Loading...
HomeMy WebLinkAboutReview Checklist Irkl---2-÷7 Q TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /2-7 Lot o. Zone of Contribution: In Out `."----Acreage �� � �/��� Commercial: Residential: N/"� Street: Village: 40" Floor Plan: L./- #Bedrooms: '9 Owner: it('"%ilfai-44_ Installer: 7 %Li* /1-3 - .0 Phone: Phone: L--2e ty 'e ,at Builder: 7Engineer: h-124,/,1 / l Address: / Phone: - - Phone: I - < 4,1 ,7 /1".'"L,', trt, - j,, ' ,:i ems' 7/477'0-4,7 -(542 '7 IST/A YE NO / 1.Required#of copies received C 2.Date of soils exam and percolation test not older than 2 years LY 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road �J"�/C�H.F... Fnd: 4 Tar.: c ti---- 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands t,-----" 7. Septic tank minimum 10 ft from foundation, deck Var.: -- 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �----" 9.Leaching minimum 100 ft from wetlands Var.: �:/- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: (.....--- 11.Tank/leaching minimum 10 ft from property line Var.: ....----- 12. System meets all other setback requirements Var.: l..-- -' 13.Uses adjustment for maximum high groundwater Var.: . 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: .-- 15. System not in top or subsoil(A,B horizons)or 5'fomovaav` %.....------- 16. r---- 16.Proposed contours are suitable t...--- 17. �,17. System meets slope requirements-min. 1/8", 1/4"preferred (_.---- 18. System meets breakout requirements PVC liner: Wall: L------- 19. -/19. Specified tee sizes are proper, gas baffle on outlet tee %.------- 20. .-/20. Sewage is under 10,000 gpd for parcel u-- 21.No garbage disposal 1/4.------- 22. ✓22. System adequately sized for its intended use L...----- 23. ---'23.Minimum 6"stone or compacted below tank and dbox -°" 24.Manhole covers within 6"of grade,pump chamber cover to grade ,1/4.....----- 25. ....,/25.Inspection port on plastic chambers/leach field �----'- 26.Electrical permit for pump chamber/Separate meter for duplexes L.,------ 27. /27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking ,,,.--- 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature -C--- .21 35.Foundation footing min. 2 feet above adjusted ground water for new house C ----'' 36.Deed Restriction required max. #bedrooms: max. flow: gpd _.------- 37.Check area lots for groundwater/Label groundwater in Assessor's Map .----" Plan reviewed by: E 6/03/03