HomeMy WebLinkAboutEngineered Plan - 2019GENERAL NOTES: A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM UNLESS H-20 COMPONENTS ARE USED. B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- LESS CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING. C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. CONSTRUCTION NOTES: 1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. 2.) SEPTIC TANK(S) GREASE TRAP(5) DOSING CHAMBER(S) AND DISTRIBUTION 501L TEST LOGS: TEST HOLE 1: EL=55.6± DEPTH FROM SURFACE (INCHES) SOIL HORIZON 501L TEXTURE (USDA) SOIL COLOR (MUNSEW SOIL OTHER MOTTLING 10-17 A Fine, Loamv Sand I OYR 312 NONE 17-52 B Fine Loamy Sand I OYR 5/8, NONE 52-156 I C Fine to Medium Sand I OYR GIG I NONE PERC 72" <2 rn, in TEST HOLE 2: EL=55.2± :PTH FROM SOIL SOIL SOIL SOIL OTHER )RFACE HORIZON TEXTURE COLOR MOTTLING INCHES) / (USDA) (MUNSELL) OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE.. 0-12 A Fine Loamy Sand I OYR 3/2 NONE 12-51 B Fine Loamy Sand I OYK 5/8 NONE 51-144 C Fine to Medium Sand I OYR G/2 I NONE NO G.W. ENCOUNTERED BOXES) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY DATE OF TESTING: 2/20/19 COMPACTED, OR ON A G INCH CRUSHED STONE BASE. PERCOLATION RATE: LESS THAN 2 MIN/INCH IN 'C' LAYERS. 3.) SEPTIC TANK(S) SHALL MEET ASTM STANDARD C 1 127-93 AND SHALL HAVE WITNESSED BY: MATTHEW J. WROBEL; EIT, J.M. O'REILLY �- ASSOCIATES, INC. AT LEAST THREE 20' DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT- PHILUP RENAUD, AGENT, HEALTH DEPARTMENT NO WATER ENCOUNTERED TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM. 4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G" / ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE PLANCENTERLINE VIEW OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE.. ONE (1) SAS COVER 5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST„ TO BE BUILT UP TO SCALE: I = 10' WITHIN 6 OF FINISH CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN G" OF FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. i GRADE G) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT PIPE SHALL / BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN I%. NOT TO SCALE 7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE / 4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT. UNE SHALL BE CAPPED RAISED TO WITHIN G" OF FINISH AT END OR AS NOTED. 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 2' BEFORE PITCHING TO SOIL ABSORPTION SYSTEM, WATER TEST DISTRIBUTION / BOX TO ASSURE EVEN DISTRIBUTION. o �, 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF G" MEASURED BELOW THE OUTLET INVERT. 10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 3/4" TO I-1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST AND SHALL BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE % SOIL ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH A 2" / LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST. / 1 1.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET; WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRJVEWAYS,.PARKING AREAS, NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN. TURNING AREAS OR OTHER IMPERVIOUS MATERJAL; OR WHEN PRESSURE DOSED. 