Loading...
HomeMy WebLinkAboutEngineered Plan - 2018LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. THry�1, 4. DESIGN LOADING FOR SEPTIC TANK AND PUMP CHAMBER {} TEST HOLE 2�a- SLOPE OF GROUND Q) UTILITY POLE THICKNESS REQUIRED I FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM EXIST. PIER, RAMP & FLOAT INTERIM APPROVAL # 7228 DATED 12/1997 FIRST FL EL. 41.5' SYSTEM PROFILE ALL .Y TEM COMPONENTS SHALL BE NOTES MARK\ OR TOP FOUND. EL. 40.3' COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) 1. DATUM IS NAVD 88 c:= ACCESS COVERS TO WITHIN 6" OF FIN. GRADE-CONCRETE O 2" PEASTONE OR GEOTEXTILE (OR C.I. COVERS RWITHIN TO ADEGRADE F UNDER DRIVEWAY) 2. MUNICIPAL WATER IS EXISTING FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 40.0' 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. BASE. SLAB ELEV. 31.5' •y f. >1• ±28.7'/ I (2 % SLOPE) FOUNDATION- 13' ST FOLLINS POND ADD CANTILEVERED RACKS (TIDAL) FOR KAYAK STORAGE (TYP) BOTH SIDES ROCKY 1NTERT/DAL SERC pp TOE OF C• BANK FN SCHO.BROS. CJS FN- I UG V / V�TANK (R MOVE) O v < _V�2� 27 28- o ' �31 PAVER (REMOVE) 10 REMOVE '�T/)TiTf�•jTfrT� 1t/-LJJ r � . E(REMDWELL . PROP: q5qO GAL. SEPTIC TANK PRO GAL. PC °? 3/4"-1-1/2" DOUBLE WASHED STONE H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (4) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED _ 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 39.0' X 10.8 F PERMISSION OBTAINED F3' WITHOUT INSPECTION BOARD OF HEALTH AND COMPACTION. (15.221 [21) ROM BOARD OF HEALTH. J. FERRARI, SE �a .y a cc. 32' NOTE: 2" MIN. WALL / Follins Locus 4. DESIGN LOADING FOR SEPTIC TANK AND PUMP CHAMBER (1 % SLOPE) O PRECAST H-10 �Gf SOILS 29.0' BOTTOM TH-1 THICKNESS REQUIRED I E�• �� Stoney Hill ROG o 7 0» BLOCKS OR 42.0' TO BE AASHO H-� LEACHING FACILITY TO BE H-20 SCALE 1"=2000'± (o RISERS (TYP.) 2'0 a LS 4"4SCH40 PVC LEACHING FACILITY. ASSESSORS MAP 127 PARCEL 65 PUMP 108' D' BOX PRECAST RISERS MORTAR ALL H-20 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND 5. PIPE JOINTS TO BE MADE WATERTIGHT. 8' CHAMBER 21 FACILITY REMOVED. AE EL. 9 MIN. SUMPIES DATUM: NAVD '88 cCOMPONENTSP P /�L 1ST 2'6" Le1.: ENDS....... HANDLE ALL ROOF RUN-OFF (OR ROOF DRIPLINES TO STONE 500 GAL.+ TYP.INV'S EL. 36.17'12" TRENCHES). - SITE DOES NOT LIE WITHIN ZONE 11 TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP 14. ALL RUN-OFF TO BE DIRECTED AWAY FROM FOUNDATION SITE DOES NOT LIE WITHIN PRIORITY/ESTIMATED HABITAT BUILDING. ALARM TO BE ON MIN. INT._ DIM. _\j; SEPARATE CIRCUIT FROM PUMP _____ _ __ ____ _ __ ____ _ __ SIDES 37.17 _ 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE--WITH10" 14" :y m VALVE °°°°°°°° MIN. FRONT SETBACK 3Q� ' °310 CMR 15.000 (TITLE 5.) TEE 1500 GAL H-10 TEE TANK 28.15' Q PROP. TEE '. MYERS WHRH** o 0 0 0 ®������� �����®0000®00�®®®®�0 0 o o a> E��O� --�®®O 0 0 0° OOOOSEPTIC 'o°o°o°o° o 0 0 04' o°o°o o '0°0°0°0° LIO. LEVEL GAS BAFF o o0 0 0 or ' °0°00000000a WATERTE.aT D BOX - 0 0 0„0 0_ o N ,°o°o°o°o o 0 0 0ACME ��0��®��®®� ®��0�00��®� '0o°o°o°0 o°°O°°O°°O°BE 7..THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO USED FOR LOT LINE STAKING OR ANY OTHER OR EQUAL SYSTEM (OR EQUAL) °�� FOR LEVELNESS >°°°°°000a °°°°°°°°a®�oo��000a o o o 0 0 0 .°°°°°°°° 36.53' 36.36�� >°�°�°0°0 ' .°°°°°°O° ° ° ° ° 34.17' PURPOSE. COMPACTION. (15.221 [21) - Pump CHAMBER **NOTE: SPECIAL HIGH HEAD BOTTOM 39 X 10.83 (.7.4) = 312.5 GPD OWNER OF RECORD 8 PIPE FOR SEPTIC SYSTEM TO SCH 40-4" PVC I (2 % SLOPE) FOUNDATION- 13' ST FOLLINS POND ADD CANTILEVERED RACKS (TIDAL) FOR KAYAK STORAGE (TYP) BOTH SIDES ROCKY 1NTERT/DAL SERC pp TOE OF C• BANK FN SCHO.BROS. CJS FN- I UG V / V�TANK (R MOVE) O v < _V�2� 27 28- o ' �31 PAVER (REMOVE) 10 REMOVE '�T/)TiTf�•jTfrT� 1t/-LJJ r � . E(REMDWELL . PROP: q5qO GAL. SEPTIC TANK PRO GAL. PC °? 3/4"-1-1/2" DOUBLE WASHED STONE H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (4) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED _ 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 39.0' X 10.8 F PERMISSION OBTAINED F3' WITHOUT INSPECTION BOARD OF HEALTH AND COMPACTION. (15.221 [21) ROM BOARD OF HEALTH. FLOODZONE AE EL. 9 21 22 / 2� 24 26� lop aft P. 2� � 29 I/ 1 N �. 36,\ 56 O O O EXIST. �_\ 1500 GAL. ST -34-- �5 Q PROP. 3 39 GARAGE >� (SLAB) .: k 20 j' j 40.5' P ' ' PROP.-.SHELL/G. AVS L-.:. UP D .,..-DRIVEWAY • :'�:' O 3TH $ 39 RO3 SWALE 1 39: o 1/-- , 4. !M �V X RESERVE 4� y HIGH PT. 43.0' ;' -�� j I •v,. BOULDER VARIANCE REQUESTS TOP OF FOUNDAI TO BE 2.5' BELOW IGH PT. CONC. 171.38' IN ROAD (4.5' VARIANCE) BND FN D. �: -40 { 5' REMOVAL OF UNSUITABLE SOIL REQUIRED BENCHMARK: CONC. BOUND AROUND PORTION OF PERIMETER OF LEACHING AT EL. 38.4' FACILITY, TOLA REPLACE WITHNCLEEANUMED. LSANOD, TOYMEET DRIFTWOOD LANE C SPECIFICATIONS OF 310 CMR 15.255(3). off 508-362-4541 I fox 508-362-9880 downcape.com MIO cape e4&Pri4eeri7,fs Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 117-413 LOT 11 0.95± AC J. FERRARI, SE �a .y a cc. 32' 0 / Follins Locus Pond (1 % SLOPE) O OF ALL: UNDERGROUND & PRIOR LOCATIOTO COMMENCEMENT OF WORK_OVERHEAD UTILITIES �Gf SOILS 29.0' BOTTOM TH-1 , rvo °p, E�• �� Stoney Hill ROG o 7 0» NO GROUNDWATER FOUND11. 42.0' o SCALE 1"=2000'± (o A a LS Knob Hill LEACHING FACILITY. ASSESSORS MAP 127 PARCEL 65 FLOODZONE AE EL. 9 21 22 / 2� 24 26� lop aft P. 2� � 29 I/ 1 N �. 36,\ 56 O O O EXIST. �_\ 1500 GAL. ST -34-- �5 Q PROP. 3 39 GARAGE >� (SLAB) .: k 20 j' j 40.5' P ' ' PROP.-.SHELL/G. AVS L-.:. UP D .,..