HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
_ - SEWAGE PrN REVIEW CHECKLIST
Location: A.M. 5 Lot //9 Zone of Contribution: In Out �reage
/ Commercial: Residential:
/D
Street: / (: UC-//�? � C,....-------if
�
Village: /if Floor Floor Plan: V #Bedrooms:
Owner: Y Installer:
ls„...6
Address: Phone:
I Phone:
Builder: Engineer: ,2 ,
Address: Phone: �� � '-
Phone: ✓(/// C „, 17 � 1, ,491-
� /�(` 5���"7
N/A YES NO
1.Required#of copies received tom/
2. Date of soils exam and percolation test not older than 2 years _ f..._.---
3.4-5
.---3.4-5 ft of naturally occurring pervious material, above water table L'-'7-
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1/4..__`.-1
5. Water line 10 ft from septic components Var.: ‘..._....----
6. Benchmark indicated and shown-NGVD if near wetlands /'
7. Septic tank minimum 10 ft from foundation, deck Var.: a cG s tL,G
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: \-/
9.Leaching minimum 100 ft from wetlands Var.: l. .
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t....._.....--
11.
r11. Tank/leaching minimum 10 ft from property line Var.: �� t----'
12. System meets all other setback requirements Var.: Le
13.Uses adjustment for maximum high groundwater Var.: 6 .3f '- g____..c.-----
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal (....----
16.
f16.Proposed contours are suitable
--1.....------
17.
.-->17. System meets slope requirements-min. 1/8", 'A"preferred t. ----
18. System meets breakout requirements PVC liner: Wall: �--.
19. Specified tee sizes are proper, gas baffle on outlet tee
L.------
20. Sewage is under 10,000 gpd for parcel l_-
- 24.No garbage disposal L- ----
22. System adequately sized for its intended use �,,_.
23.Minimum 6"stone or compacted below tank and dbox k•-___--.
24.Manhole covers within 6"of grade,pump chamber cover to grade L------"
25. Inspection port on plastic chambers/leach field (..-r
26. Electrical permit for pump chamber/Separate meter for duplexes �---•
27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed ------
29.Vent provided if leaching below 3 feet,under driveway/parking �----'
30.Buoyancy calculations for tank/pump chamber _ `�
31. Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature _ L��•
35.Foundation footing min. 2 feet above adusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assess is Map
Plan reviewed by: 6/03/03