Loading...
HomeMy WebLinkAboutEngineered Plan - 2019COGSWELL j PATH LOCATION MAP LOT 87 (8,786 SF) ASSESSORS MAP: 76 PARCEL: 86 PLAN BOOK: 220, PAGE: 149 SENCHMARK AT CORNER OF CONC. PATIO AT PAINT MARK ELEVATION = 104.20 109 10f 108 107 -_ 20" oak j 106-_. 33.5' _ L �� . LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GALWAY SEPTIC TANK: 330 GAL / DAY x2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 2' OF STONE AROUND SIDES AND 4' AT ENDS (8.8'x 33.5'x 2') SIDE AREA: (8.8'+ 33.5') x 2 x 2 = 169 SF (0.74) =_125 GAUDAY BOTTOM AREA: 8.8'x 33.5'= 295 SF (0.74) = 218 GAL/DAY CAPACITY = 343 GAL/DAY 102- N 02__._N 82°22'26" E -- L ,103 0 0 r i I 107 106 105 Tie ret. wales-- 1 104 GARAGE PAVED DRIVE ,/fire pit 1 I O CONIC. J i PATIOEYISTING NEROOM LING th-1I • . 10' top Ind =104.72 j 14' 105 Z Shed 0 o� �-co M19-31 1 j min KEY: SH EXISTING CONTOUR: - - - - 0 m LOCUS PROPOSED CONTOUR: ............. SPOT ELEVATION: •�^- Invert =102.47 EXISTING 25.5 cp PROPOSED SPOT ELEVATION: 25.5 y :xiv,0aks v N TEST HOLE: G ma: 20' / I UTILITY POLE: -O- FENCE LINE: 4I O.H.W.- .H.W.- RETAHYDINING WALL: m COGSWELL j PATH LOCATION MAP LOT 87 (8,786 SF) ASSESSORS MAP: 76 PARCEL: 86 PLAN BOOK: 220, PAGE: 149 SENCHMARK AT CORNER OF CONC. PATIO AT PAINT MARK ELEVATION = 104.20 109 10f 108 107 -_ 20" oak j 106-_. 33.5' _ L �� . LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GALWAY SEPTIC TANK: 330 GAL / DAY x2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 2' OF STONE AROUND SIDES AND 4' AT ENDS (8.8'x 33.5'x 2') SIDE AREA: (8.8'+ 33.5') x 2 x 2 = 169 SF (0.74) =_125 GAUDAY BOTTOM AREA: 8.8'x 33.5'= 295 SF (0.74) = 218 GAL/DAY CAPACITY = 343 GAL/DAY 102- N 02__._N 82°22'26" E -- L ,103 0 0 r i I 107 106 105 Tie ret. wales-- 1 104 GARAGE PAVED DRIVE ,/fire pit 1 I O CONIC. J i PATIOEYISTING NEROOM LING th-1I • . 10' top Ind =104.72 j 14' 105 Z Shed 0 o� �-co M19-31 1 j min SH ST •�^- Invert =102.47 cp y :xiv,0aks o / 20' O.H.W.- .H.W.- AREA OF AREA RGE c � , � PINE TREES / 12" pine 100.00' S 82°22'26" W j / 04 103 102 x 103.4 GARAGE SEPTIC SYSTEM SECTION 104.72 TOP OF ° FOUNDATION 102.47 1/4" per ft ELEV. a ° 102.22/ ELEV. 1500 GAL SEPTIC TANK 6" OF STONE UNDER OR ECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN COVERS WITHIN OF FINISHED GR MAX. C 1/8"Der ft � COVER (V MIN) )1_97 7r .r., 1/8" per ft D -BOX (6" STONE UNDER) - GAS BAFFLE AT OUTLET TEE ELEV TEST HOLE LOGS BED BED ENGINEER: THOMAS MCLELLAN, P.E. LIVING ROOM ROOM ROOM WITNESS: AMY VON HONE, R.S. DATE: 6-20-19 PERCOLATION RATE: < 2 MIN/IN DINING BED ROOM ROOM i KITCHEN BATH ] EXISTING FLOOR PLAN Yarmouth Health Department PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT ,-- ELEV.= 102.35 111° °°°I'IJ99.52 4 <--> ELEV. -8.8'x 33.5' > 3 - 500 GALLON CHAMBERS WITH 2' OF STONE AROUND SIDES AND 4' AT ENDS (8.8'x 33.5'x 2' EFFECTIVE DEPTH) TH-1 105.5 0/A HORIZON ELEV. LOAMY SAND 10YR 4/1 104.7 B HORIZON PERC AT 36" LOAMY SAND 10YR 5/8 101.0 C HORIZON MEDIUM SAND 2.5Y 7/4 138"1 1 94.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST T OF PIPE OUT OF D -BOX TO BE SET LEVEL. j 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS, ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. CONTRACTOR TO VERIFY IF OTHER CESS POOLS EXIST. IF SO, PUMP AND FILL WITH SAND OR REMOVE. 14, D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. �-- Y ague Date or l; + E qS J. <1C- i�c ivik,,N PO.36471 SITE PLAN LOCATION: 79 WEBBERS PATH, W. YARMOUTH, MA PREPARED FOR: PAUL BAYER I DATE: 6-25-19 SCALE: 1" = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048