Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2019TSR ROW Qv 37 --' �•S 0 80.82 6 Off, I' 1 �i 38.3 LOT 36 ' 1 AREA = 0.24 acres ' 1 Lu I I U 1 1 WI N QI 1 39.4 7a 1 W 39.0 paved IN '► cp *AGE SLAB driveway ° N 38.8 TBM = EL. 39.5 CONCRETE PATIO 38.4 SCALE: 1 "=20' TpF @f 40.0 AO ml 39.4 ! J poly yarr�er 3— B 39.5 15 _ �► tree �+! O O LEGEND I SOUTH YARMOUTH �-/ PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT yOF MASSACyGN"� N 0 BOJ �4 L--�ZO' 11W 000 TP -1 t--16.54, 0 38.7 to 1 38.9 `t " PROP. 1,500G SEPTIC TANK 105.0a Permit valid for REPAIR OI' SEP'1'I(' SYS"I VNI BED ONLY, dice to_ o State and Local septic variances. RM FG� Board of Health review and approval is required, for LIV GA " any l'ufure additions/reniwatioas/alterations to RM sewage facilities anillor structures/dwelling. BATH Yarmouth Health Department KIT DIN APPROVED/ BED RM RM ePTn� FLOOR PLAN Mme bate OLD TOWNHOUSE ROAD r v ROW.... LOCUS LOCUS MAP LOCUS INFORMATION TITLE REF: 13117/222 PARCEL ID: MAP 077 PAR. 068 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE PROPERTY IS IN NITROGEN SENSETIVE AREA SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 137 QUARTERMASTER ROW SOUTH YARMOUTH, MA PREPARED FOR RAY CAMPBELL MARCH 22, 2019 REV: APRIL 3, 2019 OF �ss9 DARREN NMR y MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 J#1894 ELEV. TOP DROP FND. (Existing) = 40.0 - IB INV. 37.50 INV. 37.17 G.EL: 39.3 INV. 36. NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE F.G.EL: 39.20 F.G. EL: 39.20 I I h.G.tL• S/.3U 6� 10" I TEE'S ARE TO BE 4" SCH 40 PVC FINISHED GRADE (39.2) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 14" 6 ® S= 1% (MIN.) INV. 35.75 INV.36.0 2' EFF. DEPTH INV. 35.55 GAS PROPOSED DB -3 BAFFLE DISTRIBUTION BOX (H20) INV. ELEV.= 35.45 - PROPOSED 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (B): 1) A 5 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 15 FT (MAX) FROM DWELLING VS REQ'D 20 FT. (LINER PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED) 16. PLACE 40 ml POLY BARRIER AS SHOWN, FROM EL 36.45 - 32.45 TO PREVENT INFILTRATION INTO BASEMENT. OF MAss9 /' �y DARR N E N 1 40 51 ° MNITAR\1`� -' SEPTIC SYSTEM PROFILE !y 0000• 0 0000 ®®®®®®®®®®® ®®®®®®®®®®® ®®®®®®®®®®® 2 X 8.5' 3/4" - 1-1/2" DOUBLE WASHED STONE !y / EFFECTIVE LENGTH = 25' 1 TOP CONC. ELEV.= 36.45 INV. ELEV.= 35.45_ BOTTOM EL.= 33.45 SEPARATION 5.25FT. BREAKOUT ELEV.= 36.45 ® 00 0 0 000 0000®®® 000000® 4' 1 5 FT. 1 4' I EFFECTIVE WIDTH = 13.0' 1 BOTTOM OF TESTHOLE EL: 28.20-4- SOIL ABSORPTION SYSTEM (SECTION) SOIL LOGS DATE: FEBRUARY 20, 2019 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT. Elev. TP- 1 Depth 39.20 0" FILL 38.28 11" A LOAMY SAND 10YR 4/1 37.87 16" B LOAMY SAND 10YR 6/6 36.38 34" PERC TEST C MEDIUM/ O EL 34.70 COARSE SAND 2.5Y 6/6 28.20 132" PERC RATE <2 MIN/IN. ('C" HORIZON) NO GROUNDWATER OBSERVED s I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. (500 GALLON LEACH CHAMBER) DESIGN CRITERIA **PROPERTY IN ZONE II, DEED REST. REQ'D** NUMBER OF BEDROOMS: 2 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd, USE PROP. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (220)/0.74 = 297.29 S.F. USE ONE (1) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON SIDES & ENDS: 16.5' L x 13' W x 2'D BOTTOM AREA: 16.5 x 13 = 214.50 SF SIDE AREA: (16.5 + 13) X 2 X 2 = 118 SF TOTAL SQUARE FEET PROVIDED = 332 vs. 298 REQ'D DESIGN FLOW PROVIDED: 0.74(332 S.F.) = 246 G.P.D. vs. 220 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 137 QUARTERMASTER ROW, S. YARMOUTH, MA Prepared for: Cam bell Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 03/22/19 PO BOX 981 REV DATE EAST SANDWICH, MA 02537 CHECKED SHEET NO. 508-362-2922 04/03/19 DMM 1 2 of 2