Loading...
HomeMy WebLinkAboutEngineered Plans - 2019Wells not shown exceed 150' from the proposed SAS IV.,\ rn M 0 - 51.0 CONVENTIONAL SAS /5' X 30' X a5' PROPOSED LEACH/NG F/E,L 23.0'L x/5.0'Wx0.51D 4 ROWS OF 3 -CUL TEC CONTACTOR /00HO (SET ROWS /. 0' APART) / PUMP S REMOVE EX/ST/NG LEACH/NG AREA S ALL CONTAMINATED SOLS w/TH/N 5' of PROP. SAS � I F PROPOSED /000 -GALLON 51.1 16,„ PUMP CHAMBER (H-/0) LOT 55 10,634 SFf NOTE. 0.24 Acf * This property is not located within a Zone ll, Drinking Water Protection District SCALE: 1" = 20' 0 20 40 60 ® 2019 Moran Engineering Associates, LLC PUMP S RETAIN EX/ST/NG /000 -GALLON SEPTIC TANK 49.6 �'y e 49.0 o; (S ,o , C) �o � o � � a \/ 49 BENCHMARK: EI. 49.4 (Assumed Datum) Top of Concrete Step Yarmouth Health Department 11W,P)WVED Fill STIAlr- 97 nnP l d Ynl lT /V. /.J. Deed: Book 27824, Page 329 Plan: Book 91, Page 41, Lot 55 LEGEND 25 Molly Road West Yarmouth, MA PREFAB® FO& Danielle Fahle 32-29 1 SHEET 1 of 2 5/7/2019 1 19-086 Moran Engineering Associates, LLC 941 Route 28 N PO Box 183 South Harwich, MA 02661 508-432-2878 Existing Building " ' ' ' ' Edge of Driveway 50 Existing Contour F Existing Septic Tank ® Proposed Pump Chamber WANNOWNWhi Proposed Leaching Area 23.0' L x 15.0' W x 0.5' D 46.9 Existing Spot Elevation --- oHu — Overhead Utility Lines -- w — Existing Water Line --- c — Existing Gas Line } Existing Fence Line Septic Test Hole 51TE AND SEWAGE PLAN 25 Molly Road West Yarmouth, MA PREFAB® FO& Danielle Fahle 32-29 1 SHEET 1 of 2 5/7/2019 1 19-086 Moran Engineering Associates, LLC 941 Route 28 N PO Box 183 South Harwich, MA 02661 508-432-2878 7W 0 x-48.0 �47. 25 t EXISTING SEPTIC TANK PROPOSED PUMP CHAMBER " X EFFLUENT FILTER POWER SUPPLY FOR MANHOLES WITH COVERS 10 GRADE 10 BE LOCATED OVER PUMP FLOATS, k ALARM ALARM �-�� PIPE UNION FOR M LOCIaNG OR 80.7m TO COVERS ME REQUIRED TO BE COVER To aRAOiE _ C,I 5jy �I - n ..1 , h. Jf, Q'50.5 1 4TrENFIHAM�� LEACH FACILITY Irrigation CULTEC CONTACTOR 1OWD Control Box 4' PVC PULL CAP. END PLUG OR CLEANOUT. 4' SCH. 40 PVC OR 5� Of MIN 2% SLOPE SDR -35 PVC PIPE RISER OVER TO eL W IMIn b' OF GRADE A EFFLUENT FILTER SEPARATE ELECTRIC LITJES TE VALVE • . - . HOR. TEXTURE w ZabrJ AIOO- a x 19 TO PUMP AND FLOATS 5110• DRAIN HOLE 50,1 8' A w/ FILTER ALARM 10 YR 2/2 NO 46 g MIN. 9' COVER Bw Loamy Medium Send 4" SCH. 40 P.V.C. NO MAX 38' COVER .: 4' SCH. 40 P.V.C. EL• 49.2 Medium Sand EL -49.3 GWE @ 115' Loose, Sing1e Glair) 3. S = 0.01 EL 49.0 10' 1s'=ootMT�1. 405 - GALLON EMERGENCY CAPACITY 2W ABOVE ALARM EL.47.2 2' PVC OUTLET 1.00D 4.0' J E447.3 CONTROL FLOAT t;Typ CALLON 219° - ALARM LEVEL a- 48.8 C HM VALVE (Typ 23' - PUMP ON PROVIDE SPLASH GUARD FJ 47.2 HOIST CHAIN 18' -PUMP OFF EL 48.3 FILTER BELOW SUMP IOR NLET LINESFABRIC :::::::::.-•::-::::::::::.-:::•:•: _;;fit'`:;.:" a-•`'^s#i:;8. SEPTIC TANK NOTES 1. Replace tees if corroded. Extend inlet tee 10' min. below flow One. Install effluent fitter Zabel A100 8 x 18. 2. Provide 20" manholes over inlet and outlet with readily removable impermeable covers. 3. Install access port over inlet with precast concrete or equivalent watertight riser within 6' min. of final grade. Install cover to grade over outlet Cover must be Iocidng or bolted to rider DEEP HOLE LOGS TEST HOLE 11 TEST BY: CALEB PAUS DATE: 5/1/19 5�0.8 Sues HOR. TEXTURE (MUNSE�LL) STRUCTURE MOTTLING CONSISTENCY, OTHER 50,1 8' A Loamy Sand 10 YR 2/2 NO 46 g 24' Bw Loamy Medium Send 10 YR 416 NO A-) A 99' C1 Medium Sand 10 YR 618 GWE @ 115' Loose, Sing1e Glair) Bot. of Perc: See Test Hole 2 Results RATE: < 2 MIN/INCH Assumed, CLASS I SOIL LOADING RATE: 0.74 GPD/SF WITNESS: P. Renaud, H.A., Yarmouth Health Department TEST HOLE 12 TEST BY: CALEB PAUS DATE: 5/1/19 STRUCTURE �. Sur-Rm HOR. TEXTURE (MUNSELL) MOTTTTLLING COINS/STENCY, OTHER 50.8 10' A Loamy Send t0YR2C1 NO 49A 28' Bw Losmy Medium Sand 10 YR 416 NO 44.9 Sir C1 Medium -Coarse Send 10 YR 616 GWE O 124' Loose, Single Cxain Bot. of Perc: 50' (Cl Layer) RATE: < 2 MIN/INCH. CLASS I SOIL LOADING RATE: 0.74 GPD/SF WITNESS: P. Renaud, H.A, Yarmouth Health Department ESTIMATED HIGH GROUNDWATER CALCULATION (USGSICCS METHOD) INDEX WELL: # MIW-29 ZONE:_ DATE OF READING: 4/2019 DEPTH TO GROUNDWATER: 6.9 GROUNDWATER LEVEL ADJUSTMENT: 1.2 ACTUAL GROUNDWATER LEVEL @ SITE EL= 41.3 ESTIMATED (MAX) HIGH GROUNDWATER LEVEL EL= 42.5 2019 Moran Engineering NOT TO SOME USE 1000 -GALLON PUMP CHAMBER PUMP: USE MYERS SRM4 ALARM IN HOUSE ON SEPARATE CIRCUIT "D' BOX NOTES 1. When system is dosed or dope of inlet pipe exceeds 0.W/ft. install inlet tee cutoff one inch above outlet invert 2. Install outlet pipes level 2 feet minimum. 