Loading...
HomeMy WebLinkAboutVariance for Holding Tank - 1999IOU OFF5 —� 50' OFFSET 5.8 BORDERING 5.1 E<, - VEGETATED 5 4-� � 4. W E T L A N D DELINEATION BY ENSR – 12-10-1998 FIELD LOCATION BY BAXTER & NYE, INC. – 12-11-1998 J w m L�1 � �--T E LL A N 64 C ; 4.5 ! 6_ .R AT } �G Q B3 / t t � �-_ I 82 5.0 //t r Pvi FOR _ 0 T 1 _ L A,P: B00: 2 F'A,. E 4 C 7,533 Square Feet f A5 �� p0 x I 4.5 ED -•QPos (.�w►�t a f `d�/ork '�� RtuiSe�Q Sanua 23� q / '-� 19 q f GE OF CLEARING s ' BAXTER & NYE, INC. . V. A6 Ile r.�F, 6ss�Jorj1 olerwl�rh 5- \ sr\'�, 812 MAIN STREET ` /\ OSTERVILLE, MASS., 02655 4.1 wifi� suncQ\ps T / - . _ (508)-428-9131 A4 STK SET x 5 �\ FraposG Z000 Ga I � � HrJlei iY1S ?a►,k RY j 4.7 5.GRAPHIC SCALE 8 f �x t^ i EXISTING CESSP ---- QOL t A . ae ao TOP EL = 5.8' "a �� r `' A �6.1 ' ft, y -'� , v WATER LEVEL EL 3.1' 1, // int _ '�>� ' � ,� �; 4 `- IN FEET �F+ 1 inch = 20 ft, / 5 oo 3 BORDERING �O, ..\ IRON PIPES FOUND` O O t i 2ti6 2 POLE - ` HAND–AUGERED TEST HOLE ELEVATION TO TOP ! VEGETATED f4.7 px`, zAT BUILDING = 6.35' '%`x 7.3 12–Q9-1998 WETLAND 1p'OFF BLDG=6.06' - 6. ? GROUND ® TH EL 6.5 0 WATER IN TH EL = 2.4' .3 �4rri, t_��ht io he 3 2� 7.3_ DELINEATION BY ENSR — 12-10-1998 j -- "*k o`q n ov„� o n 1 8000 LINA _ �/ s FIELD LOCATION BY BAXTER & NYE, INC. 12-11-1998 f \ - - . Al Al 6.'F co xt JOHN / E. ( 5.9 W�ERVICE / FLAG x 6.3 6.3/ #x ' sf6`ic`sERt S�S� 6.2 cI n LL 50' OFFSET o \ o J� F 1 - 2S EDGE OF CLEARING v t N o. 0 T 0 OFFS T Pi.fj,f�! �C`+ ` J ;'fig'_ 100' E ` P ` ' \ >� 636 Square Feet f `�P�SH OF lfgs\ 6.9 ,ril I/�� STEPHEN cy I 'rte ALL No. 3,112-6 ; 1 J w m L�1 � �--T E LL A N 64 C ; 4.5 ! 6_ .R AT } �G Q B3 / t t � �-_ I 82 5.0 //t r Pvi FOR _ 0 T 1 _ L A,P: B00: 2 F'A,. E 4 C 7,533 Square Feet f A5 �� p0 x I 4.5 ED -•QPos (.�w►�t a f `d�/ork '�� RtuiSe�Q Sanua 23� q / '-� 19 q f GE OF CLEARING s ' BAXTER & NYE, INC. . V. A6 Ile r.�F, 6ss�Jorj1 olerwl�rh 5- \ sr\'�, 812 MAIN STREET ` /\ OSTERVILLE, MASS., 02655 4.1 wifi� suncQ\ps T / - . _ (508)-428-9131 A4 STK SET x 5 �\ FraposG Z000 Ga I � � HrJlei iY1S ?a►,k RY j 4.7 5.GRAPHIC SCALE 8 f �x t^ i EXISTING CESSP ---- QOL t A . ae ao TOP EL = 5.8' "a �� r `' A �6.1 ' ft, y -'� , v WATER LEVEL EL 3.1' 1, // int _ '�>� ' � ,� �; 4 `- IN FEET �F+ 1 inch = 20 ft, / 5 oo 3 BORDERING �O, ..