Loading...
HomeMy WebLinkAboutReview Checklist ' ‘ r'").0 "7 , ' , ilf-" -77- TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Ay /62.04 Location: A.M. ‘ 7 Lot , Zone of Contribution: In - Commercial: Residential: Street: / 7 i, Village: /1- ��i�!�1 Floor Plan: r.� #Bedrooms: Owner: i/0 GM 4/f 0 Installer: 7 Address: Phone: Phone: / ,� j ll Builder: l,-Engineer: . Q A146 At. /' 7 � Address: Phone: Ii� � W �, 1 - Phone: / ;_ _D c L N/Ale.: )iNO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table L1 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 1/4.------ 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: CdtatS 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �1 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: .i- 11.Tank/leaching minimum 10 ft from property line Var.: L---'12. System meets all other setback requirements Var.:///46Y Aiveicr/za/f _ 'E. '13.Uses adjustment for maximum high groundwater Var...:..., 14.Leaching set 4-5 ft above adj.water or botto of test hole ar.: ✓ 15. System not in top or subsoil(A,B horizons)o 5'remov - Wed/- 4,( d I l.'T 16.Proposed contours are suitable (/*" 17. System meets slope requirements-min. 1/8", ' "preferred t..--'" 18. System meets breakout requirements PVC liner: Wall: t_..--. 19. Specified tee sizes are proper, gas baffle on outlet tee �i 20. Sewage is under 10,000 gpd for parcel c___---"' 21.No garbage disposal Lam• 22. System adequately sized for its intended use LJ 23.Minimum 6"stone or compacted below tank and dbox �--. 24.Manhole covers within 6"of grade,pump chamber cover to grade v _.-- 25. 25.Inspection port on plastic chambers/leach field Lam• 26.Electrical permit for pump chamber/Separate meter for duplexes r- 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size .i- 28. Septic tank/pump chamber to be factory waterproofed ..---' 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: co 1 u er l: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 33.H-20 loading is subject to vehicular traffic,groundwater -...._....---- 34. _.✓34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house ..._..----- 36. /36.Deed Restriction required max. #bedrooms: max. flow: gpd .l- 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03