HomeMy WebLinkAboutReview Checklist 7 l/ TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M.9/ Lot Pc Zone of Contribution: In • • ff Commercial: Resi 4 6øy .i - al. Street: (� c �� Village: 'e Floor Plan: # Owner: 9Gi‘G,-1 r Installer: AgCQG, Address: Phone: Q---¢7 7- d,(c-3 Phone: Builder: Engineer: t i j/ Iii Address: Phone: -• 7 71--p �' Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years t--- 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: c� 5.Water line 10 ft from septic components Var.: �.. 6.Benchmark indicated and shown-NGVD if near wetlands �-- 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �r 9.Leaching minimum 100 ft from wetlands Var.: �✓ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: �- 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable • 17. System meets slope requirements-min. 1/8", I/4"preferred [ 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel �. ` 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox - 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking �'- 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max.flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03