\ IRON PIPES FOUND` O O t i 2ti6 2 POLE - ` HAND–AUGERED TEST HOLE ELEVATION TO TOP ! VEGETATED f4.7 px`, zAT BUILDING = 6.35' '%`x 7.3 12–Q9-1998 WETLAND 1p'OFF BLDG=6.06' - 6. ? GROUND ® TH EL 6.5 0 WATER IN TH EL = 2.4' .3 �4rri, t_��ht io he 3 2� 7.3_ DELINEATION BY ENSR — 12-10-1998 j -- "*k o`q n ov„� o n 1 8000 LINA _ �/ s FIELD LOCATION BY BAXTER & NYE, INC. 12-11-1998 f \ - - . Al Al 6.'F co xt JOHN / E. ( 5.9 W�ERVICE / FLAG x 6.3 6.3/ #x ' sf6`ic`sERt S�S� 6.2 cI n LL 50' OFFSET o \ o J� F 1 - 2S EDGE OF CLEARING v t N o. 0 T 0 OFFS T Pi.fj,f�! �C`+ ` J ;'fig'_ 100' E ` P ` ' \ >� 636 Square Feet f `�P�SH OF lfgs\ 6.9 ,ril I/�� STEPHEN cy I 'rte ALL No. 3,112-6 ; CB/NO DH EL >= 5.89' 5-� ... - 5P E #28/1 z;r i j 5.3 98129 (SITE03.DWG) { w. CbiV57Rr.�CT7acl �l�Tc S t) Nd WOR;t' SHt41.L. Pj26GE-S D V►JTILL APPROVALS HAVh —D =r;om THE YRl�rYl5CJrH BO/}R9 v 'F3 �.�iJ pi..Tt1 t ti� 1 , ,sA t -Til AICD R. C O N S A+ thsz. 1^ r a ,.)j. __-'-jr{✓{� f7r,cikI}-� 6 •. .T r GY` W—i-crprc*of-,n� o T�c.rtic uptn<. �l�nll Lac t7 rmcc� !�•� f-hQ S i fz Lae- re. 'u e� c h - f -+ l l t t -t 3) r'A1u}b,c 1 �vtic�itvt� �C1r1��Cer� AVLY1l.0 �" 1^lJtnL++.+++•+ (,ouar $o �h� C�ovc�^ L 12n1z- fv be Lm,,f-rS -}ierovJ 1 axlst'?n{� 5%QC4>r Irl uUt1 IrtC�. I 14, S wcyANCY If PtLCUL-ATIO" s 13.O 17 0bs- G.W it t x �t x 4,5 x 4Z.4110J 18,563 Has W a 4cr �roc� �O tYlt Wcc7Ht as H -2.C) Sc�izc ."rank. 12lz Tov,s x Z,aoo S�}� Fzac�cr 2S PDO = 1135 (4T,d low Ig)563 /add? C o nc,retc Slam i -o "Toys eif Tants J J x x -a-/ X 140 16, ICF = 6 1(:�, O 16S 3/ !mss -- MOLDING I ANK F ���rurc 5T ?00.0 - H- 20 or cgval ' Pour g„ Slab Gip hoIAIr<S ta rl H-1 (aux(" Wirc f"I(OLDit lG 1 f�1`1K• Di=TAIL.S r �Dr LewkS 13A4 'YArCHT CLUB 179 BIERR`tj PcV E-QUE ZA%,tVA9Y 2S) 1999 aANT- R t N)"M , TOC ReGISTOZk-D LtWO SUtR\)E-YOP-5 i CIVIL. E7s6l�JE15r2S 8( Z MAIM ST)emE'r O S'E-ER V I L L 9 ry) jA S S, f a 961? -9 p. d 4 �.4c Co if ),F loot Sw,ith (�r ° -loot alarm t 0 31_Qr .Flock -s' Atc�rrvt O S+O" Ile S7 c 7 1 z > >v 1 � s Of tr o D ti, Q 3/ !mss -- MOLDING I ANK F ���rurc 5T ?00.0 - H- 20 or cgval ' Pour g„ Slab Gip hoIAIr<S ta rl H-1 (aux(" Wirc f"I(OLDit