Loading...
HomeMy WebLinkAboutReview Checklist s # z TOWN OF YARMOUTH =' SEWAGE PLAN REVIEW CHECKLIST Location: AM 55 LOT .:;-•- ' Date of Subdivision Approval // .9..2.1 S-* Street _ .4 _ :. S 1. 1. 6/ Zone of Contribution: In Out Village, / .. Commercial Residential Owner: ,ZZc4 /4eg4 Installer %�% Builder: Engineer /%5d,(.(if 90v7 ,,z/irc,e, _...__ ____: N/A YES NO 1. Required number of copies received. 2. Date of soils exam and percolation test not older than 2 yews. i/- 3. 4 /3. 4 feet of naturally occurring pervious material. above :ter table(new construction) L,- 4. Foundation 2 feet above high point of frontingroad for new construction. �i' 5. Water availability letter frm Water t for new construction. ✓ 6. Benchmark indicated and shown-NGVDif near wetlands. 7. Building sewer does not exit center ofhouse. ‘7-- 8. /8. Septic tank a minimum of 10 feet from house and deck. 9. Leaching a minimum of 20 feet from house and 10 feet from_deck- `/' 10.Leaching a minimum of 100 feet from wetlands. �l 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. t_...-----' 12. System meets all other setback L-•uirements_ , _....----- 13. 13. Uses adjustment for maximum hi ! J oundwater. i. / 14. Leaching 4-5 feet above ad-.• -. water table or bottom of test pit. 15. System not in top or subs& or 5 foot removal. ,- 16. Proposed contours are suitable. ;✓ 17. System meets slope requirements- min 1/8"-1/4"preferre t/ 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. ,t,,y 19. Specified tge sizes are proper ggd�ss baffle on outlet tee, "`20. Sewage flow under 10.000 gpd for parcel. : . ,.. 21..No garbage disposal. L 22. System adequately sized for its intended use. - . LI !_I11 1.1 6" Y. , 6 !^S- 1%__L... i ilia._ - . D. o 1 t• ' . d ....9,11 .. 24. Manhole covers within 6" of grade-septic tank and pump chamlcr. .� 25. Electrical prmit for pump chamber.aomber. 26. Pump system " - weep e.check valve. salutary in d-box. alarm on sate circuit. 27. Septic tank and pump chamber to be Factory waterpfed. 28.Vent provided if leaching below 3 feet or under driveway or parking. 29. Engineer to inspect and certify : a. clay removal .- b. wall construction schedule c; commercial system c/ 30. Engineer and Land Surveyor stamp and signature. _� 31. H2O loading when system subject to vehicular traffic. %/. 32. Title V application and fee signed by a licensed installer. 33. Foundation faotin2 feet above adjusted water table. �/ L' 34. Lot subdivided prior to July 31. 1986 - Nitrate Loading. 35. Subdivided prior to April 7. 1989 - Phosphorus Zon 00'. ..� Plan reviewed by: r 7