Loading...
HomeMy WebLinkAboutEngineered Plans - 2019WEST YARMOUTH TBM = EL. 99.6 � 201.121 GARAGE SLAB 00 - - / JEFFERSON AVENUE LOT 63 � I / r uj D 23,522± S.F. I / (0.54± AC.) P , N POOL -1 C) r p j LOCUS ' 74 WASHINGTON A\ p Ip / ---L_ __�, LOCUS MAP ��`` c LOCUS INFORMATION C\1 �� I , N , �►. PLAN REF: LCP 432742-1 Lc Q I ' (Y)' PARCEL ID: MAP 63 PAR. 74 r---- -J 21 �� 'j i c;(0 O I / I FLOOD ZONE: NOT IN FLOOD ZONE SEPTIC SYSTEM ' °)J = REPAIR PLAN � �z W o / LOCATED AT: OLQ N / � z � _ / � 74 WASHINGTON AVE. 00 WEST YARMOUTH, MA /\ w 1 PREPARED FOR �p 0)—ATTY REBECCA R. CAREY/ �1 — — a- �- aqui -wo-V , CONS. FOR DOROTHEA McGURK — — Q APRIL 10, 2019 iii i-------�,�� LL"'AA, -....- 0 i 70.23' THEODOP\957 P\005EVELT,P\D, GENERAL NOTES: I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALT_ CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE CRUSHED, PUMPED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4- SCH 40 • 1/8 -/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL 93.70 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 18. PLACE 40m1 POLY LINER AROUND ENTIRE LEACHING AT EDGE OF SOIL REMOVAL, FROM ELEVATION 98.40-94.40, TO PREVENT BREAKOUT. 19. PLACE GEO—GRID UNDER LEACHING AS SHOWN Health Department PROVED Date SCALE: 1"=20' LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT OF STEVEN oRUMBA N0.35797 �' U 140 MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 697 T.O.F. EL.=103.10 PROPOSED TANK INSTALL RISERS W/IN 6" OF FINISH GRADE EL100.0± r- EL99.O± A11 EL. 98.20 OSa2X (MIN.) , �• TEES ARE TO BE e . 4• SCH 40 PVC :v Exist. Invert w INV.= 97.15 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS PUMP CHAMBER D -BOX INSTALL RISERS TO w/in 6' OF FINISH GRADE INSTALL RISERS W/IN 6" OF FINISH GRADE 0 Se 1X (MIN.) (-INV.= 96.90 INV.=96.50 EXIST. 1,000 GALLON MONOLITHIC SEPTIC TANK NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) PUMP CHAMBER AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED. 4) GAS BAFFLE W/ FILTER TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITS, ZABEL OR EQUAL INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER. / 1,760 LB. STRENGTH. PC INV.(OUT)=96.25 ALARM ON EL: 94.08 PUMP ON EU 93.58 PUMP OFF EU 93.25 BOTTOM OF INT. P.C. EL 92.25 FEL98.80± F EL98.80± F.G. EL- 99.8± INSTALL SANITARY TEE "EL.97.55±40pVC to• .. - i f oRCE MpdN �La- .27 s FINISH GRADE=99.25 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA L=12'(MAX) 4" SCH 40 PVC 0 S= 1% (MIN.) 3.3" TO INVERT - 4V.=98.20 22' INV.= 98.40j D -BOX - 16" TEE SHALL NOT EXTEND BELOW FLOW LINE 12" (USE DB -5 W/BAFFLE) .M M M jft L INV.