HomeMy WebLinkAboutReview Checklist I---)-4*-7,7 TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot ZZ Zone of Contribution: In Out( creage Commercial: Residential: '- Street: �f( CGYG /t!c$ Village: t.4. ik Floor Plan: #Bedrooms: -"2--- Owner: _Owner: ZiodE'Citji? Installer: A'17.--Ve..--7 Address: Phone: - f d7- 7/S'5 Phone: bhry" £ 4 ,00-‘azAe ‘ii• Builder: Engineer: G Address: Phone: G d" if T'-5--/9 Phone: , y/L S- o,�4 C-/. cavi//Coire/ /3� A)7i -e .-7`..S 1,> N/A YES NO / 1.Required# of copies received L.----- _ 2. Date of soils exam and percolation test not older than 2 years L...--- 3. 3. 4-5 ft of naturally occurring pervious material, above water table v- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t_ --:- 5. 5. Water line 10 ft from septic components Var.: (---- 6. -/6.Benchmark indicated and shown-NGVD if near wetlands c......---- 7. �7. Septic tank minimum 10 ft from foundation, deck Var.: ,_•,i- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: k..-- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 3' ( )) c___.- 12. ___.12. System meets all other setback requirements Var.: 1------- 13. Uses adjustment for maximum high groundwater Var.: k.i• 14. Leaching set 4-5 ft above adj.water or botto st-hole Var.: L--. 15. System not in top or subsoil(A,B horizons) or 5'removal\ 16.Proposed contours are suitable t:' ---'7 7 17. S stem meets sloe re•uirements-min. 1/8", 1/4" . eferred 18. System meets breakout requirements PVC liner: ,fall: 19. Specified tee sizes are proper, gas baffle on outlet tee Li• 20. Sewage is under 10,000 gpd for parcel lam" 21.No garbage disposal l•---- 22. System adequately sized for its intended use l----- 23. •/23. Minimum 6" stone or compacted below tank and dbox 1/4---- 24.Manhole covers within 6"of grade,pump chamber cover to grade o„,----- 25. „125. Inspection port on plastic chambers/leach field k.----• 26. Electrical permit for pump chamber/Separate meter for duplexes L----' 27.Pump system-2"line,weep hole,check valve,tee in dbox, pump size `----' 28. Septic tank/pump chamber to be factory waterproofed L.----- 29. Vent provided if leaching below 3 feet, under driveway/parking �2--) 30. Buoyancy calculations for tank/pump chamber �---- 31. Engineer to inspect and certify soils: wall: commercial: ✓ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature Lam' 33.H-20 loading is subject to vehicular traffic, groundwater l----. 34.Title V Application and permit fee, installer signature - ( _) 35.Foundation footing min. 2 feet above adjusted ground water for new house `-f 36. Deed Restriction required max. #bedrooms: max. flow: gpd ' -----' 37. Check area lots for groundwater/Label groundwater in Assessor's Mapn �_J Plan reviewed by: (t(�J eiO3iO3