Loading...
HomeMy WebLinkAboutEngineered Plan - 2019CAPT BEgSE RD KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ............. _OCUS EXISTING SPOT ELEVATION: 25.5 C) C1 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: + UTILITY POLE: -O- `am FENCE LINE: r HYDRANT: N N S RETAINING WALL: 4 ��p p t7 LOCATION MAP 40.0' LOT 446 (11,220 SF)��'- ASSESSORS MAP: 67 PARCEL: 139 ml I 1 PLAN BOOK: 249, PAGE: 113 LEACH AREA DETAIL oak M19-16 Shed N yoak _.. 100 6 9, s s. r, t' `i i, 101 B' t ST 24" oak ew tii sep t �r l� %` LIP r 24" JJ oak ,J J J J ___e of Lawn _ ,Edg- ; - toc ade Fence L 100 101 E SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 4 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' DEEP) WITH 1' OF STONE ALL AROUND SIDES AND TAT ENDS (40'x 6.8'x 2' DEEP) SIDE AREA: (40' + 6.8') x 2 x 2 = 187 SF (0.74) = 138 GAUDAY BOTTOM AREA: 40'x 6.8'= 272 SF (0.74) = 201 GAUDAY CAPACITY = 339 GAL/DAY i cz m �, PAVED DRIVE GARAGE `w slab W full basement DECK 6 ig 101 sh w EXISTINGOM 3 BEDRO og InWG d =102.46 bb BENCHMARK AT LEFT CORNER OF WOOD BULKHEAD ELEVATION = 101.54 110.00' " g 80°3520 W 101 GARAGE FAMILY ROOM SEPTIC SYSTEM SECTION TION .EV. 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" U 13" DOWN OUTLET: 6" UP, 14" DOWN ROOM I ROOM ROOM rte, - AREA BATH BED ROOM KITCHEN I _I I show bh DECK EXISTING FLOOR PLAN k -n MAX. 1/8" per ft (1„ COVER (1' MIN) 19.2 1 /8" r�er ft LEV, - 8.5 ELEV. ELEV. D -BOX (6"STONE UNDER) ELEV, -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 4-26-19 PERCOLATION RATE: < 2 MIN/IN USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: A, ADJ. (MARCH): 0.7 ADJUSTED GROUND WATER ELEV.= 91.2 NOTES: 2" PEASTONE OR FILTER FABRIC - 3/4"-1 1/2" DOUBLE WASHED STONE INSPECTION PORT i- ELEV.= 99.13 LA01 1 . . . . . . . . . . . 1-1 96.3 96 3 1- ELEV. 40'x 6.8' 4 - 500 GALLON CHAMBERS WITH 5.1' l' OF STONE AROUND SIDES AND 3' AT ENDS (40'x 6.8'x 2' DEEP) ADJUSTED GROUND WATER ELEVATION = 91.2 %A.AA j.✓ TH-1 ,,,,, g,, FILL 0/A HORIZON LOAMY SAND 18" 10YR 4/1 y 0 B HORIZON LOAMY SAND 30" 10YR 5/8 98.0 C HORIZON MEDIUM SAND 2.5Y 7/4 • pER,G.AT 4A" - 120" . OBSERVED . , 1 , 90.5 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL, 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. THIS DESIGN REQUIRES THE APPROVAL OF A VARIANCE FROM TITLE 5. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE, (VARIANCE OF 3'). SITE PLAN i LOCATION: 17 CAPT. WEILER RD.. S. YARMOUTH. MA PREPARED FOR: JOHN PULEO SCALE: 1" = 20' ) BASS RIVER ENGINEERING THOMAS J. McL AN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048