=96.25 PROPOSED 1,000 GALLON PUMP CHAMBER SEPTIC SYSTEM PROFILE N.T.S. - PROVIDE WATERTIGHT CONCRETE RISER WITH SECURED COVER TO GRADE NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT -2"BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO. 560 OR EQUAL 2'SCH. 40 DISCHARGE TO D -BOX •2"SCH. 40 TEE w/ CLEAN-OUT CAP PROVIDE 1/4" WEEP HOLE IN DISCHARGE PIPE FOR SELF -DRAINING FORCE MAIN 2" BALL CHECK VALVE SCH. 80 PVC 100 P.S.I. FLOWMATIC MODEL No. 208S PROVIDE 2- WIDE ANGLE FLOATS: 1\ 2" SCH. 40 PVC DISCHARGE PIPE FLOAT NOA: PUMP ON/OFF (BARNES 073618 OR EQUAL) FLOAT NO.2: ALARM ACTIVATION (BARNES 073612 OR EQUAL) BARNES SEV412 PUMP .5 H.P. 115 V 2" DISCHARGE PASSING 2" SOLIDS VOR EQUAL NOTE: SEPTIC TANK AND PUMP CHAMBER TO BE FACTORY WATERPROOFED AND SEALED WITH THOROSEAL OR EQUAL PUMP & ACCESSORIES AVAILABLE AS A UNIT THROUGH WIGGEN PRECAST CORP., BOURNE MA. (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WILLIAMSON ELECTRIC (781) 444-6800 PUMP DETAIL N.T.S. BUOYANCY CALCULATIONS 1.000 PUMP CHAMBER ILPI t: 8.5' x 5' x 4 x 62.4 = 10608 lbs ground cover: 8.5' x 5' x .75 x 120 = 3,825 lbs empty tank: 8,000 lbs groundcover + empV tank > uplift: 3,825 + 8,000 = 11,825 lbs > 10,608 lbs TANK BUOYANCY CHECK O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 8 CYCLES/DAY (SAND) 330 - 4 = 82.5 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE - 250 GAL/FT = 0.33 FT/CYCLE (4") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV. EL: 96.25 - ALARM ON EL: 94.08 =2.17' STORAGE PROVIDED = 2.17' X 250 GAL/FT = 542.0 GALLONS INV.ELEV.=97.99 MIN. COVER OVER S.A.S. = 9" TWO INSPECTION PORTS(MIN.) OF FINISH GRADE 4 ROWS OF 6 UNITS AT 4.0'/UNIT = 24.0'/ROW SOIL ABSORPTION SYSTEM (PROFILE) �,IVILrtrt BREAKOUT=TOP ELEV.=-98.38 No. 1140 "' INV. ELEV.= 97.99 .iPEnirrc BOTTOM ELEV.= 97.70 NI R RESTORE VEGETATIVE COVER poly liner (see note 18) PAGE PERC SAND EXISTING SUITABLE MATERIAL 5' MIN. ABOVE BOTTOM OF 11 1D 1� T.P. 5X08' PROVIDED G'W' EFFECTIVE WIDTH = 4 x 2.83' = 11.32' ( ) USE 4 ROWS OF 4 INFILTRATOR QUICK 4 PLUS ADJ. GROUNDWATER EL.=92.62 - STD LP (3.3" INVERT) UNITS -NO STONE SOIL LOG DATE: MARCH 14, 2019 SOIL EVALUATOR: DARREN M. MEYER, R.S., WITNESS: A. VONHONE, YARMOUTH Elev. TP -1 Depth 97.20 0" FILL 95.70 18" A LOAMY SAND 1OYR 4/1 94.37 B 34" LOAMY SAND 7.5YR 3/4 93.70 42" C MEDIUM - COARSE SAND 5.OYR 3/4 89.04 98" PERC RATE <2 MIN/IN. ("C" HORIZON) GROUNDWATER OBSERVED AT 55' EL 92.62 WELL;- AIW-230, ZONE D. LEVEL 19.8, ADJ 0.0' USE OBSERVED GROUNDWATER ELEVATION PLACE GEOGRID UNDER LEACHING, EXTENDING 1 FOOT PAST PERIMETER TYPICAL SECTION KTA DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) SEPTIC TANK/PUMP CHAMBER: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G W/NEW 1,000G PUMP CHAMBER LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 4 ROWS OF 6 - INFILTRATOR QUICK _4 STD LP (3.3"_ INVERT) UNITS WITH NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 74 WASHINGTON AVENUE Prepared for: Atty Rebecca Carey, Design and Site Plan by: MEYER & SONS, INC. PO BOX 981 EAST SANDWICH, MA 02537 508-362-2922 W. YARMOUTH, MA Cons for Dorothea McGurk SCALE DRAWN DATE N.T.S. DMM 04/10/19 REV. DATE SHEET NO. 2 of 2