Loading...
HomeMy WebLinkAboutEngineered Plans - 2019SCALE: 1"=20' LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT 55-�9'15 &aWdl-, .0 — 1.0f @ O --74 Y � 74 / r '� '� --72 72 '' vents t — --70 70-- 44.00 �8— — — GATE G Permit'valid for REPAIR OF SEI'T'IC SYS'fFIN . — _5J ONLY:, due . to State and Local septic variances. 0 y Board of Health review and approval "is required for (� anfuture additions/renin atcons/aIterations to 1` sewage' facHities;and/or structui es/dwelling. G6 0 �r1� Yarmouth Health Department APPRC).': v 11 Name Date Survey by. WELLER & ASSOC. YARMOUTHPORT 6A NPOLE Rp. � AR v � � Eii-EEN S v LOCUS MAP LOCUS INFORMATION PLAN REF: 234/051 TITLE REF: 1678/277 PARCEL ID: MAP 135 LOT 12 FLOOD ZONE: NOT IN FLOOD ZONE LOCUS 88 BARNACLE RD. SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 88 BARNACLE ROAD YARMOUTH, MA PREPARED FOR STEVE BROWN JUNE 12, 2019 .%H of tH,q�9cG OF ,ass -1 STEVEN W o D E e^ RUMBA —+ c�i NO. o. 140 O F STE���� MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle50gmail.com SHEET 1 OF 2 994 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS NOTE: TO PREVENT BREAKOUT, THE PROPOSED SEPTIC TANK FINISH GRADE SHALL NOT BE < EL -66.83 FOR A DISTANCE OF 15' AROUND THE INSTALL RISERS &COVERS OVER INLET & PROPOSED D-89 PERIMETER OF THE S.A.S. T.O.F. EL.=75.0± OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED S.A.S. INSTALL RISER &COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE INSTALL A 4" DIAMETER INSPECTION PORT OVER F.G. EL.=74.5± ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. VENT F.G. EL.=74.0± F.G. EL: 72.0± F.G. EL: 72.0(MAX.) L _ �. 9" MIN COVER/ 36" MAX COVER L - 20' L - 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) O S -1X (MIN.) EL -71.701 O S -1X (MIN.) O S -ix (MIN.) 4"SCH40 PVC - 4"SCH40 PVC 4"SCH40 PVC LLT,. 1 14 L 1 11.3" TO .� 418' LIQUID INV.=70.40 INVERT T \INV.=70.65 INV.=66.44 GAS BAFFLE PROPOSED 3 ROWS OF 7 UNITS AT 6.25'/UNITD-BOINV.=68.80 INV.=69.0DB-5SOIL ABSORPTION SYSTEM (PROFILEPROPOSED 1.500 GALLON SEPTIC TANK �) EXIST. SEWER OUTLET RESTORE VEGETATIVE COVER EL. 71.25 BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS PLACE FILTER FABRIC OVER TOP OF CHAMBERS NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING "•' :?• }• BREAKOUT=TOP ELEV.=66.83 PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE LEVEL AND TRUE INV. ELEV.= 66.44 E TO GRADE ON A MECHANICALLY COMPACTED SIX BOTTOM ELEV.= 65.50 EXISTING SUITABLE INCH CRUSHED STONE BASE, AS SPECIFIED IN 2.83' MATERIAL 310 CMR 15.221(2) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 3 x 2.83' = 8.49' 3) PLACE TEE IN D -BOX. (5.50' PROVIDED) USE 3 ROWS OF HI -CAP H2O INFILTRATORS 4) INSTALL INLET & OUTLET TEES W/ BOTTOM OF TESTHOLE: EL: 60.0 _ GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. K%L GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW- - 310 CMR 15.405 (1) (B): 1) A 2.17 FT. VARIANM FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 5.17 FT (MAX) BELOW GRADE VS REWD 3 FT. (1420/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY TOWN WATER. WATER LINE TO BE RE-LOCIED AS SHOWN ON SITE PLAN. S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 O 1 /8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. SOIL LOGS DATE: MAY 8, 2019 SOIL EVALUATOR: DARREN M. MEYER, RS CSE 1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH DEPT. Elm,. TP- 1 Depth 71.00 0" A LOAMY SAND 1OYR 3/2 70.18 10" B LOAMY SAND 1CYR 5/8 67.58 _ 41 " DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 4 BEDROOMS O 110 GPD/BR = 440 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) SEPTIC TANK: 440 gpd x 200% = 880 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (440)/,74 = 594.59 S.F. PRIMARY USE 3 ROWS OF 7 - HI -CAPACITY H-20 INFILTRATOR - NO No BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 21 UNITS x 6.25 LF x 4.73 SF/LF = 620.8 SF TOTAL AREA = 620.8 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(620.8SF) = 459 GPD> 440 GPD req'd ZQ) /ITAR�P� /fc I I I`1 PERC TEST O MEDIUM SECTION lN111 J EL 66.25 SAND HEGHT END CAP 2.5Y 6/8 INFILTRATOR - HI CAPACITY (H2O) CHAMBER 60.01 1 132" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer, R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soli evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Eval. Exam in October, 1999. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 88 BARNACLE ROAD, YARMOUTHPORT, MA Prepared for: Brown System Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 06/12/19 PO BOX 981 EAST SANDWICH, ATA 02537 CHECKED SHEET NO. 508,3622922 DMM 2 Of 2