HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
' SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /11 Lot 7/ Zone of Contribution: In Out Acreage
Commercial: Residential:
Street: R-6?j �2?�
Village: ^6(� di,6Floor Plan: #Bedrooms:
Owner: ()asr //< v 4.J,c C�Z.P/i Installer: # rrY
Address: Phone: /VS-- 5”3
Phone:
Builder: Engineer: C�Q(� CG
Address: Phone: U 362,7-0 ._
-
Phone: be/7 /6v't' ( l' -e'l r /wP 071(-6 /5 /1417
N/A YES . NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table t/
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: (....------
5.Water line 10 ft from septic components Var.: t..:.------
6.Benchmark indicated and shown-NGVD if near wetlands L./"
7. Septic tank minimum 10 ft from foundation, deck Var.: \--
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: k/
9.Leaching minimum 100 ft from wetlands Var.: L.------
10.
-/10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: \..---•'--
12. System meets all other setback requirements Var.: L/
13.Uses adjustment for maximum high groundwater Var.: \/
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: C,
15. System not in top or subsoil(A,B horizons)or 5'removal l. /,'
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '/a"preferred
18.System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
• 22.System adequately sized for its intended use ?
23.Minimum 6"stone or compacted below tank and dbox Q.-//
24.Manhole covers within 6"of grade,pump chamber cover to grade L/
25.Inspection port on plastic chambers/leach field C
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed :/
29.Vent provided if leaching below 3 feet,under driveway/parking ,-4
30.Buoyancy calculations for tank/pump chamber .
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater -------
34.
134.Title V Application and permit fee,installer signature ._/--
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓ /
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: Cik' ' 6/03iO3