Loading...
HomeMy WebLinkAboutEngineered Plan - 2019N rd u FLOOR PLAN / 28. T5M = EL. 30.0 BULKHEAD FOUNDATION 0.? 28.7 @0) o *° 28.9 \sem \`F nn h� JV Q- C� vJ 4 �O Q Yarmouth Health Department Date PLAN SCALE: 1 in = 20 ft 0 20 40 0 10 20 40 WEST YARMOUTH R0� 2 moo moo. 'LOCUS 51 PROSPECT AVE Q � m LOCUS MAP LOCUS INFORMATION PLAN REF: 072/007 TITLE REF: 15123/158 PARCEL ID: MAP 022 PAR. 079 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 51 PROSPECT AVENUE WEST YARMOUTH,MA PREPARED FOR DONE RIGHT EXC. APRIL 9, 2019 DA RM. N 1 4w,*TVIT MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 894 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT @0) o *° 28.9 \sem \`F nn h� JV Q- C� vJ 4 �O Q Yarmouth Health Department Date PLAN SCALE: 1 in = 20 ft 0 20 40 0 10 20 40 WEST YARMOUTH R0� 2 moo moo. 'LOCUS 51 PROSPECT AVE Q � m LOCUS MAP LOCUS INFORMATION PLAN REF: 072/007 TITLE REF: 15123/158 PARCEL ID: MAP 022 PAR. 079 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 51 PROSPECT AVENUE WEST YARMOUTH,MA PREPARED FOR DONE RIGHT EXC. APRIL 9, 2019 DA RM. N 1 4w,*TVIT MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 894 Q NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK T.O.F. EL.=30.01 INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE F.G. EL.=28.8± F.G. EL.=28.2± F.G. EL: 101.0± 9" MIN COVER/ 36" MAX COVER b L = 35' L 10'(MAX) O S=1X (MIN.) EL=27.35± O S=1X (MIN.) O S=1X (MIN.) 4"SCH40 PVC n 4"SCH40 PVC Irl 4"SCH40 PVC INV.=26.31 J1 " '8" LIQUID INV. =26.06 i.1ISL GAS BAFFLE EXIST. SEWER OUTLET INV.=27.67 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,500 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 11.3" TO INVERT INV.=25.44 - PROPOSED D -BOX `INV.=25.54 .(H2O) BREAKOUT=TOP ELEV.=25.83 INV. ELEV.= 25.44 BOTTOM ELEV.= 24.50 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:98.0 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL: 101.0(MAX.) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (6.65' PROVIDED) ADJUSTED GROUNDWATER EL 19.45- 4) INSTALL INLET & OUTLET TEES W/ SEPTIC SYSTEM PROFILE GAS BAFFLE AS REQUIRED N.T.S. DESIGN CRITERIA / NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL- 3 BEDROOMS 0 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (1-120) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE PROP. 1,50OG SEPTIC TANK I LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. b PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473 SF TOTAL AREA = 473 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER -BACKFILL WITH CLEAN PERC SAND EXISTING SUITABLE 2.83' I MATERIAL EFFECTIVE WIDTH = 4 x 2.83' = 11.3 USE 4 ROWS OF 4 -HIGH CAPACITY INFILTRATOR (H20) UNITS TYPICAL SECTION 1 KTS SOIL LOGS DATE: NOVEMBER 28, 2019 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH DEPT. Elev. TP -1 Depth 28.05 0" C MEDIUM FILL 27.47 7" C2 MEDIUM A LOAM 26.99 _ 1 OYR 3/1 13" PERC TEST O EL 23.63 17.05 LOAMY SAND 10YR 5/6 22" C MEDIUM SAND IOYR 5/4 90" C2 MEDIUM SAND 2.5Y 7/4 132" PERC RATE <2 MIN/IN. ("C" HORIZON) GROUNDWATER OBSERVED AT 132" EL 17.05 WEU-• MIW-29 ZONE: B LEVEL: 8.1 ADJ. 2.4' ADJUSTED GROUNDWATER EL 19.45 • 1, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. N41 OF GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. B. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACH PR TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING SECTION INfVFRT J HEIGHT END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 51 PROSPECT AVENUE, WEST YARMOUTH, MA Prepared for: Done Right Excavation System Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 04/09/19 PO BOX 981 EAST SANDWICH, MA 02537 CHECKED SHEET NO. 508-362-2922 DMM 2 of 2