HomeMy WebLinkAboutEngineered Plan - 2019'v Z PROPERTY LINE Z SITE INFORMATION N G 00 Z a EXISTING CONTOUR ADDRESS: 14 SHANNON COURT, SOUTH YARMOUTH I 10 If 11 A LOAMY SAND 10YR 3/3 B LOAMY SAND 1OYR 5/6 C MEDIUM SAND 1OYR 6/6 PERC ® 55" 120" -2.57 0 10" 36" 78" LOCUS SCALE 1"=500' 7.43 6.60 4.43 ADJ.=1.54 0.61' OBS.=0.93 SOIL PROFILE DATE: MARCH 28, 2019 PERFORMED BY: ASA MINTZ WITNESSED BY: AMY VON HONE, RS, CHO STANDING GW: 78" PERC RAT :<2 MIN./IN. INDEX WELL TSW 89 3/28/19 READING = 10.81 ADJUSTMENT = 0.61 BENCHMARK GAS GATE ELEVATION=7.03 (NAVD88) N/F GIOVANNA LEDDY 15 SHANNON COURT MAP 25, PARCEL 317 SITE EXISTING DWELLING RISERS TO BE BROUGHT TO GRADE 9" MIN. COVER 36" MAX. COVER 8' OF 4" SCH 40 5 1500 GALLON 00 GALLON - - -- - _- -- = SLOPE PVC S _ - ___ _ ---- , 0.020 MIN. L(WATERPROOFED) 0"p" EXISTING 1 " INV.=4.25 INV.=4,50 INSTALL ZABEL A1800 (H20) INV.= -0.25 EFFLUENT FILTER LEVEL STABLE BASE CONSISTING OF 6" CRUSHED STONE PROPOSED 2.000 GAL. 2 -COMPARTMENT LOW PROFILE CONCRETE SEPTIC TANK / PUMP CHAMBER (SHOREY ITEM # STPC202LP30) 1 1/2" SCH 40 rVC WITH 5/16" PERFORATIONS IN THE TOP OF THE PIPE (SPACING SHOWN) 2' \ 5' I 5' 2' CLEANOUT TO GRADE FF� THREADED END CAP -rr- 2' SCH 40 PVC MANIFOLD -1/4" ORIFICE WITH ORENCO 2 SCH 40 PVC ORIFICE SHIELD FORCEMAIN FROM PUMP CHAMBER I' 1-1/2" PIPE TO BE RUN LEVEL 1 � - i I I PRESSURE DISTRIBUTION DETAIL N O+T TO SCALE I i I i s TING 45' BEND MAXIMUM EL.=4.25 U w 31" (352 GALLONS) Z W0 UJ M U) ALARM ON EL.=1. 4" PUMP ON EL.=1.33 0 Z w 7" Q U' Z w 62 CL PUMP OFF EL.=0.75 0 n D V) 1 OF CHAMBER ELEV.=0.25 8 oz. NON WOVEN GEOTEXTILE FABRIC MINIMUM ELEV.=7.00 MIN. COVER 9" (TYP.) ELEV.=6.04 v v v v v v v 39' OF 1-1/2" PERF. SCH 40 PVC S=0.000 v v o o v v v -- - - v o v v - (SEE PRESSURE DISTRIBUTION DETAIL) --- ° v -- v v VV v v v v v v v ELEV.-=-5.-54 3/4"-1 1/2" DOUBLE WASHED STONE 5' I 43' LONG BY 7' WIDE LEACHING BED I 5' - LIMIT OF EXCAVATION - SOIL REMOVAL TO BE TO APPROXIMATE ELEVATION 4.43 --------------- ------------------------------------------------- SYSTEM PROFILE NOT TO SCALE INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE F je5���READED UNION BALL VALVE I L_ �-STAINLESS STEEL LIFTING CHAIN OR CABLE " WEEP HOLE 2" CHECK VALVE 2" SCH 40 PVC RISER PIPE MYERS SRM4 4/10 HP PUMP OR APPROVED EQUAL - - - - - - - - - - - - - -� 6.86 D �%L► r 7• T j � #i2 SHANNON CO G U�T VINCENT FALANGA PUMP CHAMBER DETAIL 12 SHANNON COURT NOT TO SCALE 69 \ MAP 25, PARCEL 315 m � PROPOSED 2,00 GALLON SEPTIC TANK, PUMP CHAMBER 6.69 3 COMBINATION. 