HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH 4 �
SEWAGE PLAN REVIEW CHECKLIST . 2I t�x.4::
Location: A.M. 42Lot /b 2 Zone of Contribution: Inut Acreage a�7/
Street:
( ��L��G�/(.� ` Commercial: Residential: ��
Village: g-7- Y, Floor Plan: �� #Bedrooms: 2--
Owner: �� Installer: 7
Address: Phone:
Phone: l ,/ . (50 - k
Builder: Engineer: 2 ?-°'l G
"ti/
7
Address: Phone: 4ç ,,,
W
-- r
Phone: .r-/)t
/lilJ f/
N/A S )NO
1.Required# of copies received
2. Date of soils exam and percolation test not older than 2 years L.----
3.
i3. 4-5 ft of naturally occurring pervious material, above water table l.._-'
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L...-----
5. Water line 10 ft from septic components Var.: l�----
6.Benchmark indicated and shown-NGVD if near wetlands L---
7. Septic tank minimum 10 ft from foundation, deck Var.: _
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9
/.-- C:" e..--
9.Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: t/
12. System meets all other setback requirements Var.: _ L....----
13.
_�13.Uses adjustment for maximum high groundwater Var.: (..---
14.
e14.Leaching set 4-5 ft above adj.water or botto test-hb Var.: 1.�-+► ,
15. System not in top or subsoil(A,B horizons) r 5' remo L----'
16.Proposed contours are suitable t -----
17.
17. System meets slope requirements-min. 1/8", 1/4"preferredAA�� t...."'''18. System meets breakout requirements PVC liner:TO, . Tall: L...---
19. Specified tee sizes are proper, gas baffle on outlet tee Lem
20. Sewage is under 10,000 gpd for parcel 1.-------
21.
-O21.No garbage disposal C...----"'"
22. System adequately sized for its intended use L/
.23. Minimum 6"stone or compacted below tank and dbox
4.....----
24.
o24.Manhole covers within 6" of grade,pump chamber cover to grade L
25. Inspection port on plastic chambers/leach field , ,..---"'
26. Electrical permit for pump chamber/Separate meter for duplexes ✓'
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size ..-®-'
28. Septic tank/pump chamber to be factory waterproofed 1/4------
29.Vent provided if leaching below 3 feet, under driveway/parking l ��
30. Buoyancy calculations for tank/pump chamber `,.-----,
31. Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature c,_,_,--•
33. H-20 loading is subject to vehicular traffic, groundwater L-----"�
34. Title V Application and permit fee, installer signature -
35.Foundation footing min. 2 feet above adjusted ground water for new house .....----
36.Deed Restriction required max. #bedrooms: 2-max. flow: Z.->e gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map t.--------'
Plan reviewed by:
C---
6/03/03