HomeMy WebLinkAboutEngineered Plan - 2019ASSESSORS MAP: 4-7__
-- - ---- - - - - - TEST HOLE LOGS 1) The installation shall comply with the State Environmental Code Title V and Town of
PARCEL- Board of Health Regulations. I
FLOOD ZONE: G D% SOIL EVALUATOR:� yl , �° 2) The septic system as proposed on this plan shall not be installed until a licensed town installer
_
WITNESS: !?'� 104&
►receives approval and an installation permit from the applicable town.
REFERENCE: �',p� 13a' -I) DATE: L ( 3) Prior to installation; the installer shall verify the location of utilities, sewer inverts, sewer lines
O L Z �l i,...I; :% 14•. , and existing septic components prior to installation.
PERCOLATION LATION 1 A E :
y, ! 4) All gravity sewer piping is to be 4 inch schedule 40 PVC at 1/8" per foot. l he first 2 feet out of
MTED< < 1QC�� TH- I TH-2 the distribution box shall be level. All piping connections to be glued.
-- ------ -- - - -- .._ __ p p g
5) This septic design plan is not to be utilized for property line determination or for any other
LOCATION MAP
'I
�iN.M
�}# �tOttf j^ purpose other than the proposed septic system installation.
toirmt�I 9 6) All Title V components are to meet Title V specifications. ;
7) Parking shall be prohibited over Title V components unless components are H2O loaded.
8) The existing leaching or cesspools shall be pumped and filled with material per Title V
l abandonment procedures. Leaching and cesspool(s) and contaminated soils within the
proposed SAS shall be removed and replaced with clean sand per Title V specifications.
9) Septic components are to be 10' from a water service line. Sewer lines crossing a water line shall
1 be sleeved with an appropriately sized schedule 40 PVC with ends grouted. The water service
1
line or the septic line can be sleeved with the sleeve being a distance of 10' on both sides of
crossing the line.
\P I 10) If a garbage grinder exists in the structure, it is to be removed if the septic system is not
- designed to accommodate a garbage grinder.
11) The installer is responsible for care of excavation around all utilities on the property and
SEPT IC SYSTEM' D E S i GN protecting the structural integrity of all structures during the installation process of the septic
isystem.
FLOW ESTI MATE 12) This plan only represents that a septic system can be installed on the property meeting Title V
requirements.
BEDROOMS ,AT GAL/DAY/BEDROOM - ? GAL/DAY i 13) The property owner shall review design criteria to approve the total nurnber.of bedrooms and
design flow. Installation of the septic system as proposed and receipt of payment for the design
SEPTIC TANK ? shall be deemed approval of the design criteria by the property owner or agent of.
J CAL/DAY ,',x 2;. DAYS. - � GAL
14) The validity of this plan shall expire with the expiration of the town installation permit issued for
, this plan or the validity of this plan shall expire on the expiration of the Certificate of Compliance
USE GALLON SEPTIC TANK 1 issued for the installation of the proposed system on this plan.
rt ,SS��A107SYSTEM
SIDE AREA:-j.-i-��.,'��' X
UOTTOM AREA f �� ' X O 1 'Z�j�,�2
DAID
SEPTIC SYSTEM SECTION
17, ,
_ LVA .p iy
GAL
SEPTIC TANK
MAS,v u#
a N0.1Q6o^^ �€
v"
A_ A)
W Q5,; 04 r,D
)�araoath Health U12par-tment
SPR D
/4,
Nam
a3ate
DATE HEALTH AGENT
.i