lG 1 f�1`1K• Di=TAIL.S r �Dr LewkS 13A4 'YArCHT CLUB 179 BIERR`tj PcV E-QUE ZA%,tVA9Y 2S) 1999 aANT- R t N)"M , TOC ReGISTOZk-D LtWO SUtR\)E-YOP-5 i CIVIL. E7s6l�JE15r2S 8( Z MAIM ST)emE'r O S'E-ER V I L L 9 ry) jA S S, f a 961? -9 BRADDOCK ST. Y POINT CU REQUESTED VARIANCES: REQUESTING A VARIANCE TO HAVE A 4' SEPARATION TO GROUNDWATER INSTEAD OF THE REQUIRED 5' SEPARATION. THE GROUNDWATER ADJUSTMENT HAS BEEN APPLIED. LOT 33 LOT 34 V Q z 5 0_ 00 a0 O / SPINK O EL. U 0 cn z EC EROSION CONTROL 0 DH DEEP HOLE 59 CLAY STREET F- O/E Ld MIDDLEBORO, MASSACHUSETTS NOTES 3.7 O 02346-1052 SANDY LOAM � TOWN'S BOARD OF HEALTH. 2.1 Q Z No 774-766-0544 OR 774-678-9066 jspinkl@gmail.com ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. -5.2 a ry m 0 L OCUS M Sc a e: TS NOTE: SAS IS GREATER THAN 70 FROM THE SAS. <<� LOT 35 N/F WOODBURY Book, Page: 13734, 299 0 4. Property ID: 34/ 223/ o b 00 0 o y,n rn rnN 1 -4N o "a WF -1 N81190't 003mc rnv,c z- �c mm�wv )0 co vn �� 03 rn m \' SB F LOOS \ WF- 2 -cyvv 0Zo z z AppROX. AS LOT 36 N EXISTING \ \ ESSPOOL DWELLING STAKED SILT FENCE Z o w m II ,� pWELUNG DECK SILL=4 S5 \0 AND SILLT SOCK TO BE INSTALLED PRIOR TO ANY �I ILL 492 EXCAVATION FIELD WORK 0 o SEE DETAIL c i DECK x3.7 \ ( ) WATER sr / \ \� WF -3 0 VN APP `� \ ENTS A / ��� WF -4 DR' < \ I. � 4.1 �x... L. \ LOT 37 \ j° NTO AL W \ N/F w,V00DBURY r WF -5 1 0 orn -0 x3.7 Book, Page: 1266 + , 285 -C .• o \ Proper y ID: 34/ 25/ m o"�'' �m 4 \ 0.97 Ares \ 1 m ' tP ?. • �' x PLAN OK. 72 PG. 51 \ -_ r rri v �, N \ WF -6 4.4LA <4. L w \-z_ -10 �� 56 S.F. 9 IN PEC ON _ 7' `ro. 13, 2 P 4.5x o LOT 38 1 $' 01 4.6 x4.8 , -A �0 � a i 6'09., CB x5.2 � NSC(F) A B.M. NAIL IN 4�.� TREE EL.=6.53 �� 9,480 S.F. (N.A.V.D. 88) �• Ate• LOT 39 "F-7 'VO O Q" \ 19g'f I' / N/F LUCIANO Book, Page: 2955, 286 LOT 40 Property ID: 34/ 226/ I ' cn _> >D SPINK SOIL MOTTLING EL. 0" - 6" DESIGN 0 W WELL G PRC PERC TEST EC EROSION CONTROL 0 DH DEEP HOLE 59 CLAY STREET 6" - 13" O/E t° MIDDLEBORO, MASSACHUSETTS NOTES 3.7 13"-33" 02346-1052 SANDY LOAM 10YR5/8 TOWN'S BOARD OF HEALTH. 