-DRIVEWAY • :'�:' O 3TH $ 39 RO3 SWALE 1 39: o 1/-- , 4. !M �V X RESERVE 4� y HIGH PT. 43.0' ;' -�� j I •v,. BOULDER VARIANCE REQUESTS TOP OF FOUNDAI TO BE 2.5' BELOW IGH PT. CONC. 171.38' IN ROAD (4.5' VARIANCE) BND FN D. �: -40 { 5' REMOVAL OF UNSUITABLE SOIL REQUIRED BENCHMARK: CONC. BOUND AROUND PORTION OF PERIMETER OF LEACHING AT EL. 38.4' FACILITY, TOLA REPLACE WITHNCLEEANUMED. LSANOD, TOYMEET DRIFTWOOD LANE C SPECIFICATIONS OF 310 CMR 15.255(3). off 508-362-4541 I fox 508-362-9880 downcape.com MIO cape e4&Pri4eeri7,fs Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 117-413 LOT 11 0.95± AC J. FERRARI, SE i #13871 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING WITNESS: PHIL RENAUD 32' DATE: 12/20/17 DIGSAFE (1-888-344-7233) AND VERIFYING THE 1 •8 (-L8-% SLOPE) (1 % SLOPE) OF ALL: UNDERGROUND & PRIOR LOCATIOTO COMMENCEMENT OF WORK_OVERHEAD UTILITIES LOCUS MAP SOILS 29.0' BOTTOM TH-1 SYSTEM DESIGN: ZONING SUMMARY ELEV. 0» NO GROUNDWATER FOUND11. 42.0' ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE SCALE 1"=2000'± A REMOVED BENEATH AND 5' AROUND THE PROPOSED LS INV. IN 28.0' LEACHING FACILITY. ASSESSORS MAP 127 PARCEL 65 PUMP 108' D' BOX LEACHING 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND LOCUS IS WITHIN FEMA FLOOD ZONE X & 8' CHAMBER 21 FACILITY REMOVED. AE EL. 9 13. DOWNSPOUTS TO DRYWELLS SHALL BE PROVIDED TO DATUM: NAVD '88 PROP. WATERTIGHT COVER TO GRADE HANDLE ALL ROOF RUN-OFF (OR ROOF DRIPLINES TO STONE 500 GAL.+ ALARM AND CONTROL PANEL TRENCHES). - SITE DOES NOT LIE WITHIN ZONE 11 TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP 14. ALL RUN-OFF TO BE DIRECTED AWAY FROM FOUNDATION SITE DOES NOT LIE WITHIN PRIORITY/ESTIMATED HABITAT BUILDING. ALARM TO BE ON RESERVE SEPARATE CIRCUIT FROM PUMP USE A 440 GPD DESIGN FLOW MIN. LOT FRONTAGE 150' 15. ELECTRICAL PERMIT REQUIRED. PUMP ONCHECK FLOODZONE AE EL. 9 21 22 / 2� 24 26� lop aft P. 2� � 29 I/ 1 N �. 36,\ 56 O O O EXIST. �_\ 1500 GAL. ST -34-- �5 Q PROP. 3 39 GARAGE >� (SLAB) .: k 20 j' j 40.5' P ' ' PROP.-.SHELL/G. AVS L-.:. UP D .,..-DRIVEWAY • :'�:' O 3TH $ 39 RO3 SWALE 1 39: o 1/-- , 4. !M �V X RESERVE 4� y HIGH PT. 43.0' ;' -�� j I •v,. BOULDER VARIANCE REQUESTS TOP OF FOUNDAI TO BE 2.5' BELOW IGH PT. CONC. 171.38' IN ROAD (4.5' VARIANCE) BND FN D. �: -40 { 5' REMOVAL OF UNSUITABLE SOIL REQUIRED BENCHMARK: CONC. BOUND AROUND PORTION OF PERIMETER OF LEACHING AT EL. 38.4' FACILITY, TOLA REPLACE WITHNCLEEANUMED. LSANOD, TOYMEET DRIFTWOOD LANE C SPECIFICATIONS OF 310 CMR 15.255(3). off 508-362-4541 I fox 508-362-9880 downcape.com MIO cape e4&Pri4eeri7,fs Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 117-413 LOT 11 0.95± AC � WORK LIMIT LINE TO CONSIST OF STAKED SILT FENCE BACKED BY STAKED COIR LOGS / _/t -PUMP AND REMOVE 1.1 EXISTING SEPTIC SYSTEM PROP. 4 BR DWELL. TOP FNDN. = 40.3' FIRST FL. = 41.5' TOP OF STEM WALL = 41.3' BASEMENT SLAB ELEV. 