Loading...
HomeMy WebLinkAboutEngineered Plans - 2019ENTRY --97--EXISTING CONTOURN x 100.98 EXISTING SPOT GRADE LOCUS 97 PROPOSED CONTOUR cm °� KITCHEN DINING LBATHJIBEDROOM / WEXISTING WATER SERVICE G EXISTING GAS SERVICE o�Fr, oporST �oPo OVERHEAD WIRES o /� TEST PIT 090 D Z L A LIVING ROOM BEDROOM BEDROOM _ v]�T�l {b BENCHMARK 99,04 100,46 LEGEND Q Roti ENTRY 101,51 FLOOR PLAN �� 98,29 2$ ` x 101,00 x 102,10 7------ - 0 1.86 20" E LOCUS MAP . e�; e102�r 7 � 103,54 14, f NOT TO SCALE �- — 101198 GENERAL NOTES: LOT 28 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 13,7661 fSF S ON O BOARD OF HEALTH AND THE DESIGN ENGINEER. ° o x 103,31 103, 0 ��� ROP 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS (PAVED: • . .... ff 00, 8 G0 �' `N� `NES OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE v 97,71 ;:D�?lVEWAY' LOCAL RULES AND REGULATIONS. � vFFER F NERD 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 103.69 W 6� 5 d TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE WA PYA X00 S DESIGN ENGINEER. z \// /. �51�E ~ 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING + 03,61 0PP0 FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN 97.78 / / 102,13 �� x 103,49 a ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 103,66 m 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE OWNER102 6� � .: "' NEW TP HEALTHO FOR CPROPOER INSPECT OONS DTURINGH CONOSTRUCBTIION.OAROF 98,18.:. 1029 98,02` 103,41 x 1 3,46 <v � 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. x EXISTING p o 8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. HOUSE(J15) ( N 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS CIO / T. 0. F.104.9 103.24 'V o)' a AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE NN J 02,65 DIRECTED BY THE APPROVING AUTHORITIES. �O. 2 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY r` `! 102.95 103,05 X 1 ,47 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING x M 3 / \ '� CONSTRUCTION. \ 97,48 103, 6 M-1 EX/ST/NG LEACH PIT 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS r 103,0 FILL WITH SAND IF REQ'D IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND / 103,29 x : • ?` • x1 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). x=�70' 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE *102,51 103,31 INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. y 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND BENCHMARK NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. CORNER OF STOOP j216 /• �� MAssq�tiG 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC EL. =103.66 S 6 103,09 + r x/02 3 3�`� SYSTEM COMPONENTS NOT SHOWN ON THE PLAN X36' / o PETER T. EX/STING SEPTIC TANK 40•• F ;D D T �/ �� McENTEE (TO REMAIN) /X TOP OF TANK EL. =102.96:± EXIST/NG S.A.S. ' v No. 35109 MAP ID: 59-14 = 01. 3f TO BE REMAIN `� Ic/sL�� Yarmouth Health Department OLD CESSPOOL x 1 .47 PROPOSED SEPTIC SYSTEM UPGRADE PLAN p VED FILL WITH SAND IF REQ'D ((_ 15 HERVEY LINES LANE, SOUTH YARMOUTH, MA ��0 7 STRIPOUT BOUNDARY 3 15 Prepared for: Cape Cod Septic Services W. Yarmouth MA 02673 P P p , Name Date (TO REMAIN) OWNER OF RECORD Engineering by: SCALE DRAWN JOB. NO. FLECK, JESSE J C/O PROF-2013—S3—LEGAL TITLE TRUST Engineering Works, Inc. 1 "=20' P.T.M. 103-19 60 LIVINGSTON AVE. 