12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF CLEAN MEDIUM SAND (EXCLUDING TOPSOIL). INSTAw 13.) FINISH GRADE SHALL BE A MAXIMUM OF 3G" OVER THE TOP OF ALL SYSTEM NOT TO SCALE COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER IL_ AND 501L ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20 Rated) OF 9". 14.) FROM THE DATE OF INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL COPLAN RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP- TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH DEED BOOK 28392 PAGE AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. o 15.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION BY.AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF THIS SYSTEM RE- QUIRES A VARIANCE) AND MAY REQUIRE SUCH PEP50N TO CERTIFY IN WRITING CD THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED. LEGEND I G.) 501L REMOVALS ALL (A) * (B) SOIL HORIZONS SHALL BE REMOVED DOWN TO THE FINE TO MEDUM SAND (C), FOR A DISTANCE OF 5' FROM THE SOIL ABSORBTION SYSTEM, AREA TO BE BACKFILLED WITH CLEAN SAND AND COMPACTED TO MINIMIZE SETTLEMENT 17.) INSTALLER SHALL VERIFY INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY SEPTIC SYSTEM COMPONENTS. 18.) INSTALLER SHALL CONTACT DESIGN ENGINEER TO VERIFY SOIL CONDITIONS IN THE BOTTOM OF SAS EXCAVATION PRIOR TO INSTALLATION OF ANY SEWAGE DISPOSAL SYSTEM COMPONENTS.. 19.) EXISTING SEPTIC TANK, EXISTING 1500 GALLON SEPTIC TANK TO BE REUSED. THE SEPTIC TANK SHALL BE PUMPED * CLEANED. NEW INLET AND OUTLET TEES AND OUTLET GAS BAFFLE INSTALLED. COVERS ON INLET AND OUTLET END OF THE TANK BUILT UP TO WITHIN G" OF FINISHED GRADE. 19.) RESERVE AREAS RESERVE AREA IS G3' X G.53'= 430.3 S.F. CONSISTING OF (G) SIX 4.83'X 8.5' CHAMBERS WITH 1.0' OF STONE SURROUNDING THE CHAMBERS AND 2' OF STONE BETWEEN CHAMBERS. 20.) EXISTING WA5TELINE(5)i INSTALLER TO CONFIRM WA5TELINE(5) BY WATER TESTING WITHIN THE DWELLING PRIOR TO SETTING ANY SYSTEM COMPONENTS. FLOW PROFILE: NOT TO SCALE 5x (G) 18' DIAMETER CONCRETE COVE T070FOUNT ATl011 RAISED TO WITHIN G" OF FINISH 1500 GALLON SEPTIC TANK (EXISTING) GRADE (OR AS NOTED) 55.7± (5EE NOTE #5) o �, d Proposed EL= 54.5 ONE (1) 33.5'X 12.53'X 2.0' LEACHING CHAMBER CAN LEACH: n Vt=I(33.5 X 12.83) + (33.5 X 2.0)2 + (12.83 X 2.0)2] X 0.74 GPD/5F=455.1 O GPD 455 GPD>440 GPD REQUIRED LOCUS 52.'7 52.3+ (�Y,15 ii .) (i.X15 .) FJ _ I I- I i I•I 14 310" " 410" PROPOSED T GAS BAFFLE 4� OUTLET TEE - 'ROPOSED 4" PVC INLET TEE 1500 GALLON . SEPTIC TANK (EXISTING) TO REMAIN Bath Bath Room Room Kitchen Kitchen I_ Living Room Living Room Closet Closet FIRST FLOOR Bedroom Bath Bath Bedroom Bedroom - = Bedroom 0 0 U U -- SECOND FLOOR EL=54.2± ` L X2.1 Ip" I4' (EX15 T :) 3.. 4'0� T 51 .9l IGAS BAFFLE 8 I 1000 GALLON f SEPTIC TANK Utd€ty Room Utility Room Unfinished = Unfinished Basement - Basement BASEMENT S. Yarmouth, MA SYSTEM DE51GN CALCULATIONS: SEWAGE DESIGN FLOW, 4 BEDROOM DWELLING @ 110 GPD = 440 GPD S�d� LEACHING CAPACITY REQUIRED ➢ X0,9 4 BEDROOMS (MAX.) @ 1 IQ GPD = 440 GPD REQUIRED co Ofd Town House Road L� SEPTIC TANK CAPACITY REQUIRED DAILY FLOW = 440 GPD @ 200% = 880 GAL. REQUIRED 5 arrow Way SEPTIC TANK CAPACITY PROVIDED < 1500 GALLON SEPTIC TANK (EXISTING) 1000 GALLON SEPTIC TANK (PROPOSED) o �, LEACHING CAPACITY PROVIDED