Loading...
HomeMy WebLinkAboutReview Checklist ‘ fie'- (2 TOWN OF YARMOUTH Zt SEWAGE PLAN REVIEW CHECKLIST j Location: A.M. J Lot 23 Zone of Contribution: Inut Acreageg c----6 � ��� Commercial: Residential: c��'Street: Oeffit,Village: p � Floor Plan: #Bedrooms: Owner: J47J iz Installer: Address: Phone: Phone: ' Builder: 7 Engineer: 5"g J i- / / 7y - -j �� -- Address: Phone: , c--- 46-e,74 Phone: N/A NO 1.Required#of copies received �� 2.Date of soils exam and percolation test not older than 2 years t/ 3.4-5 ft of naturally occurring pervious material,above water table Z, 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: � 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: v 9.Leaching minimum 100 ft from wetlands Var.: 4.-__-- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ____---- 11.Tank/leaching minimum 10 ft from property line Var.: (___----- 12. System meets all other setback requirements Var.: .,.. 13.Uses adjustment for maximum high groundwater Var.: C------ 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal j l 16.Proposed contours are suitable „t.....-------- 17. ---`17. System meets slope requirements-min. 1/8", I "preferred t.----- 18. System meets breakout requirements PVC liner: Wall: (._..----- 19. ._.19. Specified tee sizes are proper, gas baffle on outlet tee ,�/� 20. Sewage is under 10,000 gpd for parcel -t/ 21.No garbage disposal E,,,.- 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox i------ 24.Manhole covers within 6"of grade,pump chamber cover to grade t_./" 72625.Inspection port on plastic chambers/leach field /7- 26. .Electrical permit for pump chamber/Separate meter for duplexes .,_. 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size �..-.r--' 28. Septic tank/pump chamber to be factory waterproofed ,_------- 29. __/29.Vent provided if leaching below 3 feet,under driveway/parking / f 30. Buoyancy calculations for tank/pump chamber ...,--1, 31. Engineer to inspect and certify soils: wall: commercial: . 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature0 33. H-20 loading is subject to vehicular traffic, groundwater •------* 34. Title V Application and permit fee, installer signature ' 35.Foundation footing min. 2 feet above adjusted ground water for new house c _-' 36.Deed Restriction required max. ' #bedrooms: T2-max. flow: 2 gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ��'',✓ 6/03/03