HomeMy WebLinkAboutReview Checklist Irkl---2-÷7 Q
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /2-7 Lot o. Zone of Contribution: In Out `."----Acreage
�� � �/��� Commercial: Residential: N/"�
Street:
Village: 40" Floor Plan: L./- #Bedrooms: '9
Owner: it('"%ilfai-44_ Installer: 7 %Li* /1-3 - .0 Phone:
Phone: L--2e ty 'e ,at
Builder: 7Engineer: h-124,/,1 / l
Address: / Phone: - -
Phone: I - < 4,1 ,7 /1".'"L,',
trt, - j,, ' ,:i ems' 7/477'0-4,7
-(542 '7 IST/A YE NO
/ 1.Required#of copies received C
2.Date of soils exam and percolation test not older than 2 years LY
3.4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road �J"�/C�H.F... Fnd: 4
Tar.: c
ti----
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands t,-----"
7. Septic tank minimum 10 ft from foundation, deck Var.: --
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �----"
9.Leaching minimum 100 ft from wetlands Var.: �:/-
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: (.....---
11.Tank/leaching minimum 10 ft from property line Var.: ....-----
12. System meets all other setback requirements Var.: l..-- -'
13.Uses adjustment for maximum high groundwater Var.: .
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: .--
15. System not in top or subsoil(A,B horizons)or 5'fomovaav` %.....-------
16.
r----
16.Proposed contours are suitable t...---
17.
�,17. System meets slope requirements-min. 1/8", 1/4"preferred (_.----
18. System meets breakout requirements PVC liner: Wall: L-------
19.
-/19. Specified tee sizes are proper, gas baffle on outlet tee %.-------
20.
.-/20. Sewage is under 10,000 gpd for parcel u--
21.No garbage disposal 1/4.-------
22.
✓22. System adequately sized for its intended use L...-----
23.
---'23.Minimum 6"stone or compacted below tank and dbox -°"
24.Manhole covers within 6"of grade,pump chamber cover to grade ,1/4.....-----
25.
....,/25.Inspection port on plastic chambers/leach field �----'-
26.Electrical permit for pump chamber/Separate meter for duplexes L.,------
27.
/27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet, under driveway/parking ,,,.---
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature
-C--- .21
35.Foundation footing min. 2 feet above adjusted ground water for new house C ----''
36.Deed Restriction required max. #bedrooms: max. flow: gpd _.-------
37.Check area lots for groundwater/Label groundwater in Assessor's Map .----"
Plan reviewed by:
E 6/03/03