Loading...
HomeMy WebLinkAboutInspection Report 2019 Jun 07 ,Jun 12 =2019 10:14 HP Fax page 1 c .\ Commonwealth of Massachusetts P 3 1'` JUN 17 2019 _ Title 5 Official Inspection Form HEALTH FT Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 3 117 Nottingham Drive i •;4. ;Ue 4 Property Address Jennie Lee Owner Owner's Name information is Yarmouthport MA 02675 6-7-19 required for every page. CitylTown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. `,,��>,%.KH OF fI► ri,��,' Important,When A. Inspector Information � '.... ''•`•cti• filling out forms `O: G on the computer, James D.Sears _,4-** �•. JAMES ..rt use only the tab -o: SEARS ' _ key to move your Name of Inspector 1* cursor-do not Capewide Enterprises ;..o o Q.a use the return p p ij,�FR l tWil�0‘6 ke . Company Name s •••• ..Q�G`�� y 153 Commercial Street "'•Otm,;imitst r"'� vre N Company Address \ Mashpee MA 02649 city fTown State Zip Code atm 508-477-8877 S1623 Telephone Number License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); I have personally inspected the sewage disposal system at the property address listed above;the information reported below is true, accurate and complete as of the time of my inspection;and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1. ❑ Passes 2. ® Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 6-11-19 pector's Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note:This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp doc.rev.T12612018 Title 5 Official Inspection Form.Subsurface Sewage Disposal system•Page 1 of 18 Jun 12. 2019 10:14 HP Fax page 2 Commonwealth of Massachusetts # Title 5 Official Inspection Form pi Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is required for y Yarmouth rt i-every Po MA 02675 6-7-19 page. City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3,or 5 and all of 4 and 6. 1) System Passes: 0 I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: Conn pass-D Box. The system is a 1500 Gal. Tank D Box and six chamber's. 2) System Conditionally Passes: CI One or more system components as described in the"Conditional Pass"section need to be replaced or repaired.The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined"(Y, N, ND)for the following statements. If"not determined,"please explain. The septic tank is metal and over 20 years old*or the septic tank (whether metal or not) is structurally unsound,exhibits substantial infiltration or exfrltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND(Explain below): t5insp.doc•rev.7126/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 Jun 12. 2019 10:14 HP Fax page 3 Commonwealth of Massachusetts Im_litt...r Title 5 Official Inspection Form .10_ Subsurface Sewage Disposal System Form -Not for Voluntary Assessments �l C: a - 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth required for every port MA 02675 6-7-19 page. City/Town State Zip Code, Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes(cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ® Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): ® distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): Need to replace 0 Box. ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): D broken pipe(a)are replaced ❑ Y 0 N 0 ND (Explain below): ❑ obstruction is removed 0 V 0 N E ND (Explain below): 3) Further Evaluation is Required by the Board of Health: O Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: t5irnp.doc•rev.7/26/2018 Title 5 prcaal Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18 •Jun 12 .2019 10:14 HP Fax page 4 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments , 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth rt MA 02675 6-7-19 required for every Yarmouthport City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health(and Public Water Supplier, If any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ��� Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7126/2018 Title 5 O1ctal Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18 ,Jun 12.2019 10:14 HP Fax page 5 Commonwealth of Massachusetts : Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth rt MA 02675 6-7-19 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ , Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in mos is less than 6"below invert or available volume is less than 1/2 day flow I£AcH,NC ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ e. Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ r Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis,performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ Ci The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the questions in Section C.4. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ 0 the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—1WPA)or a mapped Zone II of a public water supply well t8insp.doc•rev,7/26/2018 1tle 5 OfFicial Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18 •Jun 12 •2019 10:14 HP Fax page 6 • Commonwealth of Massachusetts **_ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments --:047 117 Nottingham Drive �"' Property Address Jennie Lee Owner owner's Name information is Yarmouthport MA 02675 6-7-19 required for every page, City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered"yes"to any question In Section C.5 the system is considered a significant threat, or answered"yes"to any question in Section C.4 above the large system has failed.The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section C.4 shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must Indicate"yes" or"no"for each of the following for all inspections: Yes No ❑ ® Pumping information was provided by the owner, occupant, or Board of Health O ® Were any of the system components pumped out in the previous two weeks? ❑ ® Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® 0 Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components,excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions,depth of liquid, depth of sludge and depth of scum? ❑ I7,4 Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: ® 0 Existing information. For example, a plan at the Board of Health. ❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(5)1 t51nsp.coc•rev.7!2612018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18 .Jun 12. 