Loading...
HomeMy WebLinkAboutEngineered Plans - 2019.6"oUs EXISTING SEPTIC TANK (SEE NOTE 13) TOP OF TANK, EL.=96.661- INV. (OUT)=95.31- EXISTING S.A.S. TO BE REMOVED (SEE NOTE 11) PROPOSED S.A.S. 2-500 GALLON CHANMBERS SURROUNDED W/4' STONE OWNER OF RECORD GROSSMAN, DAVID A GROSSMAN, ROBIN F P.O. Box 406 CENTERVILLE, MA 02632 ---56-- EXISTING CONTOUR X 100.98 EXISTING SPOT GRADE —W EXISTING WATER SERVICE —G— EXISTING GAS SERVICE —e. 1-1-.-W— OVERHEAD WIRES SCALE TEST PIT JOB. NO. BENCHMARK I LEGEND I GENERAL NOTES: N L G LOCUS Neo�hec i v o. fi hoker Hou �z se Rd p Qa�r GSkipper Ln Early Red Berry Ln White Rock Rd LOCUS MAP NOT TO SCALE 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER, 4: ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. 13. IF SEPTIC TANK IS FOUND TO BE DEFECTIVE DURING INSTALLATION, IT SHALL BE REPLACED WITH A NEW 1500 GALLON SEPTIC TANK. 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. PARCEL ID: 115-49.1 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 2 SCOOP CIRCLE, YARMOUTH PORT, MA Prepared for: David Grossman, P.O. Box 406, Centerville, MA 02632 Engineering by: Surveyring by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 195-19 12 West Crossfield Road Forestdole, MA 02644 2854 Cranberry Hwy. E.Wareham, MA 02538 PATE CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 5/18/19 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE T.O. F. =105.6± - F.G. EL.=99.6± EXISTING F.G. EL.=99.3± 1 4" 48" LIQUID LEVEL ADD GAS BAFFLE PROPOSED D -BOX INSTALL RISER & COVER SET TO 6" OF GRADE F.G. EL.=98.0± L=7, L=8' ® S=1% (MIN.) ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC INV.=94.80 J PROPOSED -INV.=95.30 D BOX (SEE NOTE 2) 3 OUTLETS H-10 RATED NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED 310 CMR 15.405(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA NOTE: TO PREVENT' BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=95.0 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT I r F.G. EL.=97.8± MAINTAIN 2% SLOPE INV.=94.63 4' 4.8' 4 EFFECTIVE WIDTH = 12.8' INV.=94.50 TOP CONC. ELEV.=95.3± BREAKOUT ELEV.=95.00 INV. ELEV.=94.50 BOTTOM ELEV.=92.50 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. BOTTOM OF TEST PIT, EL.=86.2 S.A.S. SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .i4 uru/�)r- EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: .............................................................. SCALE N.T.S. 471.2 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD -2- LAYER OF 1/8- TO 1/2 - DOUBLE /2"DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) 4' 2 x 8.5'=27.0' 4' r EFFECTIVE LENGTH = 12.8' 3/4" TO 1-1/2" DOUBLE WASHED STONE SOIL LOG DATE: MAY 15,; 2019 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: PHIL RENAUD RS HEALTH AGENT ELEV. TP DEPTH 97.2 A 0 96.7 LOAMY SAND 1 OYR 4/1 6„ B II 4" KNOCKOUT LOAMY !SAND Prepared for: David Grossman, P.O. Box 406, Centerville, MA 02632 20" DIA. COVER 10YR 5/8 SCALE N.T.S. 95.2 JOB. NO. 195-19 DATE 5/18/19 i SHEET N0. 2 Of 2 N-P-ERC 30"/48" F -M SAND 2.5Y 7/3 86.2 132" NO GROUNDWATER ENCOUNTERED PERC RATE <2 MIN./INCH (HOUSE(#2) ;2\SO�ECK�� I S�. 9 9 � %9\ 6 M PROPOSED S.A.S:% ap S.A.S. LAYOUT =Nil � \ ►_1t-frllt-tt-It-lt-It=lt-1 t_1t-f � \ t�1 t�1 1�1 til t-1 t�1 til t�1 t�1 t-1 t�1 t�ft�lt�lt�lt�lt.lt�lt�lt�l=til • 500 GALLON CAPACITY, H-10 LOADING CHAMBERS 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 2 SCOOP 4" KNOCKOUT MA Prepared for: David Grossman, P.O. Box 406, Centerville, MA 02632 20" DIA. COVER Surveyring by: JC Engineering, Inc. 2854 Cranberry Hwy. E.Woreham, MA 02538 (508) 273-0377 SCALE N.T.S. 4" KNOCKOUT0 / 4" KNOCKOUT 4" KNOCKOUT JOB. NO. 195-19 DATE 5/18/19 500 GALLON CAPACITY, H-10 LOADING CHAMBERS 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 2 SCOOP CIRCLE, YARMOUTH PORT, MA Prepared for: David Grossman, P.O. Box 406, Centerville, MA 02632 Engineering by: Engineering Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Surveyring by: JC Engineering, Inc. 2854 Cranberry Hwy. E.Woreham, MA 02538 (508) 273-0377 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 195-19 DATE 5/18/19 CHECKED P.T.M. SHEET N0. 2 Of 2