Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH /e),,61; SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /O S Lot Zone of Contribution: Ig.Q Out Acreage Q� ./9//-6Z-&--3 Commercial: `` Residential {) Street: �!%epluit f / Village: (,(f (fT Floor Plan: C/ #Bedroomsf--5 Owner: Installer: 4 60.47-,A.Lf&Address: Phone: -77 /5 Phone: Builder: • Engineer: 4p r// GG C��/ Address: Phone: L /'w9>---2- Phone: N/A YES NO 1.Required#of copies received ' 2. Date of soils exam and percolation test not older than 2 years (....------- 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,___---- • 5. Water line 10 ft from septic components Var.: (....------ 6. ,/6.Benchmark indicated and shown-NGVD if near wetlands i..------ 1 7. Septic tank minimum 10 ft from foundation, deck Var.: L.--/ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l ' 9.Leaching minimum 100 ft from wetlands Var.: c-/"."' 10.Leaching minimum 150 ft from drinkingwell/25 ft irrigation well Var.: i/ 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: ‘....----- 13. ./13. Uses adjustment for maximum high groundwater Var.: �./ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: c__.-) 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposedcontours are suitable f1817. System meets slope requirements-min. 1/8", 'A"preferred L.-------- 18. . System meets breakout requirements PVC liner: Wall: L------- 19. Specified tee sizes are proper,gas baffle on outlet tee i 20. Sewage is under 10,000 gpd for parcel l 21.No garbage disposal `� - 22.System adequately sized for its intended use (__-----"- 23.Minimum 6"stone or compacted below tank and dbox \----"" 24.Manhole covers within 6"of grade,pump chamber cover to grade �/ 25.Inspection port on plastic chambers/leach field ��r-- 26.Electrical permit for pump chamber/Separate meter for duplexes _..----' 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size __---• 28. Septic tank/pump chamber to be factory waterproofed �.--- 29. Vent provided if leaching below 3 feet, under driveway/parking -/ 30. Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: -----... 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ‘.....------ 33. H-20 loading is subject to vehicular traffic, groundwater ./ _34. Title V Application and permit fee,installer signature _ ' 35.Foundation footing min. 2 feet above adjusted ground water for new house <•� 36. Deed Restriction required max. #bedrooms: max flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Ma Plan reviewed by: e& 6/03/03