HomeMy WebLinkAboutReview Checklist /" 'i TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST -
Location_: A.M. ,7--->--- Lot j7 Zone of Contribution: In Out_ ci age
Commercial: Residents`
Street: C t..r, `" Cc,,. ',,,, / _ ) ,
Village: a1`l 4 Floor Plan: #Bedrooms:
Owner: ///ll- i y'!/ Installer: n
IA-
Address: Phone: ,,e--- �7 - 7 7
Phone: //®®
Builder: Engineer: � & �tti��/ �� f
Address: Phone: �i 27 -" 7 7
Phone: /WPC 4 � -
N/A YES NO
1.Required# of copies received _
2.Date of soils exam and percolation test not older than 2 years 1./
3. 4-5 ft of naturally occurring pervious material, above water table 1/
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: (.1 _
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: c----
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: ....____-
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -
11. Tank/leaching minimum 10 ft from property line Var.: (9 v
12. System meets all other setback requirements Var.: (..------
13. Uses adjustment for maximum high groundwater Var.: .....-----
14.
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: l..------
15. System not in top or subsoil(A,B horizons) or 5' removal (.-------
16.
,/16.Proposed contours are suitable Ci--
17. System meets slope requirements-min. 1/8", 1/4"preferred C.---'
18. System meets breakout requirements PVC liner: Wall: Lr _
19. Specified tee sizes are proper, gas baffle on outlet tee Lo
20. Sewage is under 10,000 gpd for parcel L..-----
21.No garbage disposal (---------
22. System adequately sized for its intended use k.--i
23.Minimum 6"stone or compacted below tank and dbox ...--- .
24.Manhole covers within 6"of grade,pump chamber cover to grade c_..---
25.Inspection port on plastic chambers/leach field L/
26.Electrical permit for pump chamber/Separate meter for duplexes _
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking -
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial: ......----
32.
.---'32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater �--
34.Title V Application and permit fee, installer signature -
l......--
35.Foundation footing min. 2 feet above adjusted ground water for new house (...---
36.Deed Restriction required max. #bedrooms: max. flow: gpd %..._____
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03