Loading...
HomeMy WebLinkAboutEngineered Plans - 2019n FLOOR PLAN Yarmouth Health Department APP WED ame Date 4 -lox - tzq SURVEY CONDUCTED BY. WELLER AND ASSOCIATES SOUTH YARMOUTH LEGEND -(-� PROPOSED CONTOUR ® PROPOSED SPOT GRADE EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE 19 TEST PIT SCALE: 1"=20' Yarmouth Health Department APP WED ame Date 4 -lox - tzq SURVEY CONDUCTED BY. WELLER AND ASSOCIATES SOUTH YARMOUTH CAPE NOYES RD LOCUS MAP LOCUS INFORMATION PLAN KtF: Z10/1ZU TITLE REF: 2503/088 PARCEL ID: MAP 067 PAR. 101 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 22 CAPTAIN BEARSE RD. SOUTH YARMOUTH, MA PREPARED FOR CLIFFORD EXC/ROY APRIL 19, 2019 taKl"' % L-1 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmaii.com SHEET 1 OF 2 894 BEARSE RD. A c -i CAPE NOYES RD LOCUS MAP LOCUS INFORMATION PLAN KtF: Z10/1ZU TITLE REF: 2503/088 PARCEL ID: MAP 067 PAR. 101 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 22 CAPTAIN BEARSE RD. SOUTH YARMOUTH, MA PREPARED FOR CLIFFORD EXC/ROY APRIL 19, 2019 taKl"' % L-1 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmaii.com SHEET 1 OF 2 894 ELEV. TOP FOUNDATION (Existing) - 18.50 - , ,--F.G.EL- 17.10 EXISTING OUTLET INV. 15.1 10" NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE F.G.EL.: 16.5 F.G. EL: 17.0 TEE'S ARE TO BE 14 I NV. $r5 �� ® S 4" SCH 40 PVC INV. 14.85 INV. GAS PROPOSED DB -3 BAFFLE DISTRIBUTION BOX (H20) EXISTSING 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON ���`� OF OUTLET TEE AS MANUFACTURED BY �y TUF-TITE, ZABEL, OR EQUAL o DARKEN M. YE NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING -' N PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2),�1/� 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK 1 WITH 1500 GALLON SEPTIC TANK IF FAILED, SEPTIC SYSTEM PROFILE DAMAGED OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED) FINISHED GRADE (17.0) MAINTAIN 296 MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 1% (MIN.) 2' EFF. DEPTH INV. ELEV.= 13.50 aa® 4'/ 1 2X8.5' 3/4" - 1-1/2' DOUBLE WASHED 4' I / EFFECTIVE LENGTH = 25' 1 TOP CONC. ELEV.= 14.50 INV. ELEV.= 13.50- BOTTOM EL.= 11. SEPARATION 5.50 FT. BOTTOM OF TESTHOLE EL: 6.00 SOIL LOGS DATE: APRIL 17, 2019 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH DEPT. Eley. TP -1 Depth 17.00 A 0" LOAMY SAND 16.33 IOYR 4/1 8" B LOAMY SAND IOYR 6/8 14.33C 32" MEDIUM SAND PERC 7E5T 2.5Y 7/3 O EL 13.50 6.00 132" PERC RATE <2 MIN/IN. ("C1" HORRON) NO GROUNDWATER OBSERVED I, Damn M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct sail evaluations and that the above analysis has been perfonned by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam In October, 1999. BREAKOUT ELEV.= 14.50 3.75' 5 FT. 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR - DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 550 gpd x 200% = 1,100 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25 x 12.5= 312.5 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED - 462 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(462 S.F.) - 342.25 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 22 CAPTAIN BEARSE ROAD, SO. YARMOUTH, MA Prepared for: Clifford Exc Ro Design and Site Plan by: SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 04/19/19 PO BOX 981 REV DATE EAST SANDWICH, A44 02537 CHECKED SHEET N0. 508-362-2922 DMM 2 of 2