HomeMy WebLinkAboutReview Checklist - �( / TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
•Location: A.M. 64 Lot /IP Zone of Contribution: In Out eage
/4 5-4,0741elef ' Commercial: Residential:�`Street:(�
Village: Y:00' V Floor Plan: / #Bedrooms: 2/
Owner: 66(4 Installer: 4/
Address: Phone: 7-7 - : 4W/
Phone:
Builder: Engineer: e-Z �" '"/ G 0....i.„
Address: Phone: f77'-4 /j'
Phone:
N/A YES NO
1.Required#of copies received t..----
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material, above water table L.---
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands L----*
7. Septic tank minimum 10 ft from foundation, deck Var.: L.-----
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ��
9.Leaching minimum 100 ft from wetlands Var.: -- '"'
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ---- --
11.Tank/leaching minimum 10 ft from property line Var.: `,_..----
12. System meets all other setback requirements Var.: ...-----
13.
..-✓13.Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: -
15. System not in top or subsoil(A,B horizons)or 5' removal 1/4.---
16.Proposed contours are suitable C._.
17. System meets slope requirements-min. 1/8", '/4"preferred L.,-
18.
l18. System meets breakout requirements PVC liner: Wall: L-----
19. Specified tee sizes are proper,gas baffle on outlet tee c_._s'
20. Sewage is under 10,000 gpd for parcel -----
21.No garbage disposal (.-------
22. System adequately sized for its intended use L/
23.Minimum 6"stone or compacted below tank and dbox 4.----
24.
.--o24.Manhole covers within 6"of grade,pump chamber cover to grade
(......---
25.
r25. Inspection port on plastic chambers/leach field L-----
26.
i26. Electrical permit for pump chamber/Separate meter for duplexes �1
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size `✓
28. Septic tank/pump chamber to be factory waterproofed ✓
29.Vent provided if leaching below 3 feet, under driveway/parking _-----
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature `_..-----4
33.H-20 loading is subject to vehicular traffic, groundwater �''
34.Title V Application and permit fee, installer signature - �®-'
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's /Map
Plan reviewed by: `�CiCJr 6/03/03