Loading...
HomeMy WebLinkAbout2019 Apr 23 - Email vonHone, Amy From: vonHone, Amy Sent: Tuesday,April 23, 2019 1:40 PM To: office@bandbexcavation.net Subject: 65 Grandview Drive,Yarmouth As a follow-up to Ricky's inquiry about a possible bedroom expansion to the existing septic system for this property,the existing leach facility(3 galleys with 2' stone=522 gpd under 1978 Title 5 code) is large enough for a maximum 4 bedrooms. A new 1500 gallon septic tank and dbox must be installed. Any building addition beyond the existing house footprint must meet the minimum setbacks to the septic system. Also, the existing plumbing exiting the structure would need to be investigated to determine the possibility of rerouting into a new septic tank. The existing elevations of the 2 pipes exiting the foundation may not be conducive to plumbing into a single tank. Let me know if there are any additional questions. Amy Amy L.von Hone,R.S.,C.H.O. Assistant Health Director Yarmouth Health Department 1146 Route 28 South Yarmouth, MA 02664 (W)508.398.2231 X1240 (F) 508.760.3472 avonhone@yarmouth.ma.us 1