlands Var.: c�-->'
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: c---/
11.Tank/leaching minimum 10 ft from property line Var.: L...:_.---
12.
_--12. System meets all other setback requirements Var.: L_____-
13.Uses adjustment for maximum high groundwater Var.: \---'
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: .k....-------
15.
✓15. System not in top or subsoil(A,B horizons)or 5'removal t=
16.Proposed contours are suitable .4c/
17. System meets slope requirements-min. 1/8", 1/4"preferred 1.-.--
18. System meets breakout requirements PVC liner: Wall: \._...---
19.
�19. Specified tee sizes are proper, gas baffle on outlet tee L._
20. Sewage is under 10,000 gpd for parcel -_._�-
21.No garbage disposal ��
22. System adequately sized for its intended use L____
23.Minimum 6"stone or compacted below tank and dbox �-..
24.Manhole covers within 6"of grade,pump chamber cover to grade -----
25.
/25. Inspection port on plastic chambers/leach field .____.--
26.
�26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size -
28. Septic tank/pump chamber to be factory waterproofed �_---
29.Vent provided if leaching below 3 feet,under driveway/parking
‘..___....---
30.
�30. Buoyancy calculations for tank/pump chamber _
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature �_
35.Foundation footing min. 2 feet above adjusted ground water for new house ___-�
36.Deed Restriction required max. #bedrooms: max. flow: gpd ' -- -__-
37.Check area lots for groundwater/Label groundwater in Assessor's Map
�i,r�
Plan reviewed by: '_ 6/03/03