1500 GALLON TANK, 0 0 500 GALLON PUMP CHAMBER (H20) 6.77 1 ,((/ / 6' SiJ OCKADENCE �' / 7.86 7 50 \� PROPOSED 7'X 43' I 3 \ PIPE IN STONE LEACH FIELD I 0 ' (PRESSURE DISTRIBUTION) 76-1 I EXISTI G CESSPOOL TO BE \ � � � 1 727» W 1 \ � EXISTING SHED PUMP AND REMOVED OR \ i I TP -1 18.44. TO BE MOVED 3 BACKFILLED O 7.43 (TYP.) LOCATION \ 1 ) / 16.97 7 _ o , %: "_ _43 0, \\ / pROPER�. L W �� :' `' ' [� 6.67 6.50 C .>y 7.02 ��� "' `' ' :',:` .. -Ni, : \ CLEANOUT / rV _ z: fir•.• (TYP.) LIMIT OF STONE. m / 7,IN INSPECTION PORT d, / o - / v� G -- cYi LIMIT OF OVERDIG.01 i w cv J 7.83 N/F / LING JOHN AHIGIAN #14 SHANNON COURT it z LOT 68 57 BRIAR CIRCLE ROOM / i= 4,305 SQ. FT. t MAP 25, PARCEL 346 z 0.10 ACRES ± EXISTING DECK 7.65 I 7.35 1 6' STOCKADE FENCE N/F .06 DANIEL J GRIFFIN , 51 BRIAR CIRCLE MAP 25, PARCEL 344 133'6N �9„ E N 70 4� N/F ANDREW RATIN 53 BRIAR CIRCLE MAP 25 PARCEL 345 FLOOR PLAN NOT TO SCALE 6' STOCKADE FEN 8.34 THREADED END CAP .,:.:P��iFaRATEQ�::;P.I�J=•�'•':;>.: s INSPECTION PORT DETAIL NOT TO SCALE - 4' MIN. ELEV.=1.54' p SEASONAL HIGH GROUNDWATER 8 oz. NON WOVEN GEOTEXTILE FABRIC 1-1/2" PERFORATED SCH 40 PVC PIPE 9„ MIN. EARTH -- _ - EARTH BACKFIL - - -- BACKFILL----- .. --- - -717 8" DEPTH OF 3/4" TO a ° o o\ a °17 o ° ° ° ° ° � ` 1-1/2" DOUBLE WASHED ° ° c ° ° ° ° v ° v ° 1-7 CRUSHED STONE 1'-9" 3'-6" 7' -0" LEACH FIELD CROSS SECTION NOT TO SCALE LEGEND 10. WHERE APPLICABLE, UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT., OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. 11. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 12. EXISTING CONDITIONS SURVEY PERFORMED BY PAUL E. SWEETSER, PLS, APRIL 2019 13. USE GROUNDWATER WATER ADJUSTMENT OF 0.61' PER YARMOUTH HEALTH DEPARTMENT APPROVAL DEED RESTRICTION i IN ACCORDANCE WITH 310 CMR 15.240 (5), THIS SYSTEM REQUIRES A DEED RESTRICTION LIMITING THE DWELLING TO 2 BEDROOMS. IT IS REQUIRED THAT THIS DEED RESTRICTION BE RECORDED WITH THE BARNSTABLE COUNTY REGISTRY OF DEEDS. DESIGN CALCULCATIONS i DESIGN FLOW 110 GALLONS/DAY/BEDROOM X 2 BEDROOMS = 220 GALLONS/DAY j TANK CAPACITY 220 GPD X 200% = 440 GALLONS j USE 2,000 GALLON TWO-COMPARTMENT TANK FOR TANK AND PUMP CHAMBER REQUIRED LEACHING CAPACITY DESIGN PERC RATE = < 2 MIN/INCH 220 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 297.30 SQ. FT. PROVIDED LEACHING CAPACITY BOTTOM AREA = 7.0' X 43.0' = 301.00 SQ. FT. (222 GPD) PUMP NOTES 1. USE MYERS MODEL SRM4 4/10 HP PUMP OR APPROVED EQUAL 2. BOTH VISUAL AND AUDIO (AUDIBLE AND LIGHT) ALARMS ARE TO BE LOCATED WITHIN THE E DWELLING AND BE POWERED BY A SEPARATE CIRCUIT FROM THE PUMPS 3. ELECTRIC JUNCTION BOX SHALL BE EXPLOSION PROOF NEMA 4X AND SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER IN A SEPARATE STRUCTURE. ALL ELECTRICAL CONNECTIONS I SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER 4. PUMP SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND Till 5 REGULATIONS. 