2.1 a N MED. SAND 774-766-0544 OR 774-678-9066 jspinkl@gmail.com ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. -5.2 00 .O.F. = 106.0± BRING ALL THREE COVERS TO FINISHED GRADE WITH METAL MANHOLE COVERS FINISHED GRADE H-20 LOADING 1 � T I I� I II TI - J L MANHOLE COVER I 24" DIAMETER MIN. (TYP.) 10.5'', 1500 GAL. SEPTIC TANK USE WIGGIN PRECAST TANK OR SIMILAR DRAWING IS NTS TP N0. 1 GRD. EL. 4.8± GW. EL. .1 +1.54'=1.64' SURFACE DEPTH SOIL HORIZON SOIL TEXTURE SOIL COLOR SOIL MOTTLING EL. 0" - 6" FILL 0 W WELL G PRC PERC TEST EC EROSION CONTROL 0 DH DEEP HOLE 4.3 6" - 13" O/E SANDY LOAM 10YR2/2 NOTES 3.7 13"-33" B SANDY LOAM 10YR5/8 TOWN'S BOARD OF HEALTH. 2.1 33"-96" C MED. SAND 10YR6/6 ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. -5.2 4. ALL TANKS, D -BOXES, AND CHAMBERS SHALL BE SET LEVEL AND TRUE TO GRADED ON A MECHANICALLY COMPACTED STABLE BASE. 5. AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED TO MINIMIZE EROSION. THE AREA IESTIMATED SEASONAL GROUND WATER ELEV. EL. .1' + 1.54' (1.64') ADJUSTED PT N0. A GRD. EL. 4.8± PERC DEPTH 25" START 15 MIN. PRESOAK: 2:26 IA.M. END 15 MIN. PRESOAK: 2:35 A.M. TIME AT 12": TIME AT 9": TIME AT 6": WOULD NOT HOLD THE PRESOAK PERC RATE: <2 M.P.I. BRING BOTH COVERS p LAN 8c P 0 F I LE TO FINISHED GRADE WITH METAL MANHOLE COVERS BRING D -BOX COVER TO F\\/x\/x\/�/�/ WITH I AI CONCRETERADE COVER FORCE MAIN EXTEND LIND' RETAINING W (SEE DETAIL,' 2.3± 1.75 L. .t- '. '• 3" MIN 4" PVC PIPE3• MIN e 7 OUTLETS_ 3 SLOPE OF .03 PLUGGED 0 • :' 1.08 Z L = 13' ' 1.33 ; ' e SANITARY TEE D83 D- BOX r ' , . •' • • r, -.'e .'. ..�. •� . BAFFLE BOX QO 0°a 4 �° 0�° Q�° Q °s4 6" CRUSHED STONE 310 CMR 15.232 0 0°e O e 0° 0 0 0 40 60 8 0 °e` �0 e 0 H-20 LOADING PROPOSED 1,000 GALLON TANK WATERPROOFED 6" CRUSHED STONE ON A COMPACTED STONE BASE SEE DETAILS H-20 LOADING USE SHEA PRODUCTS OR SIMILAR DRAWING IS NTS ALL TANKS ARE TO BE WATERPROOF 00 L6 DEEP HOLE SOIL EVALUATOR: THOMAS ROUX APPROVING AUTHORITY. AMY VON HONE DATE PERFORMED: JULY 19, 2018 ADJUSTED G.W. AT 1.64 SOIL EVALUATION PERFORMED BY: THOMAS ROUX SOIL EVALUATOR LICENSE NUMBER: SE2703 I CERTIFY THAT I HAVE TAKEN AND PASSED THE SOIL EVALUATOR CLASS ON OCTOBER OF 2000 THE FILL, A AND B LAYERS ARE TO BE STRIPPED OUT DOWN TO THE ELEVATION WHER THE C -LAYER BEGINS. TITLE 5 SAND WILL BE USED TO BUILD UP TO EL. 5.64. THE STRIP OUT WILL OCCUR FROM THE SURFACE DOWN TO EL. 2.1 (BEGINNING OF THE C -LAYER). BUILD UP FROM EL. 2.1 UP TO EL. 5.64 (3.54' OF SAND±). �oF�As SIGN DATA DESIGN s �P qcy oZ G13 � A. o BUNwrz LOT 41 No. 503 PROJECT: SEPTIC SYSTEM DESIGN PLAN 12--(7-18 PREPARED FOR: DALE NUSSBICKEL' orow 92 BREEZY POINT RD. a u YARMOUTH, MASSACHUSETTSw. 