HomeMy WebLinkAboutEngineered Plan - 2018KEY: EXISTING CONTOUR: ---- SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION ROUTE 6 PROPOSED CONTOUR: •---•••••... EXISTING SPOT ELEVATION: 25.5 2" PEASTONE OR FILTER FABRIC FLOW ESTIMATE: FIRST FLOOR COVERS WITHIN 6" 3/4" - 1 1/2" DOUBLE .QoFsFy� BLUE ROCK RD PROPOSED SPOT ELEVATION: 25.5 105.25 O 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY OF FINISHED GRADE WASHED STONE 9GAI TEST HOLE: FOUOF NDATION ti UTILITY POLE: -O- �-+Lm�v,+ INSPECTION PORT ELEV FENCE LINE: SEPTIC TANK: FINISHED G �v RADE ELEV.= 102.33 ►- HYDRANT: -b- 330 GAL /DAY x 2 DAYS = 660 GAL 1 /8" ear ft 3 MAX. " " >++ . a •; ++ + N RETAINING WALL: 0 101.42 „ COVER ? USE 1500 GALLON SEPTIC TANK � 1/8 per ft 1 MIN m (EXIST NG) a 101.91 1/8" per ft ) Z LOCUS LEACHING AREA: ELEV. L C 101.7 101.53 34.5' USE 5 -125 GALLON CHAMBERS (6,V x Tx 12" EFF. DEPTH) WITH 102.16 ELEV, ELEV ° ° ° ° ° ° 100.5 LOCATION MAP ELEV. D -BOX LOT 2 (29,156 SF) 4' OF STONE AROUND SIDES AND 2' AT ENDS (34.5' x I Tx 12" DEEP) (6 OF STONE UNDER OR 2 4 2.4 ELEV, ASSESSORS MAP: 100 PARCEL: 26 0 .I TTTT� 1500 GAL MECHANICALLY COMPACTED) 34.5' x 11' PLAN BOOK: 202, PAGE: 99 ^i SIDE AREA: (34.5' + 11') x 2 x 1 = 91 SF (0.74) = 67 GAL/DAY RAI` E: EXISTING OUTLET SEPTIC TANK PIPE 11", TOELEV.-102.32" OF STONE UNDER OR 1 5 -125 GALLON CHAMBERS (ACME LC -6) q, j LEACH AREA DETAIL BOTTOM AREA: 34.5' x 11' = 379 SF (0.74) = 280 GAL/DAY ECHANICALLY COMPACTED) ELEV. W2 AT EONFDS 0(34.5x 11 AROUND DEEP) D TEE SIZES. CAPACITY = 347 GAL/DAY INLET: 6" S. 13" DOWN GAS BAFFLE OUTLET: 6" UP, 14" DOWN AT OUTLET TEE ADJUSTED GROUND WATER ELEVATION = 96.5 N REQUIRED VARIANCE FROM TITLE FIVE: � �-✓J LEACH AREA TO BE LESS THAN V ABOVE GROUND WATER (VARIANCE OF 1.0'), TEST HOLE LOGS TH-1 104.5 ELEV. 1. SECTION 15.212: DECK 0/A HORIZON Permit valid for REPAIR- OF' SEPTIC SVSTFm SH DECK bh ENGINEER: THOMAS McLELLAN, P.E. LOAMY SAND 10YR 4/3 ONLY, dire to State and Local septic variances. MUD KITCHENBATH BED WITNESS: AMY VON HONE R.S. 9„ 103.8 Board of Flealth review and approval is required for ROOM DINING ROOM B HORIZON LOAMY SAND any fufurc adilitionslreno� ations/alterations to BATH DATE: 12--13-18 34" 10YR 5/8 sewage facilities and/or structures/dwelling. LIVING PERCOLATION RATE: < 2 MIN/IN 101.7 Yarmouth llealth Departin nt ROOM BED BED ROOM ROOM C HORIZON MEDIUM SAND 2.5Y 7/4 1.USGS AP.� ICIV D GROUND WATER ADJUSTMENT: WELL: A1W-247, ZONE: B, ADJ. (NOV.): 2.7' 120" OBSERVED 94.5 garage orc USE ZADJUSTMENT PER BOH -AjADJUSTED wd% GROUNDWATER ELEV.= 96.5 GROUND WATER / 7- J E 109"® Sto' 06 105 108 107 C 109 �,' 1 r� �,� p� ST Ole 108 t J ►��'' \ J pa t% h Shed ` fire pit mIn 107 pE (104.6 �I th-1 BENCHMARK AT RIGHT CORNER OF BULKHEAD ELEVATION = 101,20 104 102 ONW. 101 h � �� � o z N w� /;jm- 102 f- LL1MQ�Q 10315( � Q 104 GARAGE ��•.,� , UR��E \` . N 7g 556833;, W 106 Stockade ^�_, _/ �I -Fence 20" oak a 105--.--,' _ 105 , 4 rn 106 EXISTING FLOOR PLAN tiS11Ut-MASS q .� TERRY ANN WARNER � No. 33721 is I . n -la 100E=P APR 2 4 2019 HEALTH DEPT. NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE -TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13, EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. PROPOSED PLUMBING CHANGE, (RAISE BY 11") TO BE CONFIRMED PRIOR TO CONSTRUCTION, Sin JF�?S�, Ti10h4AS J. LIxLELL AN CIVIL . Rc.3a471 1 WINS w M \, --.III THOMAS J. MCLhiA AN, P.E. SITE PLAN LOCATION: 9 ANGELOS RD., S. YARMOUTH, MA PREPARED FOR: JIM MCGOVERN DATE: 12-17-18 SCALE: 1" = 30' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048