5. THE PUMP SHALL BE ABLE TO BE REMOVED FROM THE PUMP CHAMBER WITHOUT ENTERING THE STRUCTURE 6. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS IN THE FORCEMAIN 7. AN ELECTRICAL PERMIT IS REQUIRED FOR THE INSTALLATION OF THIS SYSTEM I PUMP CHAMBER VOLUMES i 1. PUMP CHAMBER VOLUME = 134.6 GALLONS PER FOOT OF HEIGHT 2. VOLUME DOSED PER PUMPING CYCLE = 74 GALLONS OR 0.54' (6.5") 3. EMERGENCY STORAGE = 220 GALLONS OR 2.50' (20") 4. DOSES PER DAY = 3 BOUANCY CALCULATIONS 1 2.000 GALLON L.P. SEPTIC TANK/PUMP CHAMBER (H-20) ASSUME FULLY COVERED IN FLOOD PLAIN l VOLUME OF TANK - 13' X 7' X 6.17 a 561.47 C.F. 561.47 C.F. X 62.4 LBS/C.F. 35,035 LBS UPLIFT WEIGHT OF EMPTY S.T. / P.C. = 33,500 LBS DOWNFORCE ' WEIGHT OF SOIL ON S.T. / P.C. a 4,272 LBS DOWNFORCE WEIGHT OF SOIL ON TOP OF TANK = 2,365 LBS DOWNFORCE TOTAL OOWNFORCE 37,772 LBS DOWNFORCE IN HOUSE VARIANCES REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SAS TO CELLAR WALL SHALL BE 20 FEET. SAS IS LOCATED 19.7 FEET FROM THE CELLAR WALL. A VARIANCE OF ±10.3 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SAS TO PROPERTY UNE SHALL BE 10 FEET. SAS IS LOCATED ±5.0 FEET FROM THE PROPERTY UNE. A VARIANCE OF ±5.0 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SEPTIC TANK TO CELLAR WALL SHALL BE 10 FEET. SEPTIC TANK IS LOCATED 17.0 FEET FROM THE CELLAR WALL. A VARIANCE OF ±3.0 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SEPTIC TANK TO PROPERTY LINE SHALL BE 10 FEET. SEPTIC TANK IS LOCATED 14.7 FEET FROM THE PROPERTY LINE. A VARIANCE OF 15.3 FEET IS REQUESTED. 310 CMR 15.212 (1) - DEPTH TO GROUNDWATER - MINIMUM VERTICAL SEPARATION FROM BOTTOM OF SAS TO HIGH GROUNDWATER SHALL BE 5 FEET. BOTTOM OF SAS IS LOCATED 4 FEET ABOVE HIGH GROUNDWATER. A VARIANCE OF 1 FOOT IS REQUESTED. LOCATION.' f 14 SHANNON COURT SOUTH YARMOUTH, MA 02664 ' 1 CL/ENT DENNIS AND LEE ROBERTS 121 FOX RUN DR LUDLOW, MA 01056 ' DRAY/NG T/TLE SUBSURFACE SEWAGE DISPOSAL SYSTEM 1 SITE PLAN AND PROFILE SCALE.