02035 l?NALE�, • TYPE OF BUILDING: SINGLE FAMILY DWELLING TOTAL NUMBER OF EXISTING BEDROOMS: !4 DESIGN FLOW: 110 GAL./BEDROOM/DAY DESIGN FLOW: 4 BEDROOMS X 110 GAL./BEDROOM = 440 GAL./DAY SEPTIC TANK CAPACITY: REQUIRED: 440 GPD X 200% =880 GPD SEPTIC TANK PROVIDED = 1500 GAL. (NEW SEPTIC TANK) NO GARBAGE GRINDER ALLOWED. SEPTIC TANK VOLUME: 1500 GAL LTAR=.74 gpd/sf 0 conn LEACHING CAPACITY PROVIDED: H-20 CAPACITY LEACHING CHAMBER BED 12 LEACHING CHAMBER UNITS WITH A .5'; GAP BETWEEN THE CHAMBERS AND 2' OF STONE ALL AROUND 12 UNITS AREA OF 36'X17 =612.0 S.F. 612 SQ. FT. x .74 GPD/ SQ. FT. = 452.9 GPD SINCE 452.9.4 GPD > 440 GPD O.K. FINISHED GRADE 2% MIN. SLOPE 7.3 MIN. FINISHED GRADE o a o FILTER FABRIC TO BE °' a INSTALLED OVER THE CHAMBER CL AND THE 2' OF STONE 6.35 5.89 5.64 H-20 LOADING 12 - CULTEC C-4 PANEL v SEE PLAN FOR CHAMBER CONFIGURATION o 0 0 THERE WILL BE A 5' SAND OVERDIG THERE IS 2' OF STONE AROUND THE ENTIRE PERIMETER OF THE CHAMBERS THE STONE EXTENDS THE ENTIRE DEPTH OF THE CHAMBERS 8.5". GROUNDWATER ® 1.64'± SEE WALL DETAIL AROUND THE SAS LEGEND 0000c�o SW STONE WALL ® CB CATCH BASIN TL TREE LINE 1 BM BENCH MARK Os SMH SEWER MANHOLE $ UP UTILITY POLE 0 DMH DRAIN MANHOLE :�C HYD FIRE HYDRANT 0 W WELL G PRC PERC TEST EC EROSION CONTROL 0 DH DEEP HOLE =901 -PROPOSED CONTOUR PROPOSED SPOT ELEV. x99.9 EXISTING SPOT ELEV. ----90--- EXISTING CONTOUR NOTES 1. ALL ELEVATIONS REFER TO NAIL SET IN TREE, SEE PLAN FOR BENCHMARK LOCATION 2. ALL CONSTRUCTION SHALL CONFORM TO 310 CMR 15.00, TITLE V AND THE REGULATION OF THE TOWN'S BOARD OF HEALTH. 3. THIS PLAN DOES NOT WARRANT OR IMPLY ANY SUBSURFACE SOIL CONDITIONS OTHER THAN THOSE OBSERVED AT THE IMMEDIATE TEST PIT LOCATIONS. IF UNSUITABLE MATERIAL IS ENCOUNTERED. ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. 