Loading...
HomeMy WebLinkAboutEngineered Plan - 2019LOCUS ��� KEY: �P EXISTING CONTOUR: - - - - OS1G PROPOSED CONTOUR: --------- --• EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 N TEST HOLE: * ON UTILITY POLE: -o- Q�0 . q<i FENCE LINE: - !y G 2 HYDRANT: -6- RETAINING WALL: LOCATION MAP LOT 25 (10,382 SF) ASSESSORS MAP: 49 PARCEL: 129 PLAN BOOK: 135, PAGE: 95 I 1 29.5' 6 ai LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 2.5' OF STONE AROUND SIDES AND 2' AT ENDS (29.5' x 9.8' x 2' DEEP) SIDE AREA: (29.5'+ 9.81 x 2 x 2 = 157 SF (0.74) = 116 GAL/DAY BOTTOM AREA: 29.5'x 9.8'= 289 SF (0.74) = 214 GAL/DAY CAPACITY = 330 GAUDAY M19-14 • 'v� F ' ^0 112.0 0/A HORIZON LOAMY SAND 10YR 4/1 cQ ) 111.3 lth-1 BENCHMARK AT RIGHT CORNER OF BULKHEAD ELEVATION = 113.76 SEPTIC SYSTEM SECTION TION 111.43 1 /4" per ft 111.1 , ELEV. (2 PIPES, TO BE CONNECTED) 110.74 ELEV. 1500 GAL SEPTIC TANK PLUMBING CHANGE TO BE j6" OF STONE UNDER OR CONFIRMED PRIOR TO MECHANICALLY COMPACTED) CONSTRUCTION. TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN CONC. PATIO bh KITCHEN BED BED DINING ROOM ROOMLSATIHROOM PORCH ROOM ROOM EXISTING FLOOR PLAN Permit valid for REPAIR of; SEPTIC Str S•l'EM ONLY, idue to State and Local septic variances. Board orllealth review and approval is requircdi for any fgture additions/rends ations/akerations to sewage facilities and/or structures/dwelling. Yarmo6th Hcalth Qcpartnient \� 112: _ 112 D to o��@ts,OFMASS9cyGs TERRYINN F� ( WARNER N No. 38721 MAX -�-�._ COVER 1/8"per ft C MIN) ,49 = .,� 1 /8" per ft ELEV. ELEV. D -BOX (6" STONE UNDER) ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 4-25-19 PERCOLATION RATE: < 2 MIN/IN 2" PEASTONE OR FILTER FABRIC 3/4" -1 1/2" DOUBLE WASHED STONE - INSPECTION PORT �- ELEV.= 110.62 kal1°°° °°11 107.79 2 2 D. H , ELEV. 29.5'x 9.8' 3 - 500 GALLON CHAMBERS WITH 2.5' OF STONE AROUND SIDES AND 2' AT ENDS (29.5'x 9.8'x 2' EFF. DEPTH) TH-1 112.5 ELEV FILL ' 112.0 0/A HORIZON LOAMY SAND 10YR 4/1 111.3 B HORIZON LOAMY SAND 10YR 6/8 1 110-0 C HORIZON FINE -MED SAND 2.5Y 7/4 PERC AT 48" 136"1 1 101.2 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. j 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" & 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NE REPRESENT A FULL DETAILED PROPERTY SURVEY. FW�ITH IVED 13. EXISTING CESS POOL, DRY WELL AND LEACH PIT ARE TO BE PUMPED AND FSAND OR REMOVED. 1914. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. THE PROPOSED PLUMBING CHANGE IS TO BE CONFIRMED PRIOR TO CONST_,8 Jy.G LINE FROM THE KITCHEN IS UNDER THE 6" THICK CONCRETE PATIO. PERMITT"o-BE"OWFAI PRIOR TO CONSTRUCTION. THREE LINES INSIDE CESS POOL ARE ORANGEBERG PIPE. 16. THIS DESIGN REQUIRES THE APPROVAL OF A VARIANCE FROM TITLE 5: SECTION 15.211(1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE, (VARIANCE OF 1'). SITE PLAN r; MCLELLAM CIVIi _ Ao.3a471 MAS J. LOCATION: 8 MEADOWBROOK RD., W. YARMOUTH, MA PREPARED FOR: BILL GREEN DATE: 4-26-19 SCALE: i BASS RIVER ENGINEERING j P E P.O. BOX 1163, EAST DENNIS, MA 02641 j 508-364-9048