Loading...
HomeMy WebLinkAboutReview Checklist ll �J 0- ) c �/ TOWN OF YARMOUTH • SEWAGE PLAN REVIEW CHECKLIST zact-- "...,466'1041 Location: A.M. 7 7 Lot Zone of Contribution: In '---------Out Acreage/7 l Commercial: Residential. Street: P1 � f/� Village: 12./- -- Floor Plan: #Bedrooms: � Owner: \r / ,dcea, /�Installer: r� /f. : ./ Q'4/ Address: Phone: •-,:---rj74 Phone: /� 1�<Ctf Builder: Engineer: _/i/ 4•9 - Address: /7 Phone: ,¢, 71:r---110:: Phone: - 0, 1 N/A YES ATO 1.Required#of copies received V/ 2. Date of soils exam and percolation test not older than 2 years t.------ 3.4-5 ft of naturally occurring pervious material, above water table L----• 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: �®-' 5. Water line 10 ft from septic components Var.: �_- 6.Benchmark indicated and shown-NGVD if near wetlands (--- - _ 7. Septic tank minimum 10 ft from foundation, deck Var.: 1 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: c.1 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 1.---® 12. System meets all other setback requirements Var.: �-. _ 13.Uses adjustment for maximum high groundwater Var.: - 14.Leaching set 4-5 ft above adj.water or bottom of Var.: / �- •---� 15.System not in top or subsoil(A,B horizons)or 5' -ai ov. t..- 16.Proposed contours are suitable (.....--- 17. System meets slope requirements-min. 1/8", ' "preferred L..-----" 18. System meets breakout requirements PVC liner: Wall: t_ --• 19. Specified tee sizes are proper, gas baffle on outlet tee t.----- 20. .._-`20. Sewage is under 10,000 gpd for parcel c.-.-- • 21.No garbage disposal (..------ 22. ..---s22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox �__-.. ' 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed .----- 29. ..r29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �- 33.H-20 loading is subject to vehicular traffic, groundwater ...------ 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max.flow: gpd -' 37.Check area lots for groundwater/Label groundwater in Assessor's Map - Plan reviewed by: 6/03/03