HomeMy WebLinkAboutReview Checklist 7.0 -,e - 7g-IGi TOWN OF YARMOUTH a--• SEWAGE PLAN REVIEW CHECKLIST '9 ,1 Location: A.M. �4 Lot 7� Zone of Contribution: In - Acreage ����F / 67,, .,„.„,/4„-„,,,, Commercial: Residential ‘.i ® Street: / Village: (��i Floor Plan: ✓ #Bedrooms: 3 Owner: A41,4 Ade' Installer: /b 4.," Address: Phone: P- - -- - 0 s-- -o Phone: 41/47.--//idege,--_,Builder: Engineer: �j Address: Phone: 9� 1f _5a¢-- ig Phone: N/A YES NO 1.Required#of copies received L.------ 2. 02. Date of soils exam and percolation test not older than 2 years (.----'- 3. 4-5 ft of naturally occurring pervious material, above water table L--` 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ��----- 5. Water line 10 ft from septic components Var.: L®. 6.Benchmark indicated and shown-NGVD if near wetlands L_... _ 7. Septic tank minimum 10 ft from foundation, deck Var.: L.--- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L� 9. Leaching minimum 100 ft from wetlands Var.: L__.- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: e.---- 11. /11. Tank/leaching minimum 10 ft from property line Var.: L_.--. 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: - 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L® 15. System not in top or subsoil(A,B horizons)or 5' removal (..--- 16.Proposed contours are suitable C---- 17. v17. System meets slope requirements-min. 1/8", 1/4'preferred (...--- 18. System meets breakout requirements PVC liner: Wall: L,,,- 19. Specified tee sizes are proper, gas baffle on outlet tee (....---- 20. Sewage is under 10,000 gpd for parcel c___.--- 21.No garbage disposal ...____. - 22. System adequately sized for its intended use %-__--- 23.Minimum 6"stone or compacted below tank and dbox (......---- 24. 124.Manhole covers within 6"of grade,pump chamber cover to grade k..----' 25. Inspection port on plastic chambers/leach field L_---. 26. Electrical permit for pump chamber/Separate meter for duplexes c....----- 27.Pump system-2" line,weep hole,check valve, tee in dbox, pump size ._.---- 28. Septic tank/pump chamber to be factory waterproofed -------- 29. Vent provided if leaching below 3 feet, under driveway/parking ..------- 30. Buoyancy calculations for tank/pump chamber /' 31. Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature --------' 33.H-20 loading is subject to vehicular traffic, groundwater ..----- 34. Title V Application and permit fee, installer signature ,®--- 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd ----- 37. 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6.- 1 6/03/03