ONE (1) 33.5'X 12.53'X 2.0' LEACHING CHAMBER CAN LEACH: n Vt=I(33.5 X 12.83) + (33.5 X 2.0)2 + (12.83 X 2.0)2] X 0.74 GPD/5F=455.1 O GPD 455 GPD>440 GPD REQUIRED LOCUS NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN. N INSTAw °' NOT TO SCALE ONE (1) - 1000 GALLON SEPTIC TANK IL_ ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20 Rated) THREE (3) - 500 GALLON LEACH CHAMBERS WITH 4' OF STONE ALL AROUND COPLAN BOOK 231 PAGE 27 N DEED BOOK 28392 PAGE o ASSESSORS' MAP 87 PARCEL 123 CD L IL LEGEND Approximate Location .. ... of Abandoned Leach Pit ____- 32 -- . EXISTING CONTOUR PROPOSED CONTOUR 32 UP #81 I p 1 .72' o ,� x 12.34 EX15TIING SPOT GRADE 2.9 O. _-'1 . 1 24x5 PROPOSED SPOT GRADE 56.8-- W- WATER SERVICE LINE 52.2 °h ---Fence__ \ Exi55eFtic 1500 Gallon 5ept,c Tank _o- OVERHEAD UTILITY SERVICE \ r Stockade -____----- \ � � To REMAIN IN USE -u- UNDERGROUND UTILITY SERVICE (SFrKInTF -41 PI � x 55.3 1 1 GAS SERVICE LINE 0.72'± \oy'-� \ Ste � •_'/ 55.7x ® TEST BOLE J BORING LOCATION ! h 2 ST SEPTIC TANK � � .54.3 t 1 56.1 1 , DB DISTRIBUTION BOX 1 ` s 53.0 0 \o IDeck® \s SAS SOIL ABSORPTION SYSTEM Faved DrNeway Reserve t a ►+ i O RESERVED FOR FUTURE EX,yt,ng CP 1 o ° UTILITY POLE i <� ` x 54.s Stockade Fence ® CATCH BASIN 1 ` 51,4 f ; ® CONCRETE BOUND, FOUND 5 54. 0 _x -x_ ��yt'ng LIMIT OF WORK 52.3 ( I \ Bedroom . i i �l pg N Mult,-Family Dwelling .--- J -- FENCE rn ` Exstmg TOF EL = 55.7±r_ a 5 -� N ^�.^EDGE OF CLEARING CConcrete -- 1 Walkway �, \ \ \ , aI I ` ! I O + 1 54.2x 1 1 -s x 52.6 OI 13 5T 1 ! 1 9 I! D I 1 X 3.3 s� �, I I N \ ! 0 v`r m �! �I'I�54 I-1'=� 1 \ 3.9 Exist€ng Sewage Disposal 1 i -.\ r V °�, Deck I NO L- -53-.9 system (Per BOH Records) (� 1 SAS TO BE REMOVED veway/ �Ii1i.l 1} L t . t Paved Dn - . `.. Existing o ° 52.0 nco / x 5 o j/ PROPOSED 1000 GALLON `� ►' 0.3 °Clear,ng 2.6 O ' 0 �/� 53.5 SECONDARY SEPTIC TANK �` ¢ 0s5011 einov, FLOOR PLAN NOT TO SCALE 1 550 2" DF i`-17'. DB -3 FH -201D -BOX or \ de Fence 4.0 5tocka 52.8 51.5 ` 52.3 � P- �QA51-/ p2.�� 1+ SCALE I 20 J T,7E UPI 49.3 52 THIS AREA 15 SERVED *W =iC _.� .2- � �0 BY TOWN WATER. NammeDate 1 o BENCHMARK: 49.0 Top of Foundation �m�� I EL=55.7-±- (Assumed Datu OF N%s` OFps\ate sir JOHN rIN N7. S 0 20 40 GO 41� O'R ILL`S " `� SCALE 1"=20' NO. 46733k e Pti�?.35203 d EL=53.3 ,,,Proposed EL=53.3 suVE BUII.�Ing DrealTlS, Inc. 24" Proposed C/O Mike W111iam5, 20 North Main Street, South Yarmouth, MA 02GG4 51.3 (9' Min - 3G Max) 51TE SEWAGE D15P05AL 5Y5TEM DESIGN / 2" LAYER OF 1/8" - 1/2" STONE 10 12 Ventura Way, South Yarmouth, MA 02GG4 /50.55, j 3/4" - 1-1J2" STONE j N N J.M. OTEILLY &;ASSOCIATES, INC. 48.5 INSPECTION NOTE: Professional Engineering & Land Surveying Services USE THREE (3) SHOREY PRECAST PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM 500 GALLON LEACH CHAMBERS 5.9'± NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. 1573 Main Street - Route 6A Longest Run WITH 4' OF STONE AROUND P.O. Bog 1773 - 15' (508)896-6601 Office Brewster, MA '', 02631. (508)896-6602 Fax (ENE) VIEW) DATE: SCALE: BY: CHECK: JOB NUMBER: LEACHING CHAMBER - EL=42.G± BOTTOM OF TP #I 33.5'x 12.83'x 2.0' GA\AAJobs\Williams - 8G87 - I O� 12 Ventura Way 5. Yarmouth\dwg\8G87.SD5 Plan.dwg 3/11/201 9 AS Noted MJW JMO JMO-8687