3. Provide a minimum sump of 6' below outlet invert 4. Install access port over'D' Box with precast concrete or equivalent watertight riser within 6' min. of final grade. DESIGN 1. REQUIRED FLOW *3 BEDROOMS X 110 GPD/B.R = 330 GPD 'EXISTING DWELLING CONTAINS 2 BEDROOMS, 330 GPD MINIMUM ALLOWABLE DESIGN PER 310CMR 15.203(2) 2. SEPTIC TANK CAPACITY 330 GPD X 2.0 = 660 GPD RETAIN EXISTING 1000 -GALLON SEPTIC TANK USE: 1000 -GALLON PUMP CHAMBER (H-10) 3. LEACH FACILITY DESIGN: (3 CHAMBERS X 7.5' I CHAMBER) + 0.5' LENGTH ADJUSTMENT = 23.0 LF PER ROW 23.0 LF X 5.0 SFILF = 115.0 SF 115.0 SF X 4 ROWS = 460.0 SF 460.0 X 0.74 GPD/SF = 340A GPD 340A GPD PROVIDED > 330 GPD REQUIRED USE: (4) ROWS OF 3 - CULTEC CONTACTOR 10OHD CHAMBERS. SET ROWS V APART COVER ENTIRE FIELD WITH CULTEC 410 FILTER FABRIC. BACKFILL TO TOP OF CULTEC'S WITH A CLEAN SAND. INSPECTION PORTS -4 FILTER FABRIC TV EACH UNIT (INSTALLED) r 23.0' LENGTH INSTALLED QJ TFC CROSS MC11ON NATIVE SOIL -n Lawn Box 4" Pull Cap FILTER I Perforated Pipe Chamber To Blinn. of Chamber Use min.: -3/8 Holes O 2' vert spacing INSP. PORT DETAIL 6" 12.5' 5.8' EL 42.5 ADJUSTED HIGH GROUNDWATER NOTES FOR CULTEC 1.) Must be a CerlCuttec Installer. 2.) Cults; No. 410 Filter Fabric or equal AT INVERT approved by Cutter required. GENERAL NOTES 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W/ITTLE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRITING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATION(S) OF UITIMIF.S, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTIIJZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN.1IN. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOL(S) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA. 10.) GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE M MIUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 Fr/FT. 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN 10' OF THE PROPOSED SAS.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT. 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. CONSTRUCTION NOTES 1.) Contact oA%e (508) 432-2878a minimum of 4W-HOVRS A*r to start otprojea 2.) Existing sewer elevations are to be verified prior to the installation of new system components. 3.) Pump & retain existing 1000 -gallon septic tank. Replace inlet tee if corroded. 4.) Pump and remove existing leaching area and all contaminated soil within Y of proposed SAS. 5.) One cubic foot of thrust blocking is required at all force main angle points. 6.) Raise septic tank and pump chamber outlet covers to grade with poly covers bolted to riser or steel covers and rings. Raise septic tank inlet cover, pump chamber inlet cover and distribution box cover to within 6" of finished grade. Leaching field requires four inspection ports with irrigation control box covers to finished glade. 7.) Septic tank inspections: Effluent filter with smart alarm (to be located within the dwelling). 8.) Pump chamber. Extend inlet tee to within 1.0' of the floor of the chamber. Alarm controls are not to be connected to the pump force main. Alarm controls are to be on a separate hanger or pole. Pump chamber is required to be water tested with Health Department and designer present. All electrical lines are to be set in conduit. 9.) Backfill SAS with Title 5 clean granular sand (15.255 (3)). Backfill, loam and seed construction impact areas. A final grade inspection is required. 51TE AND SEWAGE PLAN 25 Molly Road West Yarmouth, MA PREPARED POR Danielle Fahle 32-29 1 2 of 2 5/7/19 1 19-086 Moran Engineering Associates, LLC 941 Route 28 - PO Box 183 South Harwich, MA 02661 508-432-2878