HomeMy WebLinkAboutReview Checklist ‘ fie'- (2 TOWN OF YARMOUTH Zt
SEWAGE PLAN REVIEW CHECKLIST j
Location: A.M. J Lot 23 Zone of Contribution: Inut Acreageg
c----6 � ��� Commercial: Residential: c��'Street: Oeffit,Village: p
� Floor Plan: #Bedrooms:
Owner: J47J iz Installer:
Address: Phone:
Phone: '
Builder: 7 Engineer: 5"g J i- / / 7y
- -j �� --
Address: Phone:
, c--- 46-e,74
Phone:
N/A NO
1.Required#of copies received ��
2.Date of soils exam and percolation test not older than 2 years t/
3.4-5 ft of naturally occurring pervious material,above water table Z,
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: �
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: v
9.Leaching minimum 100 ft from wetlands Var.: 4.-__--
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ____----
11.Tank/leaching minimum 10 ft from property line Var.: (___-----
12. System meets all other setback requirements Var.: .,..
13.Uses adjustment for maximum high groundwater Var.: C------
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5'removal j l
16.Proposed contours are suitable „t.....--------
17.
---`17. System meets slope requirements-min. 1/8", I "preferred t.-----
18. System meets breakout requirements PVC liner: Wall: (._..-----
19.
._.19. Specified tee sizes are proper, gas baffle on outlet tee ,�/�
20. Sewage is under 10,000 gpd for parcel -t/
21.No garbage disposal E,,,.-
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox i------
24.Manhole covers within 6"of grade,pump chamber cover to grade t_./"
72625.Inspection port on plastic chambers/leach field /7-
26.
.Electrical permit for pump chamber/Separate meter for duplexes .,_.
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size �..-.r--'
28. Septic tank/pump chamber to be factory waterproofed ,_-------
29.
__/29.Vent provided if leaching below 3 feet,under driveway/parking / f
30. Buoyancy calculations for tank/pump chamber ...,--1,
31. Engineer to inspect and certify soils: wall: commercial: .
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature0
33. H-20 loading is subject to vehicular traffic, groundwater •------*
34. Title V Application and permit fee, installer signature '
35.Foundation footing min. 2 feet above adjusted ground water for new house c _-'
36.Deed Restriction required max. ' #bedrooms: T2-max. flow: 2 gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ��'',✓ 6/03/03