HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: AM /4'b LOT T/ Date of Subdivision Ap.royal A he /I Street //Z .2, ---6/ Zone of Contribution: I Out Village \r/2 � Commercial ' Residential Owner: �, / V ---S /4.-,i Installer s Builder: Engineer , ',"741A.7 -)/57- 7'.&-." .��l�/',Z N/A YES NO 1. Required number of copies received. 2. Date of soils exam and percolation test not older than 2 years. 3. 4 feet of naturally occurring pervious-material, above water table(new construction) 4. Foundation 2 feet above high point of fronting road for new construction. 5. Water availability letter from Water Department for new construction. 6. Benchmark indicated and shown-NGVD if near wetlands. X 7. Building sewer does not exit center of house. AC 8. Septic tank a minimum of 10 feet from house and deck. 'X 9. Leaching a minimum of 20 feet from house and 10 fee from deck. _ 10. Leaching a minimum of 100 feet from wetlands. 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. 12. S tern meets .11 other etb. k re_uire -nt . " ,.�` Lr .- mac_:. . .( \ 13. Uses adjustment for maximum high groundwater. 14. Leachin• 4 -5 feet above ad'usted wa er table or bottom of test 'it. 15. System not in top or subsoil or 5 foot removal. i h, �6 2<- 16. Proposed contours are suitable. )c 17. System meets slope requirements - min. 1/8". 1/4" preferred. . 18. System meets breakout requirements - peastone elevation carried out 15 feet minimum. x 19. Specified tee sizes are proper. gas baffle on outlet tee. X- 20. Sewage flow under 10.000 gpd for parcel. K 21. No garbage disposal. X 22. System adequately sized for its intended use. 23. Minimum 6" stone or mechanically compacted below the tank and d-box. 24. Manhole covers within 6" of grade - septic tank and pump chamber. 25. Electrical permit for pump chamber. SC 2( 26. Pump system - 2" line. weep hole. check valve, sanitary in d-box. alarm on separate circuit. 27. Septic tank and pump chamber to be Factory waterproofed. 28. Vent provided if leaching below 3 feet or under driveway or parking. 29. Engineer to inspect and certify : a, clay removal X b. wall construction schedule c. commercial system 30. Engineer and Land Surveyor stamp and signature. 31. H2O loading when system subject to vehicular traffic. ' ,--"-- 32. Title V application and fee signed by a licensed installer. X` 33. Foundation tooting 2 feet above adjusted water table. ' 34. Lot subdivided prior to July 31, 1986 - Nitrate Loading. 35. Subdivided prior to April 7, 1989 - Phosphorus Zone 300'. Plan reviewed by: , ��/g/r7 eteh _ . SP//9 7 A-vie „--,,,tj-e. 7-,--').- ,DA-calt_ 4/;;eh 7 ki/1- .m ;tr it,, �4L - Sii .12 viA -` L.fr le Q (rP