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. PLAN REFERENCE: RECORD PLAN BY JOSEPH REGO PE, PLS, REVISED 7/12/01 ST. PAUL, MN 551077 (508) 477-5313 3/5/19 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE - SHALL NOT BE AT, OR BELOW, EL.=100.5 SEPTIC TANK PROPOSED D -BOX FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED INSTALL RISERS & COVERS OVER INLET S.A.S. & INSTALL RISER OUTLET AND SET TO 6" OF FINISH GRADE COVER SET & WATERTIGHT TO 6" OF GRADE PROPOSED S.A.S. /EXISTING INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF SERVE / /HOUSE(1115) T.O.F.=104.92± F.G. TO AS INSPECTION PORT / T.O.F.=104.92 F.G. EL=103.8±F.G. EL.=103.0± F.G. EL.=103.31 � F.G. EL.=103.1± /MAINTAIN 2% SLOPE OVER S.A.S. S1=1% (MIN.) 4"SCH40 PVC ®S=1%1(MIN.) 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2" 6" " DOUBLE WASHED STONE ., X51 R-Lilo"I 14" 2' EFF. aa 6" B®;4.8'__�"4' (OR APPROVED FILTER FABRIC) �� S\ N Cr1 s EXISTING 48" LIQUID DEPTH ®a-�3/4" TO 1-1/2" DOUBLE '9 '0' LEVEL cAsADDeAFFLE INV.=101.17 PROPOSED _ INEXISTN1G63± D 4' INV.=101.00 BOX EFFECTIVE WIDTH = 12.8' WASHED STONE �- t5` 4O INV.=100.00 00 CID* � EXISTING SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS /C SURROUNDED WITH STONE AS, SHOWN H-10 RATED ole NOTES: Q��Q Ole 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP CONC. ELEV.=100.8± INVERTS, PRIOR TO INSTALLATION. BREAKOUT ELEV.=100.50 2) D -BOX SHALL BE SET LEVEL AND TRUE TO INV. ELEV.=100.00 GRADE ON A MECHANICALLY COMPACTED SIX 0®0063®0 Im INCH CRUSHED STONE BASE, AS SPECIFIED IN BOTTOM ELEV.=98.00 310 CMR 15.221(2). 4' 2 x 8.5' = 17.;0' 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 25.0' PERVIOUS MATERIAL 4' - SEPTIC LAYOUT 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 5' (MIN.) ABOVE G.W. LEACHING SYSTEM SECTION NO G.W., EL=89.7 -L®®®® ® ®®®® SEPTIC SYSTEM PROFILE ®®®®®®®®®®® 33" d.w ®®®®®®®®®®® N Z ® L- I a N.T.S. if SOIL LOGS DESIGN CRITERIA 102" DATE: 6/14/01 DATE: 2/28/19 SOIL EVALUATOR: JOSEPH REGO SOIL EVALUATOR: PETER McENTEE NUMBER OF BEDROOMS: 3 BEDROOMS WITNESS: A. VON HONE R.S. WITNESS: A. VON HONE R.S. 4" KNOCKOUT HEALTH AGENT HEALTH AGENT SOIL TEXTURAL CLASS: CLASS I ELEV. OLD TP DEPTH ELEV. NEW TP DEPTH 20" DIA. COVER DESIGN PERCOLATION RATE: <2 MIN/IN 102.3 0" 103.5 0" A 4" KNOCKOUT 4" KNOCKOUT 58" DAILY FLOW: 330 G.P.D. FILL LOAMY ND DESIGN FLOW: 330 G.P.D. 101'0 A 16" 103.0 R 52 6" GARBAGE GRINDER: NO -not allowed with design SANDY LOAM 1oo.s 10YR 4/2 B MED. MED. AN D SAN 4" KNOCKOUT 20„ LEACHING AREA REQUIRED: (330) = 445.9 S.F. BLOAMY SAND 101.7 C1 22 74 10YR 4/6 PERC 500 GALLON CAPACITY, H-10 LOADING EXISTING SEPTIC TANK: 1500 GALLON CAPACITY 0 100. c1 28" MED. SAND 2.5Y 6/6 30"/48" CHAMBERS PROPOSED D -BOX: 1 INLET, 3 OUTLETS, H-10 RATED E PERC 97.2 76" 43"/61" C2 USE 2-500 GALLON LEACHING CHAMBERS IN SERIES VERY SILT LOAM 10YR 5/4 PROPOSED SEPTIC SYSTEM UPGRADE PLAN SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES FINE SAND 96 O 1OYR 6/6 9O 15 HERVEY LINES LANE, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, W. Yarmouth, MA 02673 SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. 