Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH - SEWAGE PLAN-REVIEW CHECKLIST E Location: A.M. /0/ Lot Zone of Contribution: In • Out_ Acreage " . 2 . Commercial: Residential: Street: q-g pt, 4/5 /7"/ Village: ` Floor Plan: C. #Bedrooms:_ Owner: A.elege,/‘Kgier,1/- Installer: Address: Phone: ' Phone: I LL D. / Builder: 7 / Engineer: i ` i Address: Phone: P' _3- _ 5:1Phone: >...) N/A YES NO 1.Required# of copies received ‘.....---- 2. Date of soils exam and percolation test not older than 2 years t.... 3. 4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1/4......-- 5. Water line 10 ft from septic components Var.: C-----• 6. Benchmark indicated and shown-NGVD if near wetlands ...._.....- 7. �7. Septic tank minimum 10 ft from foundation, deck Var.: t.....---' 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l.......-- 9. Leaching minimum 100 ft from wetlands Var.: c..------- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ‘.--- 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: y7.-- 14. Leaching set 4-5 ft above adj.water or bottom o - o Var.: L/ 15. System not in top or subsoil(A,B horizons) o 5'remova . pie1 Otice , L----"*.a4 L 16.Proposed contours are suitable k...------ 17. �17. System meets slope requirements-min. 1/8", ' "preferred �.---- 18. System meets breakout requirements PVC liner: ' all: �---• 19. Specified tee sizes are proper, gas baffle on outlet tee Lam' 20. Sewage is under 10,000 gpd for parcel Com• 21.No garbage disposal ®- ? 22. System adequately sized for its intended use (...® 1 23. Minimum 6"stone or compacted below tank and dbox <.--- 24.Manhole covers within 6"of grade,pump chamber cover to grade <......-- 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes ,_----• 27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size �----• 28. Septic tank/pump chamber to be factory waterproofed s.---- 29. Vent provided if leaching below 3 feet, under driveway/parking ®► 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: ..-----. 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature - C �--1") 35.Foundation footing min. 2 feet above adjusted ground water for new house -- 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Ma < �� Plan reviewed by: 6/03/03