Loading...
HomeMy WebLinkAboutReview Checklist 1 2-'7c TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST 1 Location: A.M. 2,2-- Lot -3 g7 Zone of Contribution: In Out Acreage Commercial: Residential: Street: F.---,/tie i/--.- Village: ` jr Floor Plan: l------- #Bedrooms: -2 ' Owner: ,1/-e. 0>/i° Installer: 7 Address: Phone: Phone: Builder: Engineer: / 01•A--16 Address: Phone: �?1 - ‘ - Phone: 60c - `- e .ice N/A NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �_,.- 5.Water line 10 ft from septic components Var.: -(_ f ,,. 6.Benchmark indicated and shown-NGVD if near wetlands :(....---- 7. .--- 7. Septic tank minimum 10 ft from foundation, deck Var.: \,2,,,f,_--: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 6 - 7 4.-- 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking wel1/25 ft irrigation well Var.: i �,% '} 11. Tank/leaching minimum 10 ft from property line Var.: ' `! c_� 12. System meets all other setback requirements Var.: - 13.Uses adjustment for maximum high groundwater Var.: V--- - 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: -•,-------- 15. ,,r..i15. System not in top or subsoil(A,B horizons)or 5'removal L.-- 16.Proposed contours are suitable L--. - , 17. System meets slope requirements-min. 1/8", ' "preferred ✓✓ 18. System meets breakout requirements PVC liner: Wall: L.-- 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel . 21.No garbage disposal 22. System adequately sized for its intended use L_-- .- 23.Minimum 6"stone or compacted below tank and dbox N----- . 24. ----- 24.Manhole covers within 6"of grade, pump chamber cover to grade `--- 25.Ins ection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed ___ 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: / 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house --.. il 36.Deed Restriction required max. #bedrooms: 2--max. flow: ,'-- "Ctpd Lam- 37.Check area lots for groundwater/Label groundwater in Assessor's Map i,__ Plan reviewed by: J L-4 6/03/03