91.1 ADJ. GW 0 MED. SAND BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. - 89.7 Z 151" 2.5Y 6/6 Engineering by: SCALE DRAWN JOB. NO. TOTAL AREA: .............................................................. 471.2 S.F. - 92.0 PERC RATE <2 MIN/IN. "C" HORIZON 138" Engineering Works Inc. N.T.S. P.T.M. 103-19 DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD "Cl" PERC RATE <2 MIN IN. HORIZON OBSERVED GROUNDWATER EL.=89.7 / ADJUSTED GROUNDWATER EL.=91.1 NO GROUNDWATER ENCOUNTERED 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 3/5/19 P.T.M. 2 Of 2 �� �auILDINc TYPICAL- DETAILS OF SEWAGE DISPOSAL SYSTEM J U L 13 2001 Ihia .sows' P :'. - _... �f. '` . �• LE orlll la XWrIZ t„ �_ • �I �� I(iaiinaan of (!J doaau /�-/ • T foL10 inssmiion cows - r PVC. To mj tsmd PK unit stun.. (1�rFJ zbuhl. 20' ate. rover. T� ~ltrrt 1:/f wrrr Pot:� rs ec 706 . reonr (tYFJ INSTALL GAS BAFFLE AT OUTLET \L •�S-� 5 G. I--_�----_ __-_-- Callois Glspaci.ty (• • I ®®® I TONE t,rsal{� c�osc J r , DISTRIBUTION 8 U T I BOX : • . �. ' . � ®®®®®® ®®® . • V. ' • s •• • AL, OUTLETS TO 1E TN[ L� • • •• • �.- '•I ' •• •� .. SANE ELEVATION • �+ - j•;•. Water Level Test 4 .. _ �. Tizrr.� to be ins>:alled on a ler+a! 1 e' siDssJ (z u,v/rs Kll (* 010'srmwx /,v Be77.rJrvJ (i. S/DssJ s able • base Amin. B" stone base, �Fi it,7•/vA' Ld'NCTH = 2 8 Al ':i Construction shall conform to 3 Title V requirements Eff,E�iYE, �►/o�y = ��, E/. Z7• o Finish grade to confirm to Title V Section 15.221 (7) where the tops Of any component or soil absorption area shall be installed no more than 30" below finish grade. There are to known or observed wells within 100' Title V requirements (15.211) of the proposed septic system. 42,4 Z(9"Ve -#/'B Im 02S Po f Revised Plan ( 7/12/01 ) No foundations or cellars are located within twenty (20) feet of leaching area. No wetlands within one hundred (100) feet of leaching area. (Z.REEP SOIL. TEST Witnessed : /70 0 PEN:O•ATION'31 `Approved b SIGN DATAIt wet Well Board of Health -7-1 %3-17/ Number of bedrooms.• J? INVERT ELEVATIONS:' Estimated daily ef, jiuent.- -?30 6!P1� Total Leaching a rlra - as prvpased• - INV A BUILDING _ 6.c'�wa11• S(Lf)'J x 0 _. 1.5 S- INV 9 SEPTIC TANK Iq 0 _ NV_QESP I _7ANK U},1 Bottom- L s Y= 0,3 8 S.F. q • INV �g o BOX ,(11 L 44.,5'0 Leach. ng Capacity DIS pmpOsed- A.T k�tINV 3NS. FA **LITY (-fJiuerd loading =te = 0.74CAVIZ ) -- - - SideWall.' 1.5-6.. s 0.9'4 Bottom.-� Dg. s • 0.74 = 227, 9 DESIGN CRITERION TOTAL = '9610 SOIL CLASSIFICATION ;')EEP TEST HOLD PLUMBING FIXTURES a APPLIANCES See attached by Kevin Mullaney AUTOWATIC WASHER (Sol] Evaluator) DISHWASHER 4 ¢ GARBAGE GRINDER GRO.r+J WATER ELEVAYION "(.! SEPTIC TANK DATA PERCOLATION RATE TYPE - PRECAST REINFORCED CONCRETE HOLE No. I. <*? Min/inch CAPACITY I'500 GALLONS LOCUS (No SCALE) I MAP 6-9' PARCEL /¢ I JOSEPH H. REGO 85 Cooks Amk Rd. • P.O. Bo: 1656 N, • EASTH&%f. SLUSSAMSETIS 026S I T0100011e: 5080W5.3803 DISTRIUUTION BOX DATA TYPE - PRECAST CONCRETE. In Of l Z. 3 a PLUGGED OUTLETS _3_ OWNER: ACCEPT RED A