Loading...
HomeMy WebLinkAboutReview Checklist 1111/O 'or-( TOWN OF YARMOUTH 1 SEWAGE PLAN REVIEW CHECKLIST " Location: A.M. l.),7 Lot --72.-- Zone of Contribution: In Out `- creage /--Cetti Commercial: Residential: v, Street: Village: 1 Floor Plan: #Bedrooms: Owner: /, I /': ���1 �Ld���e� Installer: �����-�C� Address: Phone: ceP,3 - Phone: Builder: Engineer: ' / pE /, Address: Phone: �l • �„ 3_ , Phone: / --/('./, 2k c N/A YES NO 1.Required#of copies received s-" 2.Date of soils exam and percolation test not older than 2 years L.-- 3.4 _-.3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L__----- 5.Water line 10 ft from septic components Var.: ‘...-- 6.Benchmark indicated and shown-NGVD if near wetlands l__..--- 7. Septic tank minimum 10 ft from foundation, deck Var.: t„.:...---- 8. .8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t.. ----'1 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -,... 11.Tank/leaching minimum 10 ft from property line Var.: LL 12. System meets all other setback requirements Var.: Lam/ 13.Uses adjustment for maximum high groundwater Var.: c _ 14.Leaching set 4-5 ft above adj. water or bottom 91..tet hole Var.: L---" 15. System not in top or subsoil(A,B horizons) o 5' remova (.....----- 16. - 16.Proposed contours are suitable r.--_ . 17. System meets slope requirements-min. 1/8", '/4"preferred (..--- 18. System meets breakout requirements PVC liner: Wall: 4.._-- 19. Specified tee sizes are proper, gas baffle on outlet tee c.....__-- 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use ..---- 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade, pump chamber cover to grade \-_-• 25.Inspection port on plastic chambers/leach field ‘...._____ 26.Electrical permit for pump chamber/Separate meter for duplexes -,---- 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed . -- 29.Vent provided if leaching below 3 feet, under driveway/parking _= 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ------_ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _ ------ 33.H-20 loading is subject to vehicular traffic,groundwater c---- 34.Title V Application and permit fee, installer signature ----, 35.Foundation footing min. 2 feet above adjusted ground water for new house _ , c„_✓- 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6 6/03/03