4. ALL TANKS, D -BOXES, AND CHAMBERS SHALL BE SET LEVEL AND TRUE TO GRADED ON A MECHANICALLY COMPACTED STABLE BASE. 5. AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED TO MINIMIZE EROSION. THE AREA OVER THE SYSTEM SHALL BE GRADED TO A MINIMUM OF 2% SLOPE TO PROVIDE POSITION SURFACE DRAINAGE. 6. THE ORIGINAL TOPOGRAPHIC SURVEY AND PLAN WERE DONE BY BORDERLAND ENGINEERING. 7. THIS PLAN SHALL NOT BE USED FOR THE REPRODUCTION OF PROPERTY LINES, NOR SHALL IT BE USED AS A MORTGAGE PLOT PLAN OR TITLE SURVEY. CONFORMANCE TO LOCAL BYLAWS SHALL BE DETERMINED BY THE OWNER PRIOR TO CONSTRUCTION. 8. THE OWNER IS RESPONSIBLE FOR THE DETERMINATION OF THE LOCATIONS OF ALL BURIED UTILITIES. 9. FOR PROPER PERFORMANCE, THE SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND PUMPED WHEN THE TOTAL DEPTH OF SOLIDS EXCEEDS 1/4 THE LIQUID DEPTH OF THE TANK. 10. ANY ALTERATIONS MUST BE REPORTED TO THE DESIGN ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 11. THE SYSTEM MUST BE INSPECTED DURING CONSTRUCTION BY THE BOARD OF HEALTH OR ITS AGENT AND THE DESIGN ENGINEER AND BE CERTIFIED BY THE DESIGN ENGINEER. 12. THERE IS NO RESERVE AREA. 13. ALL STONE USED IS TO BE DOUBLE WASHED STONE. 14. SEE 310 CMR 15.255 FOR FILL SPECIFICATIONS, SEE 310 CMR 15.247 FOR AGGREGATE SPECIFICATION. 16. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 17. THERE ARE NO WELLS WITHIN 100' OF THE SYSTEM. 18. AN EFFLUENT FILTER IS TO USED AT THE OUTLET END OF THE TANK. 19. THE EXISTING CESSPOOL SHALL BE PUMPED OUT JUST PRIOR TO CONSTRUCTION. THE NEW SEPTIC TANK WILL BE PLACED WHERE INDICATED ON THE PLAN. 20. SLOPES MUST BE STABALIZED POST CONSTRUCTION. 21. EXISTING 4 BEDROOM COTTAGES WERE DESIGNED FOR 4 BEDROOMS. (2 BEDROOMS/COTTAGE) 22. THE EXISTING SEPTIC SYSTEM IS TO BE ABANDONED ACCORDING TO TITLE 5 STANDARDS. 23. THERE WILL BE A POLY BARRIER AROUND THE ENTIRE SAS. SEE PLAN FOR LOCATION. SEE DETAIL ALSO. SEPTIC SYSTEM DESIGN PLAN CLIENT: LOCATION: DALE NUSSBICKEL 92 BREEZY POINT RD. YARMOUTH, MA. 02035 DATE: SEPT. 23, 2018 SCALE: 1" = 20' DESIGNED BY: TCR DRAWING NO.. 1 OF 2 JOB NO: CHECKED BY: JCS # DATE REVISION DESCRIPTION TCR JCS 1 10/15/18 ADD I A SYSTEM TCR JCS 2 12/9/18 REMOVE I/A SYSTEM TCR JCS Ad Y� LOCUS MAP Scale: NTS LOWEST GRADE EL. AROUND THE WALL IS 4.5± NOTE THAT THE FORCE MAIN WILL GO UNDER THE RETAINING WALL. AT INVERT EL. = 1.08 HEAD FEET U.S. GAL. 25 50 75 100 125 150 PER MIN. PUMP SYSTEM NOTES AND SPECIFICATIONS. 