2019 10:14 HP Fax page 7 cLA Commonwealth of Massachusetts Title 5 Official Inspection Form 1' Subsurface Sewage Disposal System Form -Not for Voluntary Assessments k\._ c 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouthport MA 02675 6-7-19 required for every per, City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms(design): 6 Number of bedrooms(actual): 4 DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): 660 Description: 1500 Gal.Tank D Box and six chamber's. Number of current residents: 0 Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? E Yes ® No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonal use? D Yes ® No 28,000Ga1s Water meter readings, if available (last 2 ears usage(gpd)): 2018-106,OOOGaIs Detail: Sump pump? 0 Yes ® No Last date of occupancy: NA Dave t5inep-doe•rev.726/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18 ,Jun 12. 2019 10:14 HP Fax page 8 Commonwealth of Massachusetts -*v = Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 07 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information Is Yarmouth required for every port MA 02675 6-7-19 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft.,etc.): Grease trap present? ❑ Yes 0 No Water treatment unit present? ❑ Yes ❑ No If yes,discharges to: Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes 0 No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: NA Was system pumped as part of the inspection? 0 Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: tSlnsp.tloc•rev.7126/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18 .Jun 12► 2019 10:15 HP Fax page 9 Commonwealth of Massachusetts ` Title` 5 Official Inspection Form Subsurface7.74.1i.m.. . Sewage Disposal System Form -Not for Voluntary Assessments r It , . ...._.,. 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information a every Yarmouth ort required for eve __ MA 02675 6-7-19 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: ® Septic tank,distribution box, soil absorption system ❑ Single cesspool O Overflow cesspool ❑ Privy 0 Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology.Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank.Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed(If known)and source of information: 2001 Permit # 00-593. Were sewage odors detected when arriving at the site? 0 Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: feet et Material of construction: ❑cast iron ®40 PVC 0 other(explain): Distance from private water supply well or suction line: feet Comments(on condition of joints, venting, evidence of leakage, etc.): Pipeing is 4"PVC SCH -40. t5 nsp.doc•rev.71282818 Title 5 Oficial Inspection Form:Subsurface SewageDisposal iaF osal System•Page 9 of 18 Jun 12. 2019 10:15 HP Fax page 10 Commonwealth of Massachusetts x= p Title 5 Official Ins Inspection Form ' =-.7.w - Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth ort MA 02675 6-7-19 required for every Yarmouthport City/Town State Zip Code Date of Inspection D. System Information (cont) 6. Septic Tank(locate on site plan): 42" Depth below grade: feet Material of construction: ®concrete ❑ metal E fiberglass ❑ polyethylene ❑other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes 0 No Dimensions: 1500 Gal. Precast H-10 2" Sludge depth: Distance from top of sludge to bottom of outlet tee or baffle 28" 0" Scum thickness Distance from top of scum to top of outlet tee or baffle 8" Distance from bottom of scum to bottom of outlet tee or baffle 18" How were dimensions determined? Asbuilt-Tape Sludge Judge Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank at working level.Tank at 42"belw grade w/inlet cover at 13" and outlet cover at 20. In and outlet tee's. No sign of leakage or over loading. t5lnsp.doc-rev.7/26/2018 Title 5 Official inspection Form Slbsudace Sewage Disposal System'Page 10 of 18 , Jun 12. 2019 10:15 HP Fax page 11 Commonwealth of Massachusetts *. Title 5 Official Inspection Form _* ., Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth required far everyport MA 02675 6-7-19 page. City/Town State Zip Code Dare of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑concrete ❑ metal D fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments(on pumping recommendations, inlet and outlet tee or baffle condition,structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑metal ❑fiberglass 0 polyethylene 0 other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc•rev.712612018 Tile 5 Official Inspeclion Form:Subsurface Sewage Disposal System•Page 11 of 16 ,Jun 12; 2019 10:15 HP Fax page 12 ` , Commonwealth of Massachusetts 1,0-*-_-„ 1 Title 5 Official Inspection Form =_vw= Subsurface Sewage Disposal System Form-Not for Voluntary Assessments ''�.1' 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth ort MA 02675 