Loading...
HomeMy WebLinkAboutReview Checklist , TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST • Location: A.M. Lot 7t 3 Zone of Contribution: In Out Acreage Commercial: Residential: Street: 2- mm Village: > 0Floor Pl. i: . :edrooms g z3 'Pei/ Owner: >,' 17/(4 ' Installer: Address: Phone: lit/ n is -7/0 - 6 Phone: Ail gepeg �' Builder: Engineer: �� �J Address: Phone: �"'j ' ``' Phone: /l/ �tt�G / . �,� QHS/�� p/tat(iik, N6 1.Required#of copies received C � 2.Date of soils exam and percolation test not older than 2 years L---' 3.4-5 ft of naturally occurring pervious material,above water table L_-. 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L---. 5.Water line 10 ft from septic components Var.: (._--- 6.Benchmark indicated and shown-NGVD if near wetlands (._am- _ 7. Septic tank minimum 10 ft from foundation, deck Var.: L..----' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t...----- 9. /9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: t.---- 12.System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 6,1r C-.), (-- 14.Leaching set 4-5 ft above adj.water or bottom o o e ar.: c_..--- 15. System not in top or subsoil(A,B horizons)o 5'remov 16.Proposed contours are suitable L/ 17. System meets slope requirements-min. 1/8", '/4' preferred (� 18. System meets breakout requirements PVC liner: Wall: �� 19. Specified tee sizes are proper, gas baffle on outlet tee ti' - 20. Sewage is under 10,000 gpd for parcel Lf 21.No garbage disposal L----"" 22. System adequately sized for its intended use `./ ` 23.Minimum 6"stone or compacted below tank and dbox 1/4.----- 24.Manhole covers within 6"of grade,pump chamber cover to grade •.---- 25.Inspection port on plastic chambers/leach field c._-s 26.Electrical permit for pump chamber/Separate meter for duplexes ---- 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed ------ . 29.Vent provided if leaching below 3 feet,under driveway/parking ..------ 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ...----- 32. 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater _ 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 1�,----" 36.Deed Restriction required max. #bedrooms: max. flow: gpd _ �, 37.Check area lots for groundwater/Label groundwater in Assessor's M. . L...� IPlan reviewed by: 6/03/03