HomeMy WebLinkAboutEngineered Plan - 2019ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 19.8' MINIMUM .75' OF COVER OVER PRECAST SYSTEM PROFILE (NOT TO SCALE) PRECAST H-10 RISERS (TYP.) 2'0 17,42' 4"OSCH40 PVC PIPES LEVEL 1ST 2' 10" EXISTING 14" TEE SEPTIC TANK** TEE f 16.25'* , \ 000000000o00 GAS BAFFLE ::; +°000000°0° 16.12' 15.95' WATERTEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE SLOP (--L-% SLOPE) (-1-7. SLOPE) FOUNDATION- EXIST. SEPTIC TANK 13' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEND- 99- EGEND 99- EXISTING CONTOUR X 99 1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2Y� SLOPE OF GROUND C-0 UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS i ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 4/3/19 PERC. RATE _ < 5 MIN/INCH CLASS I SOILS ELEV. PROVIDE 40' OF 40 MIL 'Q LINER AT 5' OFF SAS IN 0" 16,5AREA SHOWN. TOP AT ELEV. 16 2' SOTTOMA T E 1 2 2'f A LS 5" 1OYR 3/2 B LS 10" 10YR 5/6 15.7' CLEAN T5 FILL 60„ 2.5Y 7/4 11.5' C SIEVE FS 2.5Y 6/3 . L. . GROUNDWATER ADJ. DATA: WELL: AIW 247 ZONE: C ADJUSTMENT: 2.3' (MARCH) 120" ' I 6.5' GROUNDWATER ENCOUNTERED AT 81 " EL. 9.75 DCL' #19-079 15' 0 10 20 30 4• 50 FEET 21 HIGH CAPACITY INFILTRATORS EACH UNIT: 6.25' X 2.83 X 16" HIGH OVERALL DIMENSIONS TO OUTSIDE OF UNITS: SEE DETAIL (NO STONE PROPOSED) 4.0' LEACHING FACILITY ADJUSTED GROUNDW TER EL. 10.9' O 25.0' LEACHING DETAIL 1"=10' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q - 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND Follins o Pond��'�<r OGS l Diff oo, Eii/rs P fh Stoney Hill R 0 z 0 a Q Locus 03r,af lyesfer� Knob Hill Ro Whites Path glu eo on ' o LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1 "=2000'± WORK. 11. ANY UNSUITABLE MATERIAL. ENCOUNTERED SHALL ASSESSORS MAP 109 PARCEL 20 BE REMOVED BENEATH AND 5' AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE X PROPOSED LEACHING FACILITY. (AREA OF MINIMAL FLOOD HAZARD) AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITYPANEL #25001C0579J AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATED 7/16/2014 BASEMENT LAUNDRY BATH BEDROOM STORAGE DEN 1ST FLOOR DINING ROOM BEDROOM[ KITCHEN BEDROOM IBAIHROOMI LIVING ROOM 2ND FLOOR BATHROOM - OPEN BEDROOM FLOOR PLAN NOT TO SCALE Permit Vali(i for REPoIR ()M SF:I'ric sYs1F,IVr ONLY., dur'"to' state .and Vocal septic variaures. Board of Health review and .ipproval is required for any, future,to Sewage fat rlities an l/or st ucim eshls.t•lling. i arinouth He.tllll f>rp:trtnrcnt I Name. )ate _141GTS a q` a s�� OF, DANIEI_A. CyG sFU�> Dr1NilEL F'\ AwAoal OJALA':' A. 0 el" CIVIL OJ.ALA o.465 2 o No. 40980 =�\P�cAGroTc FiOaIV�,�• Lw. /.�=t`G�' SC./^' >/ ENS ,F, v;.. -usc� � Jai y Sf DATE DANIEL A. OJALA, P. E., P.L.S. SITE IS LOCATED WITHIN A STATE ZONE II VARIANCES REQUESTED:' UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1h): REDUCTION IN GROUNDWATER ADJUSTMENT FROM 2.3' TO 1.15' SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 RE -USE EXISTING SEPTIC TANK** LEACHING: 4.73. SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 440 GPD/0.74 GPD/SF = 595 SF LEACHING REQ'D 595 SF/29.5 SF/UNIT = 20.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (21) HIGH CAPACITY UNITS IN FIELD CONFIGURATION SHOWN 21 UNITS x 29.5 SF = 619 SF>595SF 619 SF (0.74) = 458 GPD (OK). MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #59 NORTH DENNIS ROAD SOUTH YARMOUTH, MA PREPARED FOR MICHAEL MALLOR DATE: APRIL 17, 2019 off 1508-362-4541 I fax 508-362-9880 downcape.com dOWn COP en ffifteeriftg, iac. civil engineers Ian d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 19-079 BASE.DWG