6-7-19 required for every p page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 5. Tight or Holding Tank(cont.) Alarm present: ❑ Yes E No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments(condition of alarm and float switches,etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0 Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): D Box is 16"x16"-4'below grade w/three line's out. Inlet tee. Need to replace Box. t5insp.doc•rev.7/26/2018 Title 9 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 18 ,Jun 12, 2019 10:15 HP Fax page 13 Commonwealth of Massachusetts ..,_=-„-411-----, , . Title 5 Official Inspection Form __.! _ ‘A Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,, -, 117 Nottingham Drive . r Property Address Jennie Lee Owner Owner's Name information Is Yarmouthport MA 02675 6-7-19 required for every page. City/Town State Zlp Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances,etc.): * If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System(SAS)(locate on site plan, excavation not required): If SAS not located, explain why: Type: ❑ leaching pits number: ® leaching chambers number: 6 ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: O overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp doe•rev.T/2812018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of Se , Jun 12. 2019 10:15 HP Fax page 14 Commonwealth of Massachusetts '��1►- Title 5 Official Inspection Form T Subsurface Sewage Disposal System Form Not for Voluntary Assessments N. ,,, 117 Nottingham Drive Property Address Jennie Lee Owner Owners Name information is Yarmouthport MA 02675 6-7-19 requirec for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS)(cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding,damp soil,condition of vegetation,etc.): Leaching is six 500 Gal.Dry well chamber's. Chamber's at 40"below grade w/cover at 10". Chamber's are clean-dry-like new. 12. Cesspools(cesspool must be pumped as part of inspection)(locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Tide 5 Official Inspection Farm Subsurface Sewage Disposal System•Page 14 of 16 , Jun 12. 2019 10:16 HP Fax page 15 • Commonwealth of Massachusetts M Title 5 Official Inspection Form • *_ Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouthport MA 02675 6-7-19 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy(locate on site plan): Materials of construction: Dimensions Depth of solids Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.dac•rev.7126/2018 Title 5 OM dal Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18 Jun 12= 2019 10:16 HP Fax page 16 c , Commonwealth of Massachusetts ga' ,, P Title 5 Official Inspection Form I Subsurface Sewage Disposal System Form - Not for Voluntary Assessments . 117 Nottingham Drive Property Address Jennie Lee Owner Owners Name information is required for every Yarmouthport MA 02675 6-7-19 page. CitylTown State Zip Code Date of Inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: 40 hand-sketch in the area below ❑ drawing attached separately l5insp.dcc•rev.7126/2018 Tide 5 Offidal Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18 page 17 , Jun 12= 2019 10:16 HP Fax IJ iToN kt, Pis ti\mee-clIoN1 Oto (07f(5 c -P SDE- W ‘)(u5eS , /J17'1,47/4'519 LOT NO. 3 ./ ADDRESS: d OWNERS NAME: $EtrAGE PERMIT NO. : `S NE{�1: � �EtEpAIR: DATE xSSUED: .. •.-.` -. ODATE IttSTAI.LED: INSTALLERS NAMEk'z INSTALLATION OF: .-. ( _ Wia'ATER TADLE: / "FINAL INSPECTION $Y: ,i/' 4'y DRAWING OF .INSTALLATION ON REVERSE SIDE: • 1.\\ 114\N £'d 116tr-LL17•909 sesiidiejuE ep!MedeO e££ l L'6t 6Z Aim ,Jun 12. 2019 10:16 HP Fax page 18 , Commonwealth of Massachusetts * _ Title 5 Official Inspection Form .I_ tb Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ''4,. -= 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information is Yarmouth rt required for every port MA 02675 6-7-19 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ❑ Check Slope O Surface water O Check cellar El Shallow wells Estimated depth to high ground water: 10 feet Please indicate all methods used to determine the high ground water elevation: ® Obtained from system design plans on record If checked,dale of design plan reviewed: 2000 Date O Observed site(abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health-explain: ❑ Checked with local excavators, installers- (attach documentation) El Accessed USGS database -explain: You must describe how you established the high ground water elevation: T.H. on Design plan 2000- 10' no G.W.. Bottom of chamber's at 6' below grade. Bottom of chamber's at 4'above T.H. Depth. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc'rev.7/26f2018 Title 5 Olidal Inepecton Form:Subsurface Sewage Disposal System•Page 17 of 18 Jun 1? 2019 10:16 HP Fax page 19 Commonwealth of Massachusetts > F Title 5 Official Inspection Form L ) y ^ Subsurface Sewage Disposal System Form-Not for Voluntary Assessments > - 117 Nottingham Drive Property Address Jennie Lee Owner Owner's Name information Is Yarmouthport MA 02675 6-7-19 required for every page. Cityrrown State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form Inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B.Certification: Signed&Dated and 1, 2, 3, or4 checked ® C. Inspection Summary: 1,2, 3, or 5 completed as appropriate 4 (Failure Criteria)and 6 (Checklist)completed .1 D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14:Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included i5insp.doc.rev.7/2612016 Tills 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 18 0118