1. PUMP DESIGN INFORMATION PUMP: BARNES SE 411 OR SIMILAR, SINGLE PHASE, 0.4 HP 4.12" IMPELLER, 2 INCH DISCHARGER. STATIC HEAD: 2.8' DYNAMIC HEAD:11.0' TOTAL DYNAMIC HEAD:13.8' PROPOSED DISCHARGE RATE:85 GPM± T.D.H. :14.8' PUMP WILL HANDLE 1 1" SOLIDS FLOW VELOCITY: 6 F.P.S. ± FLOAT CONTROL ELEVATIONS OVERRIDE SWITCH: BOTH PUMPS ON: .35 ALARM ON:.50 LEAD PUMP ON: -.65 BOTH PUMPS OFF: -2.41 1. PUMP SHALL DELIVER MINIMUM OF 75 GPM AT 13.8 FEET T.D.H. 2. PUMPS SHALL BE INSTALLED ON STAINLESS STEEL SLIDE RAIL SYSTEM WITH QUICK DISCONNECT FEATURE. 3. PUMP CONTROL SHALL BE PRESSURE ACTIVATED LINEAR CONTROL SWITCH ATTACHED DIRECTLY UNDER ACCESS HATCH. 4. PUMP SYSTEM SHALL BE INSTALLED AND TESTED WITH WATER PRIOR TO FINAL APPROVAL OR DISCHARGE OF SANITARY WASTE. 5. PUMP ALARM SYSTEM SHALL BE ON A SEPARATE CIRCUIT, ISOLATED FROM PUMP ELECTRICAL SYSTEM. 6. EACH CYCLE PUMPS ± 440 GALLONS WASTE WATER TOTAL RUN PER CYCLE = ± 6.0 MINUTES CYCLES PER DAY = 1.5± 7. ALL ELECTRICAL COMPONENTS SHALL BE HARD -WIRED TO PANELS. NO JUNCTION BOXES SHALL BE USED. 8. NUMBER OF DOSING CYCLES PER DAY = 1.0± 9. THE ALARM PANEL SHALL BE INSTALLED IN THE CLOSET. 10. THE DESIGN POINT IS 70 GPM± FOR A TOTAL DYNAMIC HEAD OF 13.8. 2"x 2"x 4' WOOD STAKE OR APPROVED EQUAL-, �V PLACE 4" OF FABRIC--/// ABRIC III 1' (MIN.) ALONG TRENCH AWAY 111 FROM PROTECTED AREA, BACKFlLL AND TAMP NOTES. 1. FILTER CLOTH SHALL BE FASTENED SECURELY TO POSTS WITH WIRE TIES OR STAPLES AND POSTS SHALL BE PLACED EVERY 10 FEET. 2. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY 6 INCHES AND FOLDED. 3. ENTRENCH SILT FENCE AT LEAST 6 INCHES. 4. INSPECTIONS SHALL BE FREQUENT AND REPAIR OR REPLACEMENT SHALL BE MADE PROMPTLY AS NEEDED, OR WHEN SEDIMENT ACCUMULATES TO HALF THE HEIGHT OF FENCING. EROSION CONTROL SILT FENCE DETAIL N.T.S. PUMP DETAIL 3 -GATE PUMPS FXNIOF SNED GRADE ONE CO MUL BE gLOCK GRADE 1360 LOWEST GRADE EL. AROUND THE WALL IS 4.5f �- -1/2" HANDLE r END VIEW OF A C-4 CULTEC PANEL 18" FILTER / -CARTRIDGE FILTER f GASKET 2" PILE CAP SAND OVERDIG 146' LONG 40 MIL. "RUFCO 4000B" LINEAR LOW DENSITY POLYETHYLENE BARRIER FIRST COURSE OF