31.5' r_j� I PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTACTOR WITH HOMEOWNER CONSULTATION) ��BND FN ENGINEER: CRAIG J. FERRARI, SE i #13871 WITNESS: PHIL RENAUD 32' DATE: 12/20/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS SYSTEM DESIGN: ZONING SUMMARY ELEV. 0» 40' 0" 42.0' A A LS INV. IN 28.0' LS 2" PRESSURE LINE SCH. 40 GARBAGE DISPOSER IS NOT ALLOWED ZONING DISTRICT: R-40 DISTRICT 1OYR 4/2, 1000 GAL. H-10 S/T 6" B B 500 GAL.+ LS SLOPE TO DRAIN BACK TO PC 20 GALLON DRAIN BACK MAX. DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD MIN. LOT SIZE 40,000 S.F. FLOAT SWITCH ALARM ON 1 OYR 5/6 39.5' RESERVE 0.25" WEEP HOLES USE A 440 GPD DESIGN FLOW MIN. LOT FRONTAGE 150' SETTINGS: PUMP ONCHECK 5" VALVE MIN. FRONT SETBACK 3Q� 5.3" WORKING RANGE MYERS WHRH** SEPTIC TANK: 440 GPD (2) = 880 MIN. SIDE SETBACK 20 5.3" SUBMERSIBLE 1/2 HP PUMP USE A 1500 GAL. SEPTIC TANK MIN. REAR SETBACK 20' PUMP OFF 12" SYSTEM (OR EQUAL) USE A 1000 GAL. PUMP CHAMBER CONTAINING MYERS WHRH 1.5 HP PUMP 000 00000 O o 000000 pOC;�O O O O 0000 6" CRUSHED STONE OR MECHANICAL LEACHING: COMPACTION. (15.221 [21) SIDES2 (39 + 10.83) 2 (.74) = 147.5 GPD Pump CHAMBER **NOTE: SPECIAL HIGH HEAD BOTTOM 39 X 10.83 (.7.4) = 312.5 GPD OWNER OF RECORD (NOT TO SCALE) IMPELLER ON PUMP MANDATORY TOTAL: 621.6 S.F. 460 GPD ROBERT & BONNIE McNAMARA WATERPROOF/WATERTIGHT USE (4) 500 GAL. H-20 LEACHING CHAMBERS (ACME OR EQUAL) 982 OENOKE RIDGE RD. WITH 2.5' STONE AT ENDS AND 3' AT SIDES NEW CANAAN, CT 06840 REFERENCES MA APPROVED DATE BOARD OFA/HEALTHDE ED BOOK 30740 PAGE 163 - -� - LGP 21033-A" L T 11 0 -J SEPTIC INSPECTION REPORT/AS-BUILT D. 8/21/2017 (3 BEDROOM SYSTEM) j I TEST HOLE LOGS � WORK LIMIT LINE TO CONSIST OF STAKED SILT FENCE BACKED BY STAKED COIR LOGS / _/t -PUMP AND REMOVE 1.1 EXISTING SEPTIC SYSTEM PROP. 4 BR DWELL. TOP FNDN. = 40.3' FIRST FL. = 41.5' TOP OF STEM WALL = 41.3' BASEMENT SLAB ELEV. 31.5' r_j� I PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTACTOR WITH HOMEOWNER CONSULTATION) ��BND FN ENGINEER: CRAIG J. FERRARI, SE i #13871 WITNESS: PHIL RENAUD DATE: 12/20/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. \ ELEV. 0» 40' 0" 42.0' A A LS LS 1OYR 4/3 1OYR 4/2, 10" 6" B B LS LS 45" 1 OYR 5/8 36.25* 301) 1 OYR 5/6 39.5' Yarn ®uth HealtL Departrl eut ozl��'z - - z/p� Aare Date C C PERC ®ss" TITLE 5 SITE PLA TIGHT IN PLACE MS ROCKY POCKETS MS OF 10YR 7/4 10YR 7/4 82 DRIFTWOOD LANE SOUTH YAR OUTH 132" J 29.0' 132" 31.0' NO GROUNDWATER ENCOUNTERED OF P.1"j ' �y �•i�'�N rz+ t1�I�IIEL `G�\ DANIEL JAls R. OJALA « >'65v2 I ,a J'�t;0 ry No. 40980\oma' .�sss �a�ES \off Q al>e 4S f STE�� �A yni� SUR�Ev� DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR MARCH 8, 2018 Scale:1 "= 20' 0 10 20 30 40 50 FEET 17-413 MCNAMARA RECOVER recover.DWG