HomeMy WebLinkAboutEngineered Plan - 2019NKEY: EXISTING CONTOUR: - - - - 4 PROPOSED CONTOUR: •--------... Y OLD TOWN HOUSE RD EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: UTILITY POLE: -O- FENCE LINE: HYDRANT: RETAINING WALL: '<k NCE PVE �'P CONSTA �8'> °rn I Nj -LOCUSJI LOCATION MAP LOT 145 (9,400 SF) ASSESSORS MAP: 86 PARCEL: 78 PLAN BOOK: 220, PAGE: 149 25.0' bo CV ............. LEACH AREA DETAIL CONSTANCE AVE ...----- Edge� eme� --777-7777 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25'+ 12.8') x 2 x 2 = 151 SF (0.74) =_112 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GALIDAY CAPACITY = 349 GAL/DAY F _ N 8294 00' 99 100-- .- �� �, _ 24 cher 30" tree DRIVE i 10111' W i BENCHMARK AT -� RIGHT CORNER OF BULKHEAD ELEVATION = 102.02 X 101.6 EXISTING DWE RNG top Ind.= 1()2.58 bb r IA�� DECK -J� Lf --r CP i LIP i S y4.�� „ 82°2226 W GARAGE 6" tree 101 N 1�z oW o� m th-1 12" tree m �3 cluster C' 102 o � I 102 100 SEPTIC SYSTEM SECTION FIRST FLOOR COVERS WITHIN 6" IE 02.58 OF FINISHED GRADE OP OF OUNDATION "`' R oFINIS RAD m >S�`-�-Vic---��'1/4" per It 1/4" per It COVER22 58 (1' MIN)ELEV.1/4" per ftELEV.gg,43 ELEV. ( ELEV. D -BOX ELEV. 1500 GAL MECHANICALLY COMPACOTED) ((gg SEPTIC TANK MECHANICCALLY COMPACTED) 98.17 ELEV, TEE SIZES: GAS BAFFLE INLET: 6" UP, 13" DOWN AT OUTLET TEE OUTLET: 6" UP, 14" DOWN BED ROOM BED ROOM LIVING A HORIZON ROOM LOAMY SAND 24" GARAGE 0.0 BED ROOM BATH LOAMY SAND 42" ROOM 98.5 C1 HORIZON VERY 111-8-1- INESAND54" PERC AT 51" 54-- KITCHEN 97.5 bh FINE SAND 144"1 2.5Y 7/2 DECK NO GROUND WATER ENCOUNTERED EXISTING FLOOR PLAN ' Y APR 17 2019 HEALTH DEPT. Yurnouth Her -I i Departme3t TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 3-21-19 PERCOLATION RATE: < 5 MIN/IN 2" PEASTONE OR FILTER FABRIC - 3/4" -1 1/2" DOUBLE WASHED STONE INSPECTION PORT ELEV.= 99.0 6s 11° ° ° ° • ' ° ° ° ° ° ° °1*1 96.17 4 4 ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 102.0 ELEV 18" FILL A HORIZON LOAMY SAND 24" 10YR 4/3 0.0 B HORIZON LOAMY SAND 42" 10YR 5/8 98.5 C1 HORIZON VERY 111-8-1- INESAND54" PERC AT 51" 54-- 2.5Y 6/4 97.5 C2 HORIZON FINE SAND 144"1 2.5Y 7/2 90.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40.4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOL AND LEACH PIT ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. THOIIAs J. v Pto•2$471 THOMAS J. SITE PLAN LOCATION: 105 CONSTANCE AVE., YARMOUTH, MA PREPARED FOR: DEBORAH POOLE DATE: 3-22-19 SCALE: 1" = 20'