BLOCK IS TO BE SET BELOW GRADE THE POLY BARRIER WILL BE WRAPPED AROUND THE ENTIRE PERIMETER OF THE SAS WHERE THE 5' SAND OVERDIG MEETS THE WALL. (SEE PLAN VIEW) POLY BARRIER AND BLOCK DETAIL N.T.S. 4" SANITARY TEE 4" SEWER - - PIPE "-- -GAS BAFFLE ZABEL A1800 RESIDENTIAL SEPTIC TANK EFFLUENT FILTER FOR SINGLE FAMILY HOMES. (800) 221-5742 INSTALLATION: FITS ANY 4" SANITARY TEE AND SEWAGE PIPE USED AS A SEPTIC TANK OUTLET BAFFLE. EXTEND SEWAGE PIPE AT LEAST ONE INCH BELOW BOTTOM OF FILTER CARTRIDGE GASKET. 8' LONG PLAN VIEW OF A C-4 CULTEC PANEL IoOW noY Y W D MMon MW oImmemo I" SI SIDE VIEW OF A C-4 CULTEC PANEL 4' WIDE 5'-4" 9,_0. TOP VIEW WIGGIN �f •'PRECAST III RISER TO GRADE WITH METAL MANHOLE COVER SUPPLIED WITH NEMA4X JUNCTION BOX JUNCTION BOX WILL BE OUTSIDE OF THE PUMP CHAMBER. THE JUNCTION BOX WILL BE IN A SEPARATE IRRIGATION BOX. A PRESSURE TRANSDUCER IS NEEDED FOR DUPLEX PUMPS e AS WELL AS A DUPLEX PANEL. a ww .pr 2' PVC STUB 2' UNI❑N • • BALL VALVE 2' CLEAN-OUT 5'=7• EL.= .50 (6") 1 b ° EL.= .35 4.2" a (❑PTIONALEL.= -.65 (- .8" ALARM LAG PUMP PUMP PUMP pFF 1/4' DIAMETER WEEP HOLE 6' ON ON (TYP 6') u 11 IN I e: EL.= -2.91 WA 2" SECTION VIEW\ -2# BALL CHECK VALVE TAPER BARNES SE411 OR EQUAL 1000 GALLON WATERPROOF PUMP CHAMBER DUPLEX PUMP PACKAGE NOTES: 1. CONCRETE: 5,000 PSI MINIMUM AFTER 28 DAYS. 2. CONSTRUCTION OF PUMP CHAMBER CONFORMS WITH DEP TITLE 5 REGS, 310 CMR, SECTION 15.226. 3. ALL REINFORCEMENT PER ASTM C1227. 4. JOINT SEALED WITH BUTYL RESIN. 5. DESIGNED FOR H-20 LOADING. 6. PUMPS, FLOATS AND PIPE INSTALLED IN CHAMBER, FLOAT ELEVATIONS SET UPON REQUEST. 7. SUPPLIED WITH PUMP CONTROL PANEL W/ALARM. 8. LAG & ALARM FLOATS CAN BE SWAPPED OR COMBINED INTO ONE FLOAT. TOWN OF YARMOUTH REQUIREMENTS: 1.) SURVEYOR TO STAKEOUT LOCATION OF WALL. 2.) ENGINEER TO INSPECT OVERDIG. 3.) ENGINEER TO INSPECT WALL FOOTING. 4.) ENGINEER TO INSPECT S.A.S. & PUMPS. BUOYANCY CALCULATIONS: WEIGHT OF PUMP CHAMBER AND SOIL ABOVE IT: 38,287 Ib± WEIGHT OF WATER DISPLACED BY THE PUMP CHAMBER: 18,7201b.± SINCE 38,2871b. > 18,7201b. IT IS O.K. WEIGHT OF THE SEPTIC TANK NEGLECTING THE SOIL ABOVE IT: 20,1001b.± WEIGHT OF WATER DISPLACED BY THE SEPTIC TANK: 18,6701b.± SINCE 20,1001b. . 18,6701b. IT IS O.K.