HomeMy WebLinkAboutReview Checklist 6-�it�i Q TOWN OF YARMOUTH
/ SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 3 ' Lot G Zone of Contribution: In Out creage
....------
i
Commercial: Residential:
Street:
Village: uj , 4_,v Floor Plan: #Bedrooms:
Owner: is g /i Installer: (//Z:
Address: Phone: 'NI . - srliraMIWIllr
Phone:
Builder: Engineer: �41/0..1
i � L
Address: Phone: _
Phone: .- A
IV/ AY. le. _,
` N/A YES NO _
1.Required#of copies received 4...------
2.Date of soils exam and percolation test not older than 2 years 1.-----
3. 4-5
----3. 4-5 ft of naturally occurring pervious material, above water table t...-.-
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
...._.---
5. Water line 10 ft from septic components Var.: L.---
6.Benchmark indicated and shown-NGVD if near wetlands 4.----
7. Septic tank minimum 10 ft from foundation, deck Var.: f..----
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t..---
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ..-------
11.
f11.Tank/leaching minimum 10 ft from property line Var.: L'-�
12. System meets all other setback requirements Var.: c....---
13. Uses adjustment for maximum high groundwater Var.: L-------
14.
_,e14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: t..._.-------
15.
��15. System not in top or subsoil(A,B horizons)or 5'removal �_-----'
16.Proposed contours are suitable L.-----
17.
_s17. System meets slope requirements-min. 1/8", 'A"preferred t_�
18. System meets breakout requirements PVC liner: Wall: (..---
19. Specified tee sizes are proper, gas baffle on outlet tee (-------
20.
/20. Sewage is under 10,000 gpd for parcel t f-
21.No garbage disposal t------
22. System adequately sized for its intended use t
23.Minimum 6"stone or compacted below tank and dbox �-
' 24.Manhole covers within 6"of grade,pump chamber cover to grade l..._...-----
25.
ei25. Inspection port on plastic chambers/leach field �,_.,..---•
26. Electrical permit for pump chamber/Separate meter for duplexes ��..
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size `__--•
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
%....._.--
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ..----'
33.H-20 loading is subject to vehicular traffic, groundwater .-------
34.
/34.Title V Application and permit fee, installer signature - ..------
35.Foundation footing min. 2 feet above adjusted ground water for new house e------
36.Deed Restriction required max. #bedrooms: max. flow: gpd ...-----'' -
37. Check area lots for groundwater/Label groundwater in Assessor's Map ,rte
Plan reviewed by: ( 6/03/03