• ]-IFATE DRAW/NG NO. j 1"=10 4/10/19 1 OF 1 PROPERTY LINE SITE INFORMATION ------------------104 ------------------ EXISTING CONTOUR ADDRESS: 14 SHANNON COURT, SOUTH YARMOUTH I ----104 - - - - PROPOSED CONTOUR MAP OT: DEED REFERENCE: 30408/277 X X EXISTING FENCE GENERAL NOTES: OHP EXISTING OVERHEAD UTILITIES W EXISTING WATER LINE 1. THE SUBJECT PROPERTY IS WITHIN THE LIMITS OF THE 100 -YR FLOODPLAIN (AE EL. 11) AS SHOWN ON PANEL NO. 25001 CO589J, EFFECTIVE DATE JULY 16, 2014. ; G : G EXISTING NATURAL GAS LINE .o 2. THE SITE NOT IS LOCATED WITHIN A ZONE II AREA. 3. THERE ARE NO STREAMS OR WETLANDS WITHIN 100 -FEET OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM. j' `" > L `' z = �( TP -1 LOCATION OF TEST = PIT/PERC TEST 4. VERTICAL DATUM IS NAV088 99.76 X EXISTING SPOT ELEVATION 5. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE' ^" REGULATIONS AND LOCAL BOARD OF HEALTH AND BUILDING DEPARTMENT REGULATIONS. ti L `gig �FH EXISTING FIRE HYDRANT 6, ALL JOINTS IN THE TANK/PUMP CHAMBER AND DISTRIBUTION BOX SHALL BE MADE WATERTIGHT THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC CEMENT. j == °' ° 0 s "rte. -.a ` UP -O EXISTING UTILITY POLE 7. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO ANY EXCAVATION OCCURRING. ".'.0E' .' ,: ® WG EXISTING WATER GATE BOX 8. LOCATION OF UTILITIES ON THIS PLAN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE ` '- > } BH BULKHEAD FIELD. THE ELEVATIONS OF ALL EXISTING SEWER INVERTS SHALL BE VERIFIED PRIOR TO THE `" �+, CH CHIMNEY INSTALL OF ANY SYSTEM COMPONENTS. ANY DISCREPANCIES SHALL BE REPORTED TO THE S. CQ 3 �` , DESIGN ENGINEER IMMEDIATELY `� C6 C)m. y; AGM EXISTING GAS METER 9. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR TO ; ®IP PROPOSED INSPECTION PORT BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF INSPECTIONS 1 10. WHERE APPLICABLE, UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT., OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. 11. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 12. EXISTING CONDITIONS SURVEY PERFORMED BY PAUL E. SWEETSER, PLS, APRIL 2019 13. USE GROUNDWATER WATER ADJUSTMENT OF 0.61' PER YARMOUTH HEALTH DEPARTMENT APPROVAL DEED RESTRICTION i IN ACCORDANCE WITH 310 CMR 15.240 (5), THIS SYSTEM REQUIRES A DEED RESTRICTION LIMITING THE DWELLING TO 2 BEDROOMS. IT IS REQUIRED THAT THIS DEED RESTRICTION BE RECORDED WITH THE BARNSTABLE COUNTY REGISTRY OF DEEDS. DESIGN CALCULCATIONS i DESIGN FLOW 110 GALLONS/DAY/BEDROOM X 2 BEDROOMS = 220 GALLONS/DAY j TANK CAPACITY 220 GPD X 200% = 440 GALLONS j USE 2,000 GALLON TWO-COMPARTMENT TANK FOR TANK AND PUMP CHAMBER REQUIRED LEACHING CAPACITY DESIGN PERC RATE = < 2 MIN/INCH 220 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 297.30 SQ. FT. PROVIDED LEACHING CAPACITY BOTTOM AREA = 7.0' X 43.0' = 301.00 SQ. FT. (222 GPD) PUMP NOTES 