HomeMy WebLinkAboutReview Checklist 4-/2 -",
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. VIO 4 Lot 6 Zone of Contribution: In Out Acreage
/'p�� Commercial: Residential:
Street /0asc-U �i�JV'(
Village: fr• Floor Plan: #Bedrooms:
Owner: /71l(d V. /G( 7Installer: 6,14
Address: Phone: c-gfr= /AS�.L/��
Phone: 2-,,,,,,440/ y�
e--e- "I
Builder: Engineer: ✓%'✓ ' ,j( f.' e=Gi
Address: Phone: �jj � O-0
,'A' L�1%1 �i
Phone: �u~r i ;if,.-.‘el'icies0.6(4/
I 440X NY` w �
N/A YES NO
1.Required# of copies received ✓
2. Date of soils exam and percolation test not older than 2 years %.,...----
3. 4-5
./3. 4-5 ft of naturally occurring pervious material, above water table t....----'
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: moo'
5. Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands t....r-
7. Septic tank minimum 10 ft from foundation, deck Var.: L---
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t./
9.Leaching minimum 100 ft from wetlands Var.: ....---
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: ? C...--) .-------
12. System meets all other setback requirements Var.: k..----
13. Uses adjustment for maximum high groundwater Var.: L-----
14.
/14.Leaching set 4-5 ft above adj.water or bottom e Var.: t------
15.
115. System not in top or subsoil(A,B horizons) 5' remova
16.Proposed contours are suitable t/
17. System meets slope requirements-min. 1/8", 1/4"preferred t/'
18. System meets breakout requirements PVC liner: Wall: +`/
19. Specified tee sizes are proper, gas baffle on outlet tee tkoll h/ 4.// `/
20. Sewage is under 10,000 gpd for parcel `---•
21.No garbage disposal t. ---'
A
22. System adequately sized for its intended use 11
23.Minimum 6" stone or compacted below tank and dbox L/
24.Manhole covers within 6"of grade,pump chamber cover to grade t/
25.Inspection port on plastic chambers/leach field t...----
26.
r26.Electrical permit for pump chamber/Separate meter for duplexes moi'
27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size S/I .l.-=28. Septic tank/pump chamber to be factory waterproofed p4l4YX.__.
� t..�
29. Vent provided if leaching below 3 feet, under driveway/parking •-..---•
30.Buoyancy calculations for tank/pump chamber •.......---
31.
.�31.Engineer to inspect and certify soils: wall: commercial: `,®--#
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature `..---'
33.H-20 loading is subject to vehicular traffic, groundwater t/
34.Title V Application and permit fee, installer signature - �.--s'
35.Foundation footing min. 2 feet above adjusted ground water for new house c.---'
36.Deed Restriction required max. #bedrooms: 2i max. flow: 'jam gpd t....--'
37.Check area lots for groundwater/Label groundwater in Assessor's Map �...e*'‘
Plan reviewed by: 6/03/03