1. USE MYERS MODEL SRM4 4/10 HP PUMP OR APPROVED EQUAL 2. BOTH VISUAL AND AUDIO (AUDIBLE AND LIGHT) ALARMS ARE TO BE LOCATED WITHIN THE E DWELLING AND BE POWERED BY A SEPARATE CIRCUIT FROM THE PUMPS 3. ELECTRIC JUNCTION BOX SHALL BE EXPLOSION PROOF NEMA 4X AND SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER IN A SEPARATE STRUCTURE. ALL ELECTRICAL CONNECTIONS I SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER 4. PUMP SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND Till 5 REGULATIONS. 5. THE PUMP SHALL BE ABLE TO BE REMOVED FROM THE PUMP CHAMBER WITHOUT ENTERING THE STRUCTURE 6. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS IN THE FORCEMAIN 7. AN ELECTRICAL PERMIT IS REQUIRED FOR THE INSTALLATION OF THIS SYSTEM I PUMP CHAMBER VOLUMES i 1. PUMP CHAMBER VOLUME = 134.6 GALLONS PER FOOT OF HEIGHT 2. VOLUME DOSED PER PUMPING CYCLE = 74 GALLONS OR 0.54' (6.5") 3. EMERGENCY STORAGE = 220 GALLONS OR 2.50' (20") 4. DOSES PER DAY = 3 BOUANCY CALCULATIONS 1 2.000 GALLON L.P. SEPTIC TANK/PUMP CHAMBER (H-20) ASSUME FULLY COVERED IN FLOOD PLAIN l VOLUME OF TANK - 13' X 7' X 6.17 a 561.47 C.F. 561.47 C.F. X 62.4 LBS/C.F. 35,035 LBS UPLIFT WEIGHT OF EMPTY S.T. / P.C. = 33,500 LBS DOWNFORCE ' WEIGHT OF SOIL ON S.T. / P.C. a 4,272 LBS DOWNFORCE WEIGHT OF SOIL ON TOP OF TANK = 2,365 LBS DOWNFORCE TOTAL OOWNFORCE 37,772 LBS DOWNFORCE IN HOUSE VARIANCES REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SAS TO CELLAR WALL SHALL BE 20 FEET. SAS IS LOCATED 19.7 FEET FROM THE CELLAR WALL. A VARIANCE OF ±10.3 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SAS TO PROPERTY UNE SHALL BE 10 FEET. SAS IS LOCATED ±5.0 FEET FROM THE PROPERTY UNE. A VARIANCE OF ±5.0 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SEPTIC TANK TO CELLAR WALL SHALL BE 10 FEET. SEPTIC TANK IS LOCATED 17.0 FEET FROM THE CELLAR WALL. A VARIANCE OF ±3.0 FEET IS REQUESTED. 310 CMR 15.211 (1) - MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SEPTIC TANK TO PROPERTY LINE SHALL BE 10 FEET. SEPTIC TANK IS LOCATED 14.7 FEET FROM THE PROPERTY LINE. A VARIANCE OF 15.3 FEET IS REQUESTED. 310 CMR 15.212 (1) - DEPTH TO GROUNDWATER - MINIMUM VERTICAL SEPARATION FROM BOTTOM OF SAS TO HIGH GROUNDWATER SHALL BE 5 FEET. BOTTOM OF SAS IS LOCATED 4 FEET ABOVE HIGH GROUNDWATER. A VARIANCE OF 1 FOOT IS REQUESTED. LOCATION.' f 14 SHANNON COURT SOUTH YARMOUTH, MA 02664 ' 1 CL/ENT DENNIS AND LEE ROBERTS 121 FOX RUN DR LUDLOW, MA 01056 ' DRAY/NG T/TLE SUBSURFACE SEWAGE DISPOSAL SYSTEM 1 SITE PLAN AND PROFILE SCALE.• ]-IFATE DRAW/NG NO. j 1"=10 4/10/19 1 OF 1